Description:

The Signal-VK-4P device is intended for centralized and autonomous protection of closed heated and unheated premises (shops, banks, pharmacies, institutions, garages, hangars, warehouses and other premises) from unauthorized intrusions and fires by monitoring the state of four alarm loops ( AL) and issuing notifications via four outputs to the monitoring station control panel.

Peculiarities:

  • Control of four loops allows replacing a group of single-loop devices at the facility, organizing multi-line security.
  • Control of changes in the resistance of the security loop in the range from 2 to 11 kOhm at a rate of up to 10% per 1 hour relative to the current value.
  • Control of changes in the resistance of a fire alarm loop in the range from 2 to 6 kOhm.
  • The device remains in standby mode in case of loop violation in security mode for up to 50 ms and in fire loop mode up to 250 ms.
  • Various modes of operation of remote light and sound annunciators, depending on the activation of a security or fire alarm loop.
  • Formation of a failure notification on the monitoring station3 in the event of a fire alarm loop failure.

The device provides:

  • Possibility of switching on current-consuming security and fire detectors of the type "Window", "Photon", "Volna-5", DIP and the like into the alarm loop;
  • Possibility of power supply for detectors such as "Echo", "Photon", "Wave", "Peak" and others;
  • Setting the mode "without the right to shutdown" by jumpers to provide the functions of "silent" alarm of the third AL and the fire loop of the fourth AL;
  • Setting the mode of switched off sirens, annunciators and indicators using an external cipher device;
  • Setting a delay of 30 seconds for turning on the siren after the device issues an alarm message on ШС1;
  • Possibility of autonomous protection when powered from the AC mains with the issuance of signals to the external light network, light and sound direct current sirens, built-in light indicators displaying the state of four AL, and to the built-in sound signaling device.

Device connection diagram:

A1- device "Signal VK-4P";
HL1- light indicator of direct current type "Mayak" (12 V);
R1 ... R3- resistor C2-33N-0.5-8.2 kOhm 5%;
R4- resistor C2-33N-0.5-8.2 kOhm 5% (in security mode);
R4- resistor C2-33N-0.5-4.7 kOhm 5% (in fire mode);
I1, I3, I5, I7- detectors with normally closed contacts;
I2, I4, I6, I8- detectors with normally open contacts or detectors of the "Window", "DIP", "Volna-5", "Photon" types.

Characteristics of the Signal-VK-4P device:

Alarm loops:
quantity, pcs 4
maximum line resistance, kOhm 1
minimum line leakage resistance, kOhm 20
resistance of the remote resistor in security mode, kOhm 8,2
resistance of the remote resistor in fire mode, kOhm 4,7
"Alarm" notification to the monitoring station opening of the contacts of the executive relays
Fire notification to the monitoring station closing of contacts of executive relays
Maximum switched by contacts of executive relays:
current, mA
50
voltage, V 72
Power supply of detectors from the device:
voltage, V
10,8-13,2
current, mA 100
Power consumed from the AC mains without a network siren, VA 30
Back-up power supply of the device (from a direct current source):
voltage, V
12-18
current (including the power supply of the detectors) in standby mode, mA 300
Sounder duration, min 2
Maximum power of the remote light network annunciator, VA 60
Maximum power of the external DC sounder 12Vx0.6A
Maximum power of the external direct current light annunciator 12Vx0.05A
Operating temperature range, С from -30 to +50
Overall dimensions, mm 210x170x85
Weight, kg 2

Size: px

Start showing from page:

Transcript

1 DEVICE ALARM-CONTROL ALARM-FIRE "SIGNAL-VK1", "SIGNAL-VK1" isp.01 ADSDR RE Operation manual 2003

2 Contents Introduction 3 1 Description of the device Purpose of the device Characteristics Completeness Design and operation of the device Marking Packaging 15 2 Intended use Preparing the device for use Preparing for work Using the device 18 3 Maintenance 19 4 Routine repair 21 5 Transportation and storage 22 6 Manufacturer's warranties 23 7 Certification information 23 Appendix A Overall and mounting dimensions 24 Appendix B Functional electrical diagram 25 Appendix C Instrument electrical connection diagram 26 Appendix D Instrument operability check diagram 27 8 Acceptance and packing certificate 28 2

3 This operating manual is intended to study the principle of operation and operation of the control and monitoring devices for security and fire control panels "Signal-VK1" and PPKOP / 01 "Signal-VK1" isp Description of the device 1.1 Purpose of the device -VK1 "and PPKOP / 01" Signal-VK1 "isp.01, (hereinafter - the device), is intended for centralized and autonomous protection of shops, cash registers, banks, pharmacies, institutions and other objects from unauthorized intrusions and fires by monitoring the state of one alarm loop (AL) with security, fire or security-fire detectors included in it and issuing notifications to the centralized monitoring station (CMS) using a relay output about violation of the AL and triggering of detectors; on-site control of internal light signaling devices, external sound and light signaling devices; control of taking / removing the device using a built-in magnetically controlled contact; providing power supply to the detectors at the "+12 V" output; control of opening the device case using a switch; ensuring the change of operating parameters using removable jumpers The device is designed to be installed inside the protected object and is designed for round-the-clock operation The device is designed to work together with the centralized monitoring consoles "Neva-10", "Neva-10M", "Center-M", "Center -KM "," Progress-TS "," Phobos ", AWP" Phobos ", etc. The AL of the device can include: - magnetic contact detectors IO102-2, IO102-4, IO102-5, IO102-6, sensors such as "Foil", "Wire"; - shock-contact detectors "Window-6"; - detectors of optical-electronic, ultrasonic and radio wave types "Foton-6", "Foton-6A", "Foton-6B", "Foton-8", "Foton-8A", "Foton-8B", "Foton-9 "," Foton-Sh "," Foton-SK "," Foton-SK2 "," Astra-MS "," Argus-2 "," Argus-3 "," Echo-3 "," Showcase "," Echo -3 "," Echo-A "," Wave-5 "and the like; - detectors of acoustic type "Arfa", "Glass-1", "Glass-2-1", "Glass-3"; - detectors of the capacitive type "Peak"; - combined security detectors "Sokol-2"; - detectors of piezoelectric type "Gran-2", "Shorokh-1-1"; - output circuits of control and monitoring devices; - heat fire detectors "IP 101-2", "IP 103-5", "IP103-7", etc. batteries with the issuance of signals to external light and sound annunciators and a built-in indicator. The transmission of notifications to the monitoring station about an alarm or fire is carried out using the relay contacts. Fault notification transmission is carried out using the "open collector" (OK) output.

4 with a nominal voltage of 12 V and a capacity of 1.2 A h or an external standby source of direct current with a voltage of (12 + 2.2-0.6) V installation inside a guarded facility and is designed for round-the-clock operation The design of the device does not provide for its use in conditions of exposure to aggressive environments, dust, as well as in fire-hazardous rooms. By the type of maintenance, the device is classified as a product with periodic maintenance. The average total operational duration of maintenance is not more than 0.15 hours per month The device is designed for operation in the following conditions: - the range of operating ambient temperatures from 243 to 323 K (from minus 30 to C) (without a battery) and from 263 to 323 K (from minus 10 to +50 o C) with a rechargeable battery. - relative humidity at an ambient temperature of 298 K (+25 o C) up to 98%; - vibration loads in the range from 1 to 35 Hz with a maximum acceleration of 0.5 g.In terms of protection against environmental influences, the device has an ordinary version according to OST The device belongs to single-function, repairable, repaired and serviced products of group II, type 1 according to GOST. work - exponential An example of recording the designation of the device when ordering it and in the documentation of other products is given in Table 1. Table 1 Designation OKP code Example of recording when ordering a version of the ADSDR ADSDR Control and fire alarm device PPKOP "Signal-VK1" PPKOP / 01 "Signal-VK1" isp.01 АЦДР ТУ 1.2 Characteristics General requirements The device complies with the requirements of GOST R, and a set of design documentation according to АЦДР Component parts have passed the incoming inspection in accordance with GOST in accordance with the list approved in accordance with the established procedure Basic parameters and dimensions Device keeps a slave operability in the range of supply voltages from 187 to 242 V when powered from an alternating current with a frequency of (50 ± 1) Hz The device remains operational in the voltage range (11.6 ... 14.2) V from a built-in rechargeable battery with a nominal voltage of 12 V and with a capacity of 1.2 Ah in the event of a decrease in the mains voltage below 187 V. Power supply of the device 4

5 can also be carried out, in the event of a decrease in the mains voltage below 187 V and the absence of a built-in storage battery, from an external backup DC source with a voltage of (12.0 + 2.2-0.6) V. continuous mode, and when performing n in flashing at a frequency of 1 Hz. When the voltage on the battery drops below 10.2 V and there is no mains voltage, the "PIT" indicator turns off. If the mains voltage is present and the voltage on the battery drops to 11.6 10.2 V, the external DC sounder is turned off (if it was turned on). Alarm "no more than 15 V A The current consumed by the device from a backup source, excluding the power supply of active detectors and an external light annunciator, in standby mode when monitoring an alarm loop, no more than 30 ma; in the "Alarm" mode 0.7 A (when the siren is on). The current consumed from the backup source, taking into account the power supply of active detectors, no more than 90 ma when monitoring the security loop in standby mode and no more than 0.7 A (with the siren on) in the "Alarm" mode Number of alarm loops connected to the device (informational capacity) - one The information content of the device, in accordance with GOST, is given in Table 2. Table 2 Designation of the ATSDR device Types of notifications "Norma" in the loop at the monitoring station "Alarm" in the loop at the monitoring station "Norma" in the loop at the built-in indicator "AL" "Alarm "in AL to the built-in AL indicator" Norm "to the external DC light annunciator" Alarm "to the external DC light annunciator" Alarm "to the external DC sounder" Network OK "- to the built-in PIT indicator" Trouble networks "- to the built-in indicator" PIT "" Power failure "to the built-in indicator" PIT "" Fire "in the loop at the monitoring station" Fire "in the loop to the built-in indicator" AL " star DC alarm signaling device "Fault" in the AL to the "FAILURE" output "Fault" in the AL to the built-in AL indicator and the external DC light annunciator "Fault" in the AL to the external DC sounder 5

6 The device provides commutation of remote light and sound annunciators and a FAULT output in accordance with Table 3. Table 3 Designation of the ATsDR device with installed Types of annunciators and external devices Switched current in circuits, A 12 V Remote audible constant current 0.6 Remote light constant current 0 , 05 with battery Output FAILURE 0.1 ATSDR without battery External sound constant current 0.06 External light constant current 0.05 Output FAILURE 0, The device provides operability in the following operating modes: - removed (the state of the AL is not analyzed); - transient (violation of the loop is not remembered); - duty officer (control loop); - alarms (loop violation is memorized); - malfunction (short circuit or open loop. Loop violation is not remembered); - fire (loop violation is memorized) Depending on the position of the removable jumpers "1", "2" and "AKK" the device provides functions in accordance with those indicated in Table 4. Table 4 "1" "2" AL Siren activation delay yes yes Burglar , 30 sec with automatic recapture and saving the alarm indication yes no Burglar, 30 sec with forced control no yes Burglary, 0 sec with forced control no no Fireman - "AKK" If jumpers "1" and "2" are installed in the burglar alarm mode, repeated violation of the AL leads to the repeated activation of the sounder for 2 minutes, while the indicator of the AL device and the light annunciator continue to glow with intermittent light. The sounder is activated with a 30 s delay. When jumper "1" is installed and jumper "2" is removed in the burglar alarm mode, when the control panel is in alarm mode, the restoration of the AL and its repeated violation does not lead to the activation of the sounder, while the sounder after the first violation of the AL is switched on with a delay of 30 s ... 6

7 When jumper "1" is removed, jumper "2" is installed in the burglar alarm mode when the control panel is in alarm mode, restoration of the alarm loop and its repeated violation does not trigger the sounder, while the sounder is activated immediately after the first violation of the alarm loop. When the jumpers "1" and "2" are removed in the fire alarm mode, the device switches to the "Fire" mode when heat or smoke fire detectors with normally closed contacts are triggered. The device switches to the "Fault" mode in the event of a short circuit or an open loop. When the "AKK" jumper is installed, the device does not analyze the battery condition and analyzes it with the jumper removed. Taking and removing the device is carried out using a built-in magnetically controlled contact. During the operation of the magnetically controlled contact, the "AL" indicator and the external light annunciator switch to a blinking mode with a frequency of 6 Hz. The device is also picked up automatically when power is applied. In this case, the monitoring station relay contacts are closed, and after 60 s, the AL indicator and the external light annunciator turn on in the continuous light mode. In the transient mode, for 60 s, the AL indicator and the external light annunciator turn on in the intermittent glow mode for 0.25 s and do not light for 1.5 s, indicating that the transition to the standby mode is in progress. Violation of the alarm loop in the transient mode is not remembered, however, the monitoring station indicator opens at the same time, and the "loop" indicator and the external light annunciator turn on in the intermittent light mode with a frequency of 1 Hz. Removal of the device is carried out by bringing a magnet to the actuation zone of the magnetically controlled contact, while the AL indicator turns off, the remote light and sound (if enabled) sirens, the monitoring station relay contacts open. mode depend on the state of the loop (armed or disarmed) as follows: - if the loop is disarmed, the "disarmed" mode is provided, the state of the loop is not analyzed, the alarm status indicator is off, the monitoring station relay contacts are open, the light and sound annunciators are disabled ; - after arming, the control panel provides a transitional mode (violation of the alarm loop is not memorized by the control panel, the "loop" indicator and the light annunciator indicate the state of the loop; s off) - if not violated, the monitoring station relay contacts are open, if the AL is violated, and closed, if the AL is not violated). If during arming the loop is initially violated for more than 60 s, then the transition mode continues until the loop is restored. After that, after 1 s, the device switches to standby mode. After the end of the transient mode, the "AL" indicator and the light annunciator light up continuously, the monitoring station relay contacts are closed, the device goes into standby mode; - if the alarm loop is violated in standby mode, the control panel goes into alarm mode with the "AL" indicator and light annunciator turning on in blinking mode, opening 7

8 contacts of the monitoring station relay, turning on the sounder for 2 minutes and staying in this mode until it is disarmed. With jumpers "1" and "2" installed in the burglar alarm mode, after turning off the sounder and restoring the alarm loop, the control panel goes into standby mode (automatic re-arming) after 60 seconds, the monitoring station contacts close, while the alarm indicator and the light alarm remain in flashing mode. A new triggering of the AL leads to the activation of the sounder for 2 minutes (if the mains supply is available and the battery is depleted, the device remains operational, but the siren will turn off when the minimum permissible voltage on the battery is reached), the opening of the monitoring station relay contacts, without changing the state of the AL indicator, and light annunciator. The sounder is activated with a 30 s delay. When jumper "1" is installed, jumper "2" is removed in the burglar alarm mode, when the control panel is in the alarm mode, the restoration of the alarm loop and its repeated violation does not lead to the activation of the sounder, while the sounder after the first violation of the alarm loop turns on with a delay of 30 s ... When jumper "1" is removed, jumper "2" is installed in the burglar alarm mode, when the control panel is in alarm mode, the restoration of the alarm loop and its repeated violation does not lead to the activation of the sounder, while the sounder is activated immediately after the first violation of the alarm loop. In all sub-modes of the security alarm, when the device is opened, the "Alarm" signal is generated, as when the sensor is triggered with normally closed or normally open contacts. violated) depend as follows: - within 15 s after turning on the power, the device provides a transient mode and does not remember violations of the loop; - after 15 s the device switches to the "Taken" state; - when a heat or smoke fire detector with normally closed contacts is opened, the device closes the monitoring station relay contacts, turns on the sounder in the "Fire" mode for 4 minutes, switches the "AL" indicator and the light annunciator to the blinking "Fire" mode; - when the loop is opened or closed, the control panel opens the FAILURE output, turns on the sounder in the "Fault" mode, turns on the "AL" indicator and the light annunciator in the "Fault" mode. When the loop is restored, the device switches to the "Taken" state; - when the device case is opened, the "Fault" signal is also generated; - to transfer the device to the "Taken" state from the "Fire" state, it is necessary to bring the magnet from the device kit into the zone of influence on the magnetically controlled contact. The device switches to the "Taken" state after 15 seconds. ± 0.6) in the "Alarm" or "Fire" mode when the siren is on. In case of power failure 8

9 alternating current, the "PIT" indicator is switched on in an intermittent mode of illumination with a frequency of 1 Hz. The device provides indication "PIT", which displays the state of the supply voltage of the device, and issues the following notifications to it: - "Network is normal" - the "PIT" indicator is on when the voltage in the AC network is more than 187 V; - "Mains failure" - the "PIT" indicator glows with an intermittent light with a frequency of 1 Hz in the absence of voltage in the AC mains; - "Power failure" - the "PIT" indicator is off when the voltage in the backup power supply circuit (battery) is less than (11.0 ± 0.6) V in standby mode and less (9.0 ± 0.6) in mode " Alarm "," Fire "and in the absence of voltage in the AC network. Duration of operation of the device from the built-in backup battery with a capacity of 1.2 A h without additional external consumers for at least 24 hours in standby mode and at least 3 hours in" Alarm "mode," Fire "When security and fire detectors are switched on in the AL, the device is in standby mode with the following AL parameters: 1) the resistance of the AL wires without taking into account the remote element - no more than 100 Ohm; 2) Leakage resistance between the AL wires or each wire and the "ground" - not less than 20 kΩ The device remains in standby mode if the AL is violated for less than 50 ms (250 ms - for the fire alarm mode) with the AL resistance (2 6) kΩ ± 10%, taking into account the resistance of the remote element, as well as with a slow change in the loop resistance in the above range at a rate of up to 10% per hour (only for the security alarm mode) The device switches to the "Alarm" mode when the resistance of the security loop leaves the range 6) lump ± 10% for a time of 70 ms or more, as well as with an abrupt change in the resistance of the security loop by 10% or more relative to the current value in the range (2 6) lump ± 10%. The device switches to the "Fire" state when the heat or smoke detector with normally closed contacts is opened (triggered). The device goes into the "Fault" state when the loop is opened or closed for a time of 300 ms or more (when the loop resistance increases by more than 50 kΩ or decreases to less than 100 ohms). AL voltage at the AL input no more than 14 V Ripple voltage in the AL - no more than 20 mV (effective value) The device provides power supply to active detectors with the following parameters: 1) supply voltage - (12 + 1.8-2.2) V; 2) consumed current - no more than 60 ma. The value of the ripple voltage at the power output of active detectors with a voltage of 12 V - no more than 20 mV (effective value) When powered from the mains, the device restores its operability after a short circuit (up to 60 s) of the power supply circuit of active detectors. I am

10 The device provides automatic switching of power to the built-in rechargeable battery in the event of a power failure and vice versa without issuing an alarm. The device of version 01 is supplied without a storage battery. up to 80 V and maximum current up to 50 ma The device is resistant to impulse noise induced in the AL with an amplitude of up to 300 V and a duration of up to 10 ms The device is resistant to electromagnetic interference in the AL in the form of sinusoidal voltage pickups with a frequency of 50 Hz and an effective voltage value up to 1 V The device does not give false notifications after exposure to external electromagnetic interference (EMF) of the second degree of severity in accordance with GOST R The radio interference generated by the device during operation does not exceed the values ​​specified in GOST R ambient temperature from 243 to 323 K (from minus 30 to +50 o C) and from 263 to 323 K (from minus 10 to +50 o C) for a device with a battery; 2) relative humidity up to 98% at 298 K (+25 o C); 3) vibration loads in the range from 1 to 35 Hz with a maximum acceleration of 0.5 g Time of technical readiness of the device for operation, after turning on its power supply, no more than 3 s with 2 at a frequency of blows from 80 to 120 per minute or blows; 2) temperature from 223 to 323 K (from minus 50 to C); 3) relative humidity (95 ± 3)% at 308 K (+35 0 С) Average time between failures in standby mode of operation - not less than hours, which corresponds to the probability of no-failure operation of 0.97 per 1000 hours Average recovery time during repair work - no more than 60 minutes Average service life of the device is 10 years. The device must replace the battery at least once every 5 years. more than 151 x 157 x 71 mm. ten

11 1.3 Completeness The delivery set of the device corresponds to that specified in Table 5. Table 5 Qty. to Designation Name version АЦДР Control and fire control device PPKOP "Signal-VK1" АЦДР Control and fire control device PPKOP / 01 "Signal-VK1" isp. 01 Spare parts set: Resistor ОЖО ТУ С2-33Н-0.5-4.7 kΩ ± 5% Magnet in the case Fuse inserts ОЖО ТУ ВПТ6-1 (0.16 А) АЦДР РЭ pcs pcs. 1 PC. 1 PC. 1 PC. 1 PC. 1 PC. 1 PC. Note Screw 1-4x GOST pcs. 3 pcs. Battery 12 V, 1.2 Ah 1 pc. - Supplied by separate order. Control and monitoring device, security and fire, PPKOP "Signal-VK1". Operation manual 1 copy 1 copy Note 1 Delivery of group spare parts kits is carried out under a separate agreement according to the spare parts list. 2 It is allowed to supply devices with a switching device "UK-VK" to ensure the possibility of control through the outputs to the light and sound annunciators (with the connection of an external power source) of circuits under 220 V AC voltage with a current of up to 0.8 A or up to 10 A 1.4 Design and operation of the device holes for fixing, with which the device is fixed on the wall in the working position. The electrical functional diagram of the device is given in Appendix B The electrical diagram of the device is given in Appendix C. The device consists of the following functional units: - connection unit; - input block; - rectifier; - voltage stabilizer 15 V; - keys 1, 2, 3; - voltage stabilizer 5 V; eleven

12 - processor; - coordination with AL; - setting the operating mode of the device; - battery emergency shutdown devices; - devices for recharging and matching with the battery; - control of taking and removing the device; - supply of backup power; - "Fault" output; - protection against opening; - indicators "AL," PIT "The connection node contains two blocks for connecting external conductors of the AC power supply, a direct current light annunciator, an alarm loop, a remote sounder, +12 V reserve, an actuator to the" Fault "output, monitoring station circuits and active detectors requiring a separate power source The input unit contains a mains fuse and a step-down mains transformer with a thermal fuse installed inside it The rectifier contains a bridge rectifier and a smoothing capacitor The +15 V voltage stabilizer contains an integral stabilizer, an output smoothing electrolytic capacitor and is designed to power active detectors, external light and sounder DC sounders Key 1 contains a low-power relay, a protective diode and a resistor that limits the current in the monitoring station circuit, and is designed to send an alarm signal to the monitoring station. contains a transistor switch, protective diodes and is designed to control the "AL" indicator and a remote DC light annunciator. The control action on key 2 is supplied from the processor Key 3 contains a transistor key and is designed to control a remote DC sounder. The control action is fed to key 3 from the processor The +5 V voltage stabilizer contains an integral stabilizer, two smoothing capacitors and is designed to power the processor and some consumers requiring a 5 V current source. to control the operation of the device The node for matching with the AL provides supply of +12 V voltage through the limiting resistor to the AL and transfers the voltage from the AL through a resistive divider to the analog input of the processor for further analysis. The unit for setting the operating modes of the device includes three removable jumpers "1", "2", "AKK" and is designed to change the current configuration of the device. The battery emergency shutdown device consists of an electronic key, and is designed to disconnect the battery when the voltage on it drops below the permissible level. The device for recharging and matching with the battery consists of current limiting resistor for recharging the battery and the matching diode. 12

13 The control unit for taking and removing the device consists of a magnetically controlled contact and is designed to control the device using a magnet; The back-up power supply unit is designed to connect a 12 V DC back-up power supply. The back-up power supply through a separating diode is connected to the +12 V circuit of the device. opening contains a limit switch and contacts for installing a removable technological jumper blocking the limit switch and is designed to switch the device into alarm mode when the case is opened. The device is supplied without a jumper.In the initial state, the external toggle switches S1 and S2 are open, the device is de-energized (Appendix B). When the toggle switch S1 is closed, a supply voltage of 220 V is supplied to the device. The device starts to work depending on the installed configuration using jumpers "1", "2" and "ACK": - "Normal" mode - with loop resistance (from 2 to 6) kΩ ± 10%, in security and fire mode; - "Alarm" mode - when the loop resistance is less than 1.7 kΩ or more than 5.4 kΩ in the security mode; - "Fault" mode when the loop resistance is less than 100 Ohm or more than 50 kΩ, in fire mode; - "Fire" mode when the loop resistance is more than 5.4 kΩ, but less than 40 kΩ in fire mode. In the "Normal" mode, the processor closes Key 1 and Key 2, thus turning on the built-in LED indicator, and Indicator (external constant current light annunciator). All indicators should be lit with continuous light. In the "Alarm" mode (in security mode), i.e. in case of violation of the normal state of the AL resistance (the value of the AL resistance is less than 1.7 kΩ or more than 5.4 kΩ), the processor opens Key 1, transmitting the Alarm signal to the monitoring station, switches the built-in AL indicator and the remote indicator light to intermittent mode glow with a flashing frequency of 1 Hz. In the "Fault" mode (in fire mode), that is, in case of violation of the normal state of the alarm loop (the loop resistance value is less than 100 Ohm or more than 50 kΩ), the processor opens the OK output, transmitting the "Fault" signal to the monitoring station, switches the indicator and light annunciator to intermittent lighting mode: 0.5 s on, 3.5 s off, turns on the sounder in the mode: 0.5 s on, 3.5 s off. When the normal state of the AL is restored, the processor switches to the "Normal" mode. In "Normal" mode, all indicators are solid. In the "Alarm" mode, the processor opens Key 1, transmitting the "Alarm" signal to the monitoring station, switches all indicators to intermittent light with a blinking frequency of 1 Hz and closes Key 3, including the Siren (remote sounder of constant current) for 2 minutes. Moreover, depending on the state of the jumpers "1" and "2", the external sounder is switched on immediately upon the appearance of the "Alarm" mode or with a delay of 30 s, or the device is automatically re-armed after the siren ends. 13

14 In the "Fire" mode (with the jumpers "1" and "2" removed), the indicator and light annunciators glow with an intermittent light with a frequency of 1 Hz. The sounder operates in the mode: 0.5 s on, 0.5 s off, for 4 minutes. The monitoring station relay contacts are closed, transmitting the "Fire" signal. In the "Fault" mode (with the jumpers "1" and "2" removed), the indicator and the light annunciator light up in the mode: 0.5 s on, 3.5 s off. The sounder operates in the mode: 0.5 s on, 3.5 s off. The OK output opens giving a "Fault" signal. When the normal state of the loop is restored, the device switches to the "Normal" mode. When the "Alarm", "Fire" mode occurs, the processor memorizes it and does not return the control panel to the "Normal" mode even after the AL returns from the "Alarm", "Fire" mode to the "Normal" mode. This state of the processor can be removed only by acting on the magnetically controlled contact or by completely disconnecting the supply voltage (with disconnecting the built-in battery). The device can operate from a 12 V backup source connected to the connection node or from a built-in battery. Power is turned on from the backup source with toggle switch S2 (see Appendix B). In the absence of mains voltage, the "PIT" indicator turns into a blinking mode with a frequency of 1 Hz. Otherwise, the operation of the device is the same as with the mains supply voltage. 1.5 Marking The marking of the device corresponds to the set of design documentation and contains: 1) the trade mark of the manufacturer; 2) the symbol of the device; 3) serial number; 4) the mark of conformity; 5) quarter and year of manufacture (last two digits) The marking of the external terminals of the device corresponds to the electrical schematic diagram of the device. Next to the mains voltage connection node, the rated voltage of the mains supply is 220 V The method of application and the quality of the inscriptions and designations provide sufficient contrast to allow reading the inscriptions under normal lighting during the entire service life of the device. ) the trademark of the manufacturer; 2) the symbol of the device; 3) the number of devices; 4) month and year of packaging; 5) serial number; 6) signature or stamp of the person responsible for packaging. The marking of the shipping container corresponds to the drawings of the manufacturer, contains: the trademark of the manufacturer; product designation; number of products; gross weight; month and year of packaging; has 14

15 manipulation signs: "Caution, fragile!", "Afraid of dampness", "Top, do not turn over"; main, additional and informational inscriptions in accordance with GOST Packing Preservation of devices is carried out in accordance with GOST for product group III-3 with the option of temporary anti-corrosion protection VZ The devices are packed in consumer packaging - a cardboard box of type III-I GOST, a set of spare parts and operational documentation are also placed there on the device, packed in a bag made of polyethylene film GOST. The edges of the bag are sealed. Group spare parts are placed in plastic bags. The edges of the packages are welded Boxes with packed devices, a list of spare parts, group spare parts (if any) are placed in a shipping container - boxes of type II-I GOST, lined with GOST bituminous paper Each box (or container) contains a packing list containing the following information: 1 ) name and designation of devices and their number; 2) designation and number of group spare parts (if any); 3) month and year of packaging; 4) signature or stamp of the person responsible for packaging. It is allowed to pack devices in containers in accordance with GOST. Net weight - no more than 40 kg Gross weight - no more than 50 kg. 2 Intended use 2.1 Preparing the device for use Safety measures when preparing the device When using the device, observe the current "Rules for the technical operation of consumer electrical installations" and "Safety regulations for the operation of electrical installations of consumers". The sources of danger in the device are: - contacts ХТ1: 1 and ХТ1: 3 for connecting the AC mains. Mounting, installation, maintenance should be carried out with the mains voltage disconnected from the device. Do not use fuses that do not match the rated value. Installation and maintenance of the device must be carried out by persons with a safety qualification group of at least the third. Installation procedure The device is installed on walls or other structures of the protected premises in places protected from atmospheric precipitation, mechanical damage and access by unauthorized persons. Light annunciators must be placed in places clearly visible by the facility's owner after leaving the premises. 15

16 Installation of the device, light and sound annunciators is carried out in accordance with the RD "Rules for the production and acceptance of works. Installation of security, fire and security and fire alarms". Install the device in the following sequence: - determine the installation location of the device; - mark the fastening, mount the fastening elements; - install the device on the fastening elements. Install the loop and connecting lines in accordance with the wiring diagram given in Appendix B. Connect the connecting lines to the terminals of the device in the following sequence: - connect the wires of the external DC light annunciator to contacts 11 and 12 ХТ2 observing the polarity; - connect the wires of the external DC sounder to contacts 1 and 2 of XT2, observing the polarity; - connect the AL wires to contacts 7 and 8 of XT2; - connect the power supply circuits of the detectors to contacts 3 and 4 of XT2 observing the polarity; - connect the control panel lines to pins 5 and 6 of XT2; - connect external circuits "Fault" to contacts 13 and 4 XT2; - connect the lines from the backup DC power source to contacts 9 and 10 of XT2, taking into account the polarity; - connect the AC mains wires to contacts 1 and 3 of XT1; - the mains source of alternating current and the backup source of direct current must be connected to the device through switches, which are used to turn off the device. The S2 backup power supply switch must be installed in the circuit: positive terminal of the power supply - terminal XT2: 10. The S1 switch must be installed in the phase conductor of the network. When switching off the device, both power sources must be disconnected. Failure to turn off the backup DC power supply will discharge it. When the device is turned off for a long time, the built-in battery must be disconnected from the device. 2.2 Preparation for work Check the correctness of the installation and carry out a functional check of the device when powered from the AC mains in one of the operating modes: burglar alarm (jumpers "1" and "2" are installed) or fire alarm (jumpers "1" and "2" removed) in the following sequence. Check in the security alarm mode. Bring the AL to the standby state by closing doors, windows, transoms, etc. Check the operation of the device during the initial start-up period. Apply mains voltage to the device. Within 1 min after turning on the power supply, simulate the violation and restoration of the loop. If the AL is in good working order, the external constant current light annunciator and the built-in indicator should light up with an intermittent light 0.25 s on, 1.5 s off, if the AL is violated - with an intermittent light with a frequency of 1 Hz. The external DC sounder must be turned off. Check the amount of delay from the moment the loop is violated to the activation of the sounder. The delay value must be at least 30 s, if the device has removable 16

17 jumpers "1" and "2" are set and the delay is zero if jumper "1" is removed and jumper "2" is installed. Check the operation of the device in standby mode and in alarm mode. Violate the loop - open the front door and leave it open. Apply mains voltage to the device. The portable constant current light annunciator and the built-in indicator light up with an intermittent light with a frequency of 1 Hz. The external DC sounder must be turned off. Close the front door, while the illumination mode of the external light annunciator and the built-in indicator should become intermittent - 0.25 s on, 1.5 s off. Open the front door after 1.5 minutes. The portable light annunciator and the built-in indicator switch to a blinking alarm mode of illumination and after a delay of 30 s, the external constant current sounder is switched on for 2 minutes. Close the front door. The nature of the work of the sirens should not change. Check the device's ability to record the operation of each detector included in the AL. Check the device's ability to work with the centralized monitoring panel in the following sequence: 1) switch the device to standby mode and inform the operator at the monitoring station to arm the object; 2) put the device into the alarm mode of operation. The monitoring station operator must determine the violation of the alarm loop. Check the operability of the device according to p when powered from a backup power source or built-in rechargeable battery. Check in fire alarm mode. Remove jumpers "1" and "2". Bring the AL to the standby state, check the serviceability of the fire detectors included in the AL. Check the operation of the device in the "Fault" mode and in the "Fire" mode. After 15 seconds after turning on the device (arming in fire mode), simulate a short circuit and an open circuit of the alarm loop, triggering of fire detectors, restoring the loop to a standby state. Violate the loop (open or short circuit). The portable light annunciator and the built-in indicator of the device should light up in the following mode: 0.5 s - on, 3.5 s off. A remote audible constant current siren should operate in the following mode: 0.5 s - on, 3.5 s off. When the AL is restored to the standby state, the light annunciators and the indicator of the device must turn on in continuous mode, the sounder must turn off, the device switches back to the standby mode. Simulate a fire detector triggering. The external light annunciator and the built-in indicator of the device should shine with an intermittent light with a frequency of 1 Hz. A remote audible constant current siren should operate in the following mode: 0.5 s - on, 0.5 s off, and turn off after 4 minutes. Turn off the power to the device. Check the device's ability to record the operation of each fire detector included in the AL. Check the device's ability to work with the centralized monitoring station in the following sequence: 17

18 - switch the device to standby mode and inform the operator at the monitoring station to take the object under control; - switch the device to the "Fault" mode and back to the standby mode. The monitoring station operator must determine the open or short circuit of the fire alarm loop at the facility, and then the device switches to standby mode; - put the device into the "Fire" mode. The monitoring station operator must determine the triggering of a fire detector at the facility. Check the operability of the device according to p when powered from a backup power source and from the built-in rechargeable battery. 2.3 Using the device Arming the object in the following sequence. When operating in the burglar alarm mode (jumpers "1" and "2" are installed). For other states of jumpers "1" and "2", see table 4. 1) connect in series the power supplies of the device. Using the magnetic key supplied with the device, switch the device to the "Disarmed" mode; 2) close all windows, vents, doors, etc., on which electrical contact detectors are installed, open the exit door. Using the magnetic key supplied with the device, switch the device to standby mode; 3) in this case, the external light annunciator and the built-in indicator should blink, the external constant current sounder should not work; 4) inform the monitoring station attendant on the phone the conditional number of the object being handed over under protection, put the telephone receiver on the device; 5) leave the protected area and close the front door, while the blinking external dc light sounder should switch to intermittent mode 0.25 s on, 1.5 s off, which indicates the restoration of the alarm loop and switching the device to the transient mode ... When operating in the fire alarm mode (jumpers "1" and "2" are removed). 1) turn on the power supply of the device and after 15 s determine the normal state of the alarm loop and fire detectors using the light annunciators and the indicator of the device; 2) inform the monitoring station duty officer by phone the conditional number of the object to be handed over for fire protection, put the telephone receiver on the device; 3) leave the protected area, close the front door, remote sirens should shine with an even light. Disarm the object when opening the premises in the following order. When operating in the burglar alarm mode (jumpers "1" and "2" are installed): 1) open the front door, while the remote light network siren and the constant current siren should switch to the blinking mode of operation; 2) go to the device, using the magnetic key supplied with the device, switch the device to the "Disarmed" mode or turn off the power supply of the device; 3) call the monitoring station by the subscriber phone and inform the operator about the disarming of the object. It should be borne in mind that if the time from the moment the door is opened until the power supply to the device is turned off or the device is disarmed exceeds 30 s, the sounder will turn on. eighteen

19 When operating in the fire alarm mode (jumpers "1" and "2" are removed), the object is monitored by the monitoring station around the clock, while the power supply to the device is not turned off and the monitoring station controls the fire alarm loop of the object around the clock through two outputs of the device: the "Fault" output and the output Monitoring stations, through which, respectively, information about an alarm loop failure or fire detectors activation is transmitted to the monitoring station. 3 Maintenance Maintenance of the device is carried out according to the scheduled preventive system, which includes annual maintenance. Annual maintenance work is performed by an employee of the service organization and includes: a) checking the external condition of the device; b) functional check in accordance with section 3.1 of this manual; c) checking the reliability of fixing the device, the condition of external installation wires, contact connections. Checking the operability of the device This methodology is intended for engineers and technical workers and electricians of the fire alarm system servicing the technical means of security and fire alarms (TS OPS), checking the technical condition (incoming control), and includes checking the operability of the device in order to identify defects and assess them technical condition. Non-compliance of devices with the requirements specified in this methodology is the basis for filing claims with the manufacturer and calling his representative to continue checking and resolving the issue of eliminating defects. Checking the technical condition of devices is organized by laboratories and repair shops of security units and is carried out by service personnel who have studied the principle of operation of the device and this method and who have qualifications of at least 3 categories of OPS electricians. The check is carried out under normal climatic conditions in accordance with GOST: 1) ambient temperature - () О С; 2) relative air humidity - (45-80)%; 2) atmospheric pressure mm Hg. (84-106.7) kPa. The check is carried out using a general device check stand, the electrical circuit diagram of which is shown in Appendix D. The total time for checking the technical condition of one device is no more than 40 minutes. Notes: 1 Connect and disconnect the wires during the tests with the power off of the device and the stand. 2 All checks should be carried out taking into account the technical readiness time of the device, no more than 3 s. Check the device in the following sequence: Check the condition of the packaging and unpack the device. Check the delivery set in accordance with the operation manual of the ADSDR RE, the availability and composition of spare parts. Make sure that there is no mechanical damage to the device case. By shaking the device, make sure that there are no foreign objects inside it. 19

20 Check the fastening of the terminal block. Check the presence, compliance of the rating and serviceability of the device fuses. Check the compliance of the device number and date of issue with those specified in the manual. Control of the main technical characteristics of the device is carried out using a general test stand (Appendix D). Set the S1 S7 switches on the stand to the off position. Connect the stand to the AC mains. Turn on the mains switch of the stand and use the A5 variator to set the supply voltage of the device (220 ± 5) V, monitoring it with the PV3 voltmeter. Turn off the POWER switch. Switch on the constant current source A3 and set its output voltage (12 ± 0.5) V, monitoring it with the PV2 voltmeter. Install jumpers "1" and "2". Turn on the NETWORK switch of the stand and at the same time turn on the stopwatch. The built-in indicator of the device and the stand INDICATOR should shine with an intermittent light 0.25 s on and off for 1.5 s if the AL is not violated and shine with an intermittent light with a frequency of 1 Hz if it is violated. The indicator of the monitoring station stand should display the current state of the loop. It lights up if the loop is not violated and does not light up if it is violated. The SIREN indicator should not light up. Record the time until the device indicators and the stand INDICATOR turn on in the continuous glow mode, which should be 60 s. Briefly press the CIRCUIT S2 switch of the stand. Measure, using a stopwatch, the delay time for the SIREN indicator, which should be 30 s, and then the time for the SIREN indicator to turn on, which should be 2 minutes. The monitoring station indicator should turn off. Using a stopwatch, measure the blinking frequency of the built-in indicator of the device and the INDICATOR of the stand; the frequency is determined as a quotient of dividing the number of flashes by the selected time (10 s). If the device is working properly, the blinking frequency should be 1 Hz. Bring the magnetic key from the device kit into the zone of influence on the magnetically controlled contact. While holding the magnetic key in the zone, the AL indicator of the device and the stand INDICATOR indicator should glow with an intermittent light with a frequency of 6 Hz. The built-in indicator of the device and the indicators INDICATOR, SIREN and CMS of the stand must be turned off. Re-bring the magnetic key to the affected area and remove it. The device should start to work according to p. Turn off the POWER switch of the stand. Remove jumpers "1" and "2". In this case, the device is configured to work in fire mode. Turn on the NETWORK switch of the stand and at the same time turn on the stopwatch. The built-in indicator of the device, stand indicators INDICATOR, SIREN and CMS should not light up. Record the time until the indicator of the device and the indicator of the INDICATOR stand turns on, which should be no more than 15 s. Press the switch "Open" S2 or "Short circuit" S6 of the stand. The FAULT indicator should turn off. Using a stopwatch, measure the time of the on and off state of the device indicator, the indicator of the INDICATOR stand, which should be 0.5 s and 3.5 s, respectively. Press the "Break" switch S2 or "Short circuit" S6 of the fire alarm loop simulator. The device should go into standby mode. twenty

21 Press and release the S5 switch of the stand. The monitoring station indicator should turn on. Using a stopwatch, measure the time when the SIREN indicator is on in the mode: 0.5 s on, 0.5 s off, which should be 4 minutes. Turn off the CHAIN ​​switch of the stand. Install jumpers "1" and "2". Press the OPEN switch S2 and turn on the POWER switch of the stand. Using voltmeters PV4 and PV2, measure the voltage in the loop and the power supply circuit of the detectors, which, respectively, should be no more than (12 + 1.2-1.8) V. Press the break switch S2. Using a PV1 voltmeter, measure the voltage in the AL and the power supply circuit of the detectors, which, respectively, should be (10-13) V and (12.0 + 1.2-1.8) V. Turn off the POWER switch of the stand. Disconnect S1 (output 12 V), indicators INDICATOR, SIREN from the stand and turn on the POWER switch. Measure the current consumed by the device with a PA3 milliammeter, which should be no more than 30 mA. Turn on the stand RESERVE switch and turn off the mains stand switch. The device must remain in standby mode - the indicator of the monitoring station stand must light up. Measure the current consumed by the device with a PA1 milliammeter, which should be no more than 90 mA. Using voltmeters PV1 and PV4, measure the voltage in the AL and the power supply circuit of the detectors, which, respectively, should be (10-13) V and (12.0 + 1.2-1.8) V. Make an entry in the repair log and input control of the means of the FSA on the results of the check. 4 Current repair The list of the most common or possible malfunctions and the ways of their elimination are given in table 4.1. The list of instrumentation required for repair in a workshop is given in Table 4.2, the approximate consumption of components and materials required for maintenance and repair of the device is in Table 4.3. Table 4.1 Name of malfunction, Probable cause Method of elimination External manifestation and additional symptoms 1 When the mains supply is turned on No power supply Check for the presence of a power supply built-in voltage in the mains voltage in the mains LED indicator does not light up Fuses defective Replace the mains power supply fuses in the device. LED Defective Replace 2 When the power supply is turned on, the fuse breaks down. Thermal fuse. Short circuit in the secondary or primary circuits of the transformer, breakdown of the bridge rectifier, breakdown of the capacitor. Thermal fuse. Check the serviceability of the transformer, bridge rectifier, capacitor. Replace defective elements 21


GIPPO-1M security and fire control device The GIPPO-1M fire control and fire control device is designed to monitor the state of the alarm loop (AL), both in stand-alone mode with

1 General information FIRE ALARM CONTROL DEVICE PPKOP 051-1-3 UOTS-1-1A USER MANUAL Thank you for choosing the UOTS-1-1A device manufactured by NPO Siberian ARSENAL. You purchased

POWER SUPPLY BBP-200 ТУ 4372 002 63438766 14 CERTIFICATE OF CONFORMITY ТС RU С-RU.АВ24.B.04521 Series RU 0477342 PASSPORT INTRODUCTION

Control panel Fire and security PPKOP 051-1-3 УОТС-1-1А OPERATION MANUAL CONTENTS GENERAL INFORMATION ... 2 INDICATION OF SAFETY MEASURES ... 2 TECHNICAL DATA ... 3 INSTALLATION AND PREPARATION PROCEDURE

RESERVED POWER SUPPLY OF RIP-24 FSA EQUIPMENT version 01 АЦДР.436534.002-01 ME61 label 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for RIP-24 FSA equipment

POWER SUPPLY BBP-24 TU 4372 002 63438766 14 CERTIFICATE OF CONFORMITY ТС RU С-RU.AL16.B.02558 Series RU 0228076 PASSPORT INTRODUCTION

POWER SUPPLIES BBP-0, BBP-0, BBP-0, BBP-00 TU 00 CERTIFICATE OF CONFORMITY CU RU С-RU.AL.B.0 Series RU 00 PASSPORT INTRODUCTION

POWER SUPPLIES BBP-0, BBP-0, BBP-0, BBP-00 TU 00 CERTIFICATE OF CONFORMITY ТС RU С-RU.AB.B.0 Series RU 0 PASSPORT INTRODUCTION

TERMINAL DEVICE UO-2 OF THE "FOBOS-3" NOTIFICATION TRANSMISSION SYSTEM Operation manual АЦДР.425632.002 OM 2002 Contents Page. Introduction 1 1 Description and operation of the product 1 1.1 Purpose of the product

POWER SUPPLY BBP-20M TU 4372 002 63438766 14 CERTIFICATE OF CONFORMITY ТС RU С-RU.AЛ16.B.02558 Series RU 0228076 PASSPORT INTRODUCTION

Fire alarm control panels PPKOP 0104059-1-4 "Signal-VKA", series 01 PPKOP 0104059-1-4 / 01 "Signal-VKA", isp.01 series 01 Operating manual АЦДР.425513.011 OM 2001 С о f g

PASSPORT for uninterruptible power supply BBP-100 POWER SUPPLY BBP-100 TU 4372 006 63438766 11 CERTIFICATE OF CONFORMITY ROSS RU.HP28.B07734 PASSPORT 1. INTRODUCTION This passport is intended for study

ALARM-CONTROL DEVICE SECURITY-FIRE QUARTZ (UOTS-1-1A) option 3 OPERATION MANUAL BB02 UP001 Dear customer! Thank you for choosing our products. In the creation of modern high-quality

PASSPORT for an uninterruptible power supply unit BBP-20, BBP-30 POWER SUPPLIES BBP-20, BBP-30 TU 4372 001 63438766 12 CERTIFICATE OF CONFORMITY ROSS RU.HP28.V07734 CERTIFICATE OF CONFORMITY ROSS.V.

TERMINAL DEVICE UO-2 OF THE "FOBOS-3" NOTIFICATION TRANSMISSION SYSTEM Operation manual АЦДР.425632.002 OM 2007 CONTENTS Page. Introduction ... 4 1 Description and operation of the product ... 4 1.1 Purpose of the product ... 4

Operating instructions Redundant without battery power supply RIP-12 isp.03 for battery 7 Ah 242872 Prices for goods on the website: http://www.vseinstrumenti.ru/electrika_i_svet/sistemy_bezopasnosti/sistemy_pozharno-

RESERVED POWER SUPPLY OF OPS "RIP-12" EQUIPMENT isp. 05 Label АЦДР.436534.001-09 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for the RIP-12 fire alarm system

ALARM-CONTROL DEVICE SECURITY-FIRE QUARTZ option 3 OPERATING MANUAL SAPO.425513.006 RE Certificate of conformity С- RU.ПБ01.В.00877 Dear Customer! Thank you for choosing our

POWER SUPPLIES BBP-0, BBP-5, BBP-20, BBP-24 PASSPORT 437 00 080570 03 PS. INTRODUCTION This passport is intended for study by the service personnel of the rules of operation of power supplies ББП-0, ББП-5,

ISO 9001 REDUNDANCED POWER SUPPLY OF EQUIPMENT OPS "RIP-12 isp. 06 "Label АЦДР.436534.001-12 ЭТ ПБ01 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply of the equipment

ALARM - CONTROL DEVICES SECURITY - FIRE Control Panel 0104059-2-1 "Signal VK2", Control Panel 0104059-2-1 / 01 "Signal-VK2" isp. 01 АЦДР.425513.013 OM Operation manual 2002 CONTENTS Introduction 3 1 Description

RESERVED POWER SUPPLY RIP-12 version 05 (RIP-12-8 / 17M1) Label АЦДР.436534.001-09 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply RIP-12 version 05 (RIP-12-8 / 17M1)

POWER SUPPLY MIP-12 ver.02 (MIP-12-1 / P3) Label АЦДР.436434.002 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Power supply MIP-12 ver.02 (MIP-12-1 / P3) ( hereinafter MIP) is intended

Inv. double. Subp. and date Ref. First. apply. Take it. inv. АЦДР.425513.013 CONTENTS Introduction 3 1 Description and operation of the device 3 1.1 Purpose of the device 3 1.2. Characteristics 5 1.3. Completeness 22 1.4 Device

1 RESERVE-12/5 SOURCE OF SECONDARY POWER SUPPLY RESERVED IMPULSE RESERVE-12/5 PASSPORT TU 4372-001-79131875-08 2 RESERVE-12/5 1. PURPOSE 1.1. Redundant secondary power supply

REDUNDANT POWER SUPPLY OF EQUIPMENT OPS RIP-24 isp.01 (RIP-24-3 / 7M4) Label АЦДР.436534.002-01 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply of equipment

ELECTRA Group of Companies www.electra-n.ru RESERVED POWER SUPPLY SOURCE IRP 12-6 Operation manual Free OP066 certification ACCEPTANCE CERTIFICATE Redundant source

ISO 9001 RESERVED POWER SUPPLY OF EQUIPMENT OPS "RIP-12" isp. 02P Label АЦДР.436534.001-13 ET PB01 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for the equipment

ELECTRA Group of Companies www.electra-n.ru RESERVED POWER SUPPLY SOURCE IRP 12-6 (24-3) Operation manual Voluntary OP066 certificate ACCEPTANCE CERTIFICATE Reserved

1 RESERVE-12/2 SOURCE OF SECONDARY POWER SUPPLY RESERVED IMPULSE RESERVE-12/2 PASSPORT TU 4372-001-79131875-08 2 RESERVE-12/2 1. PURPOSE 1.1. Redundant secondary power supply

NPO MicroKomServis LLC RESERVED POWER SUPPLY SOURCE Outdoor version RESERVE-12 / 5U18 (IP56) 12V 5A 18Ah PASSPORT Operation manual TU 4372-001-79131875-08 WWW.R-BP.RU TVER, 2015

CONTROL DEVICE FOR VOICE SIGNALS "SONATA-K-20" PASSPORT TU 4372-0-5643358-2005 POCC RU.ПБ6В.0027. General information Name: CONTROL DEVICE FOR VOICE SIGNALS "SONATA-K-20" Date of manufacture:

MP06 UNINTERRUPTABLE POWER SUPPLY UNITS BBP-10, BBP-20, BBP-24 OPERATION MANUAL 4371 001 40267658 04 OM

CONTROL DEVICE FOR VOICE SIGNALS "SONATA-KL-BR" PASSPORT TU 4372-0-5643358-2005 POCC RU.PB.6.V.0027.General information Name: CONTROL DEVICE FOR VOICE SIGNALS "SONATA-KL-BR" Date of manufacture

26.30.50.129 SOURCE OF UNINTERRUPTED POWER SUPPLY BRP-12 version 1 Passport ATPN.436234.001-15 PS Label location Manufactured and adopted in accordance with the mandatory requirements of state

NPF SIGMA-IS LB-06 Linear addressable unit (ver 4.52) Operating manual SAKI.425641.004RE SAKI.425641.004 RE 1. PURPOSE ... 3 2. COMPLETE SET ... 3 3. TECHNICAL CHARACTERISTICS ... 4 4. DEVICE

OOO SIGMA-IS LB-06 Linear addressable block (ver 4.52) Operating manual SAKI.425641.004RE LB-06. Operation manual 1. PURPOSE ... 3 2. COMPLETE SET ... 3 3. TECHNICAL SPECIFICATIONS ...

SWITCHING DEVICE UK-VK UK-VK ver.10 UK-VK ver.11 UK-VK ver.1 UK-VK ver.13 UK-VK ver.14 UK-VK ver.15 Label АЦДР.4641.00 ET 1 BASIC TECHNICAL DATA 1.1 General 1.1.1 This label

Uninterruptible Power Supply "AKAT" Passport Russia Tver - 1 - UNINTERRUPTED POWER SOURCES AKAT PASSPORT 1. INTRODUCTION This passport is intended for study by the operating personnel of the operating rules

ALARM-CONTROL DEVICE SECURITY-FIRE QUARTZ OPTION 1 OPERATION MANUAL UP001 General information 1 18 Thank you for choosing the "QUARTZ" device manufactured by NPO "Siberian ARSENAL". This product

Operation manual Pulsed secondary power supply source OPTIMUS-1230-OD Secondary power supply source OPTIMUS 1230-OD ARGP.435520.003TU is designed to provide power supply

CONTROL DEVICE FOR VOICE SIGNALS "SONATA-K-L" PASSPORT CODE OKPO 43 7242 TU 4372-011-56433581-2005 С-RU.AB03.V.00025 1. General information Name: CONTROL DEVICE FOR VOICE SIGNALS "SONATA-K-L"

SECONDARY POWER SUPPLY RESERVED BBP-30 V.4 TS Technical data sheet Redundant secondary power supply with filtering from mutual influence of consumers on each channel

Electronic Technologies LLC Uninterruptible power supplies BBP-20, BBP-25, BBP-30, BBP-35, BBP-40, BBP-50, BBP-55, BBP-24-3. Passport UNINTERRUPTED POWER SUPPLIES PASSPORT 1 INTRODUCTION This Passport

Ministry of Internal Affairs of the Russian Federation Federal State Institution "Scientific Research Center" Okhrana "Novosibirsk Branch (NF Scientific Research Center" Okhrana ") 43 729 AC voltage stabilizer

RESERVED POWER SUPPLY RIP-12 isp.01 (RIP-12-3 / 17M1) Label АЦДР.436534.001-01 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply RIP-12 isp.01 (RIP-12-3 / 17M1)

Edition 01 EN ISO 9001 A DETECTORS FIRE THERMAL MAXIMUM R T RTL-A1 RTL-A2 RTL-A3 RTL-B О PASSPORT MCI 425212.006-06 PS N Chernivtsi, Ukraine 2012 INTRODUCTION This passport is intended for

VOICE ALARM UNIT ARIYA-BRO-R TU 4372-021-49518441-10, rev. 4 1. Purpose The ARIA-BRO-R voice announcement unit (hereinafter referred to as the "product") is designed to work as part of the ARIA voice announcement system

ISO "Orion" Voice announcement unit "Rupor" Installation instructions АЦДР.425541.001 IM These installation instructions contain instructions for performing basic installation and preparation steps

ALARM CONTROL DEVICE SECURITY - FIRE Control Panel 0104059-6-1 "Signal VK-6" АЦДР.425513.006 OM Operation manual CONTENTS Introduction 1 1 Description and operation of the product 1 1.1 Purpose of the product 1

VOICE ALARM UNIT AMBER BRO 1. Purpose Voice announcement unit AMBER BRO (hereinafter "product") is designed to work as part of a voice announcement system as a formation device

Control panel Fire and security QUARTZ option 1 OPERATION MANUAL CONTENTS GENERAL DATA ... 2 TECHNICAL DATA ... 3 DEVICE DESIGN ... 4 INSTALLATION PROCEDURE ... 5 PREPARATION FOR WORK ... 5

ISO "Orion" Voice announcement unit Rupor isp. 01 Installation manual АЦДР.425541.001-01 ИМ These installation instructions contain instructions for performing basic installation and

1 GENERAL INFORMATION Thank you for choosing a device of the "Granite" family, manufactured by NPO "Siberian Arsenal". This product will provide reliable protection of your facility from intrusion and fire. Receiving and control device

Transcript

1 Control and monitoring device security and fire PPKOP / 02 "Signal-VK" isp. 02 ADSDR RE Operation manual CONTENTS Introduction 1 1 Description and operation of the product Purpose of the product Characteristics Composition of the product Structure and operation of the product 7 2 Intended use Preparing the product for use Using the product 11 3 Checking the technical condition of the device 11 4 Maintenance 14 5 Maintenance 15 Appendix А Overall and mounting dimensions of the device 16 Appendix B Electrical functional diagram of the device 17 Appendix C Wiring diagram of the device 18 Appendix D Scheme of general verification of the device 19 Appendix E Device for checking the time parameters of AL 20 This operation manual is intended to study the principle of operation and operation of the device control fire and security control PPKOP / 02 "Signal-VK" isp Description and operation of the product 1.1 Purpose of the product Control and fire alarm device PPKOP / 02 "Signal-VK" isp. 02 (hereinafter - the device) is intended for centralized and autonomous protection of shops, cash registers, banks, pharmacies, institutions and other objects from unauthorized intrusions and fires by monitoring the state of the alarm loop (AL) with security, fire or security and fire detectors included in it and issuing notifications to the centralized monitoring station (CMS) about violation of the loop, as well as the control of external sound and light annunciators at the facility. The device is designed for joint operation with centralized observation consoles such as "Siren-2M", "Neva-10", "Neva-10M", "Center-M", "Center-KM", "Progress-TS", "Phobos" and tp The AL of the device can include: - magnetic contact detectors IO102-2, "SMK-1", "SMK-2", "SMK-3"; - sensors such as "Foil", "Wire"; - shock-contact detectors such as "DIMK", "Window-4", "Window-5", "Window-6"; 1

2 - detectors of optical-electronic, ultrasonic and radio wave types 9981, "Foton-5", "Foton-6", "Foton-8", "Foton-SK", "Vector-2", "Vector-3", " Echo-2 "," Wave-5 "and the like; - output circuits of control and monitoring devices; - heat fire detectors "IP-104-1", "IP103-4 / 1" ("МАК-1"); - magnetic contact fire detectors "IP-105-2 / 1"; - fire detectors smoke type "IP-212-5" ("DIP-3"), "IP" ("DIP-6"), "IP U" ("DIP-U"), "IP" ("DIP- 34 ")," IP-212-3SU "(" DIP-3SU ") SHS. At the same time, it is possible to set a delay for turning on the sounder when the alarm loop is violated. protected object of detectors such as "Photon", "Echo", "Wave", "Peak", "Vector" and the like. the built-in indicator and in the switched off mode of sirens and the built-in indicator using a remote control over the radio channel at a distance of up to 30 m fire hazardous premises By type of technology The instrument is a periodic maintenance product. The average total operational duration of maintenance is not more than 0.15 hours per month. The device is designed for operation under the following conditions: 1) operating ambient temperature range - from 243 to 323 K (from minus 30 to +50 О С); 2) relative humidity at an ambient temperature of 298 K (+25 0 C) - up to 98%; 3) vibration loads in the range from 1 to 35 Hz with a maximum acceleration of 0.5 g (4.9 m / s 2). 1.2 Characteristics The device is powered from an alternating current with a frequency of (50 ± 1) Hz, () V. 2

3 1.2.2 Supply voltage from a redundant DC source - (12.0 ± 1.8) V The power consumed by the device from the AC mains without a network siren in standby mode and in the "Alarm" mode should be no more than 12 V A The current consumed by the device from a backup source, taking into account the power supply of active detectors according to p in standby mode and alarm mode - no more than 140 mA "Alarm" at the monitoring station "Alarm" Loop at the monitoring station "Norma" in the alarm loop (on the built-in indicator) "Alarm" in the loop (on the built-in indicator) "Normal" for the remote mains and direct current light annunciators "Alarm" for the remote mains and direct current light annunciators "Alarm" on the remote mains and direct current sound annunciators The device provides switching of the remote light and sound annunciators in accordance with Table 2. Table 2 Types of annunciators. power External light direct current 12 V, 50 ma External acoustic direct current 12 V, 0.3 A External light mains up to 60 W Remote sound mains up to 60 W from 2 to 11 rooms The device remains in standby mode if the alarm loop is violated for a time of 50 ms or less. The instrument switches to the "Alarm" mode when the alarm loop resistance is less than 2 kΩ or more than 11 kΩ for a period of 70 ms or more, or by pressing button "2" of the remote control. in seven operating modes: - power-on mode; - transition to standby mode; - standby mode; - "Alarm" mode; - the mode of the switched off annunciators and indicators; - programming mode; - erasing keyfob codes from memory. Power on mode The device after switching on the supply voltage for 2 minutes does not remember the violation of the loop and provides the following operating procedure: 1) in the normal state of the loop: 3

4 - built-in indicator (red color) and remote light annunciators are lit with continuous light; - remote sound annunciators are turned off; - the output contacts of the monitoring station relay are closed; 2) in case of a loop violation according to clause 1.2.9: - remote light annunciators and a built-in indicator (red) glow with an intermittent light with a frequency of 1 Hz; - the output contacts of the monitoring station relay are open for the duration of the loop violation according to clause 1.2.9; - remote sound annunciators are turned off; 3) when the alarm loop is restored to its normal state according to clause 1.2.8: - the built-in indicator of the device (red) and the remote light annunciators glow with continuous light; - remote sound annunciators are turned off; - monitoring station relay contacts are closed; 4) at the end of 2 minutes, the device switches to standby mode, the indicator and light annunciators turn off for 1 s, and sounders turn on for 0.05 s Switch to standby mode When the supply voltage is on, when you press button "1" of the remote control included in the kit of the device, the sounders are switched on for 0.05 s and it must not memorize the violation of the loop for 2 minutes and must ensure the following operating procedure: 1) in the normal state of the loop according to clause 1.2.8: - built-in indicator (red) and remote light annunciators glow with continuous light; - remote sound annunciators are turned off; - the output contacts of the monitoring station relay are closed; 2) in case of a loop violation according to clause 1.2.9: - remote light annunciators and a built-in indicator (red) glow with an intermittent light with a frequency of 1 Hz; - the output contacts of the monitoring station relay are open for the duration of the loop violation according to clause 1.2.9; - remote sound annunciators are turned off; 3) when the alarm loop is restored to its normal state according to clause 1.2.8: - the built-in indicator of the device (red) and the remote light annunciators glow with continuous light; - remote sound annunciators are turned off; - monitoring station relay contacts are closed; 4) at the end of 2 minutes, the device switches to the standby mode of operation, the indicator and light annunciators turn off for 1 s and the sound sounders turn on for 0.05 s.

5 - continuous illumination of the built-in indicator of the device (red color) and remote light annunciators; - off state of external sound annunciators; - closed state of the monitoring station output contacts "Alarm" mode The control panel switches from standby mode to "Alarm" mode when the alarm loop is violated according to p or by pressing the button "2" of the key fob, while it provides: 1) intermittent switching on of the built-in indicator (red) and remote light annunciators with a switching frequency of 1 Hz; 2) switching on of the remote sounder sounders immediately for a time of 2 minutes with the "XT3" jumper installed or after 30 seconds with the "XT3" jumper removed, after a loop violation or pressing the button "2" of the remote control; 3) permanent open state of the monitoring station relay contacts. Restoring the alarm loop to its normal state should not lead to a change in the "Alarm" mode until the control panel is powered off or shortly pressed button "1" of the remote control. power supply or switching to standby mode after short pressing of the button "1" of the remote control. At the same time, it provides: 1) off state of the built-in indicator of the device and external light annunciators; 2) off state of external sound annunciators; 3) the closed state of the output contacts of the monitoring station relay in the normal state of the alarm loop according to p and not pressed button "2" of the key fob and their open state, for at least 2 s, in case of violation of the loop according to p or while pressing the button "2" of the key fob. The transition to the standby mode according to p should be carried out by briefly pressing the button "1" of the remote control. Programming mode Switch the device to the switched off sirens mode by pressing the button "1" of the remote control. When the built-in PROG button is pressed, the built-in indicator should glow green for 0.5 s and the keyfob programming mode starts. Without releasing the PROG button, press buttons 1 or 2 on the master remote control from the accessory kit. The indicator blinks green twice. After that, pressing buttons 1 or 2 on the programmable key fob enters its code into the device memory, while the indicator glows green for 0.5 s. If this key fob code is already stored in memory, the indicator blinks green three times. If 40 key fobs have already been programmed (not counting the master key fob), then when you try to program 41 key fobs, the indicator glows green for 1.5 s. When the PROG button is released, the indicator glows green for 1 s and returns to the mode of switched off sirens and indicators Mode of erasing keyfob codes from memory 5

6 To enter this mode, turn on the power to the device while pressing the PROG button. After four initial flashes, the indicator glows green for 0.5 s. Without releasing the PROG button, press the buttons 1, 1, 2, 2 on the master key fob, while the indicator glows green for 0.5 s after each press. If the code is entered correctly, the indicator glows green for 1 s and the memory is cleared; otherwise, the indicator is off. If the code is entered by mistake, it is necessary to repeat the switch-on with the pressed PROG button. In this mode, the master key fob code is not erased. After releasing the PROG button, the transition to the standby mode begins. The device provides power supply to active detectors with the following parameters: - supply voltage (12 + 1.8-1.2) V; - consumed current - no more than 40 ma. The value of the ripple voltage in the 12 V channel (peak value) - no more than 15 mV The device remains operational after a short circuit in the power supply circuit of active detectors. The maximum number of detectors connected to the AL is at least 20 pcs. The device provides power supply to the AL for fire detectors of the "DIP" type. The maximum number of connected detectors should be no more than: "DIP-3" - 3 pcs., "DIP-6" - 8 pcs., "DIP-U" 20 pcs., "DIP-34" 20 pcs., "DIP- 3SU "20 pcs. The device switches from the standby mode of operation to the" Alarm "mode when detectors (" Window "," DIP "," Volna-5 "," Photon-8 ") are triggered. more than 20 ma flowing through a triggered detector powered by the AL The device provides at the AL input, in the standby mode of operation, a voltage from 21 to 24 V. In the alarm mode, the voltage at the AL input is not more than 27 V Maximum voltage switched by the contacts of the control panel relay, not less than 80 V, switching current not less than 50 ma The control panel relay contacts of the monitoring station control panel open when there is no supply voltage (and there is no backup source) Time of technical readiness of the device for operation no more than 3 s sinusoidal form with a frequency of 50 Hz effective th voltage value up to 1 V, as well as impulse inductions in the form of single voltage pulses with an amplitude of up to 300 V, duration up to 10 ms The device does not generate false signals when automatically switching to power from a backup source and vice versa, as well as when exposed to electromagnetic interference of the third degree of severity according to GOST R Industrial radio interference generated by the device during operation does not exceed the values ​​specified in GOST R Weight of the device - no more than 2 kg Overall dimensions of the device - no more than 157x151x71 mm. 6

7 Content of precious materials: - gold - 0.028 g, - silver - 0.054 g. 1.3 Product composition The composition of the device must correspond to that indicated in Table 3. Table 3 Designation Name, designation Quantity. АЦДР The device is receiving and control security and firefighter 1 PPKOP / 02 "Signal-VK" isp. 02 Set of spare parts: Resistor ОЖО ТУ С2-33Н-0.5-8.2 kΩ + 5% 1 АЦДР РЭ Fuse inserts ОЮ ТУ ВПТ6-10 (2 А) ВПТ6-5 (0.5 А) 2 2 Remote controls 2 Control and monitoring device security and fire PPKOP / 02 "Signal-VK" isp. 02 Operation manual ATsDR Group spare parts set for 12 devices 1 ATsDR ZI Spare parts list for the "Signal-VK" device isp Design and operation of the device The device is structurally made in the form of a plastic case, consisting of a base and a cover. The appearance of the device and its overall dimensions are given in Appendix A. A printed circuit board is installed inside the case on the base, on which all the main elements and assemblies of the device are mounted. On the reverse side of the base there are two shaped holes, with the help of which the device is fixed on the wall in the working position. The electrical connection diagram of the device is given in Appendix B. The device consists of the following functional units: - input unit and rectifier; - voltage stabilizers 12 V and 5 V; - voltage converter from 12 V to 24 V; - divider of the reference voltage; - single-chip microcontroller; - receiver module; - node for monitoring the state of the loop; - node of sound annunciators; - unit of light annunciators and signaling device; - signal relay assembly; - unit for monitoring the opening of the case; - keyfob programming unit; - node for delayed activation of sound annunciators. The input unit and rectifier contains fuse-links, a step-down mains transformer with a thermal fuse, a rectifier and a smoothing filter. The central processing, memorizing and control unit is made on a single-chip microcontroller, which provides: 7

8 1) input of an analog signal via three channels from the loop state control unit and from two points of the reference voltage divider that set the response thresholds, and their comparison; 2) input and processing of digital signals from the keyfob programming unit (S1), the case tamper control unit (S2), the unit for delaying the activation of sound annunciators (jumper XS1); 3) reception and processing of parcels from the remote control using the receiver module, registration of their individual numbers; 4) output of control signals for the built-in indicator of the device, control panel relay of the monitoring station, remote light and sound annunciators; 5) generating signals for the operation of a voltage converter from 12 V to 24 V. Setting a 30-second delay for turning on the sound annunciators is carried out by the XS1 jumper. The presence of the XS1 jumper in the XT3 male connector means that the sounder will be activated without delay; absence of XS1 jumper results in a 30 s delay in sounder activation. The receiver module contains an antenna and a receiver, from the output of which the signal goes directly to the microcontroller input. The unit is powered from a 5 V stabilizer. When the key fob button is pressed, the receiver module receives a code message and transmits it in a serial code to the microcontroller input. The AL state control unit supplies 24 V voltage through the limiting resistor to the alarm loop and supplies voltage from the loop through the matching circuit to the analog input of the microcontroller. The light annunciator assembly, the annunciator and indicator are controlled directly from the microcontroller outputs and includes an LED indicator with a controlled glow light, a key amplifier that controls a constant current light annunciator, and a relay through the contacts of which the light network annunciator is connected. The sounder assembly includes a key transistor that controls a constant current sounder, protective diodes and a relay controlled by the microcontroller output, through the contacts of which the sounder network siren is connected. The alarm relay assembly contains a diode-protected reed relay controlled by a microcontroller output. The case opening control unit contains a microswitch (S2), the signal from which goes to the microcontroller and in case of case opening the device goes into the "Alarm" state. 2 Intended use 2.1 Preparing the device for use Safety measures when preparing the device: a) When using the device, observe the current "Rules for the technical operation of consumer electrical installations" and "Safety regulations for the operation of electrical installations of consumers". b) The sources of danger in the device are: 1) contacts "~ 220 V" for connecting the AC mains; 2) contacts ХТ1: 1 - ХТ1: 4 for connecting external sound and light annunciators; 3) fuse holders on the input block (F1, F2); 4) contacts of the input winding of the power transformer (T1). eight

9 c) Mounting, installation, maintenance should be carried out with the mains voltage disconnected from the device. d) Electrical wires must be protected from possible insulation breakdown in places where metal edges are bent. e) Do not use fuses that do not match the rated value. f) Installation and maintenance of the device must be carried out by persons with a qualification group for safety not lower than the third. Installation procedure a) The device is installed on walls or other structures of the protected premises in places protected from atmospheric precipitation, mechanical damage and access by unauthorized persons. b) Light annunciators must be placed in places clearly visible by the facility's management after leaving the premises. c) Installation of the device, light and sound annunciators is carried out in accordance with the RD "Rules for the production and acceptance of works. Installations of security, fire and security and fire alarms". d) Install the device in the following sequence: 1) determine the place of installation of the device; 2) mark the fastening according to Appendix A, mount the fastening elements; 3) install the device on the fastening elements. e) Install the loop and connecting lines in accordance with the wiring diagram given in Appendix B. f) Connect the connecting lines to the device terminals in the following sequence: 1) connect the wires of the network light annunciator to contacts 3 and 4 XT1 and current to contacts 11, 12 XT2 (see Appendix B); 2) connect the wires of the network sounder to contacts 1 and 2 of XT1, and the DC sounder to contacts 1 and 2 of XT2, observing the polarity; 3) connect the AL wires to contacts 7 and 8 of XT2; 4) connect the power supply circuits of the detectors to contacts 3 and 4 of XT2, observing the polarity; 5) connect the control panel lines to pins 5 and 6 of XT2; 6) connect a backup DC power supply to pins 9 and 10 of XT2 taking into account the polarity; 7) connect the AC mains wires to pins 5 and 6 of XT1; 8) AC power supply and a backup DC power supply must be connected to the device through switches that are used to turn off the device. The S2 backup power supply switch must be installed in the circuit: positive terminal of the power supply - terminal XT2: 10. The negative terminal of the power supply must be connected to the XT2: 9 terminal. The S1 switch must be installed in the circuit: phase outlet of the network - terminal XT1: 6. When switching off the device, both power sources must be disconnected. Failure to turn off the backup DC power supply will discharge it Preparing for operation 9

10 Check the correctness of the installation and check the operability of the device when powered from the AC mains The device provides operability in seven modes of operation in accordance with clause of this document.To check the operability of the device, it is necessary to: 1) bring the alarm loop into standby state by closing doors, windows, transoms, etc. NS.; 2) check the operation of the device during the initial start-up period. Apply mains voltage to the device. Within 1 minute after turning on the power supply, simulate the violation and restoration of the loop, including by pressing and releasing the button "2" of the remote control. If the AL and the device are in good working order, the light annunciators and the built-in indicator should glow with a steady light, if the AL is violated - with an intermittent light. Sounders should be turned off. Switch the device to the switched off sirens and device indicator mode by short-term (not less than 1 s duration) pressing the button "1" of the remote control; 3) set the delay from the moment the loop is violated until the sounder is activated (remove the XS1 jumper from the XT3 pin connector); 4) check the operation of the device in the switched off sirens, standby and alarm modes. Violate the loop - open the front door and leave it open. Apply mains voltage to the device and briefly press the button "1" of the remote control. Light and sound annunciators and the built-in indicator of the device must be turned off. Briefly press button "2" of the remote control. The light annunciators and the indicator of the device should shine with an intermittent light. Sounders should not work. Close the front door, while the illumination mode of the light annunciator and the built-in indicator should become continuous. Open the front door after 2.5 minutes. The light annunciators and the built-in indicator should switch to a blinking alarm mode of illumination and after a delay of 30 s, the sounders will turn on for 2 minutes. Close the front door. The nature of the work of the sirens should not change. Briefly press button "1" of the remote control. Light and sound annunciators and the indicator of the device should turn off; 5) check the operation of the device in the keyfob programming mode. Switch the device to the switched off sirens mode by short-term pressing of the button "1" of the remote control. The external light annunciators and the built-in indicator of the device should turn off. If the light indication did not shine, then the key fob button should not be pressed (otherwise the device will go into standby mode, as evidenced by the inclusion of the light indication). Open the device case, press the S1 button installed on the device board. The built-in indicator of the device will light up in green continuous light. Remote light annunciators do not light up at the same time. Without releasing the S1 button, press any of the remote control buttons for a few seconds. Successful recording of the individual number of the key fob into the device memory (registration) will be confirmed by a short-term deactivation of the built-in indicator. Release the S1 button, close the cover of the device. Check the device's ability to perceive the commands of the registered key fob according to p by switching to various operating modes (short pressing of the "1" button switches the device to the off sirens mode and back to the standby mode; short pressing of the "2" button puts the device into alarm mode) Check the device's ability to record triggering of each detector included in the AL Check the device's ability to work with the centralized monitoring panel in the following sequence: 1) put the device into standby mode and inform the operator at the monitoring station to 10

11 the object was taken under protection; 2) put the device into the alarm mode of operation. The operator of the monitoring station must determine the violation of the loop. Check the operability of the device according to p when powered from a backup power source. Remove the mains and backup voltage from the control panel. 2.2 Use of the product Put the object under security in the following sequence: 1) close all windows, vents, doors, etc., on which electric contact detectors are installed, open the exit door; 2) briefly press the button "1" of the remote control no further than 30 m from the device. In this case, the light annunciators and the built-in indicator must be turned off, the sound annunciators must not work; 3) inform the monitoring station duty officer by phone the conditional number of the object being handed over under protection, put the telephone receiver on the device; 4) exit the protected area, close the front door and briefly press the button "1" of the key fob, while the light sirens should glow with a steady light, indicating that the object is armed, and the alarm loop is restored Disarm the object when the room is opened in the following order: 1) open the front door, while the light annunciators should switch to a flashing mode of operation; 2) go to the device at a distance of no more than 30 m and briefly press the button "1" of the key fob, while the device will switch to the switched off sirens mode; 3) call the monitoring station by the subscriber phone and inform the operator about the disarming of the object. It should be borne in mind that if the time from the moment the door is opened to pressing the button "1" of the remote control exceeds the set delay time, the sounder will turn on. 3 Checking the technical condition of the device 3.1 Checking the performance of the product This methodology is intended for engineers and technical workers and electricians of the fire alarm system servicing the technical means of security and fire alarms (TS FSA), checking the technical condition (input control), and includes checking the operability of the device with the purpose of identifying defects and assessing their technical condition. Non-compliance of devices with the requirements specified in this method is the basis for filing claims with the manufacturer and calling his representative to continue checking and resolving the issue of eliminating defects Checking the technical condition of devices is organized by laboratories and repair shops of security units and is carried out by service personnel who have studied the principle of operation of the device and this methodology and those who have qualifications of at least 3 categories of electricians of the OPS. The check is carried out under normal climatic conditions in accordance with GOST: 1) ambient temperature - () 0 С; eleven

12 2) relative air humidity - (45-80)%; 3) atmospheric pressure, mm Hg. (84-106.7) kPa The check is carried out according to the scheme of the general check of the device, which is given in Appendix D. The total time for checking the technical condition of one device is no more than 40 minutes. Notes 1 Connect and disconnect the wires during the tests with the device and the stand disconnected from the power supply. 2 All checks should be carried out taking into account the technical readiness time of the device, which is equal to 3 s. The device should be checked in the following sequence: a) check the condition of the packaging and unpack the device; b) check the scope of delivery in accordance with the operation manual of the ATsDR RE, the availability and composition of spare parts; c) make sure that there is no mechanical damage to the device case; d) by shaking the device, make sure that there are no foreign objects inside it; e) check the fastening of the terminal blocks; f) check the presence, compliance of the rating and serviceability of the device fuses; g) check the compliance of the device number and the date of issue specified in the operating manual. Check the basic technical characteristics of the device according to the general checkout scheme (Appendix D) Set the switches S1, S5 on the stand to the off position. Connect the stand to the AC mains. Turn on the mains switch of the stand and set the device supply voltage (220 ± 5) V using the TV1 variator, monitoring it with the PV3 voltmeter. Turn off the POWER switch. Switch on the direct current source G1 and set its output voltage (12.0 ± 0.5) V, monitoring it with the PV1 voltmeter. Note - In all modes, pressing the button "1" of the remote control is accompanied by a short, for a time of 0.05 seconds, turning on the sounders. Turn on the NETWORK switch of the general test stand. The built-in indicator of the device, indicators of the monitoring station stand, LAMP, INDICATOR should glow with a steady light, the CALL, SIREN indicators should not light up. After a time, not less than 2 minutes after turning on the POWER switch, press briefly (not less than 0.5 s) the button "2" of the key fob. If the device is operating correctly, the monitoring station stand indicator should turn off, the LAMP, INDICATOR indicators and the built-in indicator of the device should glow with intermittent light, the CALL and SIREN indicators should turn on. Press briefly (at least 1 s) button "1" of the remote control. If the device is operating correctly, the monitoring station stand indicator should turn on, and the LAMP, INDICATOR, BELL, SIREN and built-in indicator of the device should turn off. Press and hold button "2" of the remote control. If the device is operating correctly, the monitoring station stand indicator should turn off, and when the "2" button is released, it should turn on. Press briefly (at least 1 s) button "1" of the remote control. The built-in indicator of the device, indicators of the monitoring station stand, LAMP, INDICATOR should glow with a steady light, the CALL, SIREN indicators should not light up. Press and release button 12

13 "2" key fob. For the time the button is pressed, the monitoring station indicator should turn off, and the LAMP, INDICATOR indicators and the built-in indicator of the device should glow with intermittent light. After a time, not less than 2 minutes. after pressing button "1" of the remote control, briefly press the START button of the generator of short-term signals, and after a time of no more than 2 seconds - button "1" of the remote control. First, the built-in indicator of the device and the LAMP, INDICATOR indicators should glow with intermittent light, the monitoring station indicator must turn off, and after pressing the key "1" of the remote control, the built-in indicator of the device and the LAMP, INDICATOR indicators must turn off, the monitoring station indicator must turn on. Indicators of the CALL, SIREN stand should not be switched on. Turn off the NETWORK switch for the stand Turn on the NETWORK switch for the stand and at the same time turn on the stopwatch. The built-in indicator of the device, indicators of the monitoring station stand, LAMP, INDICATOR should light up, indicators CALL, SIREN should not light up. Every 10 s, briefly press the breaker switch of the stand. Record the time until the monitoring station indicator permanently turns off and the CALL, SIREN stand indicators turn on, which must be at least 2 minutes. Measure, using a stopwatch, the time when the CALL, SIREN indicators turn on, which should be at least 2 minutes. Using a stopwatch, measure the blinking frequency of the built-in indicator of the device and indicators LAMP, INDICATOR of the stand. Determine the frequency as the quotient of dividing the number of flashes by the selected time (10 s). When the instrument is operating correctly, the blinking frequency is 1 Hz. Turn off the mains switch of the stand. Press the OPEN switch and turn on the mains switch of the stand. The indicators of the monitoring station stand, CALL, SIREN should not light up, the indicators LAMP, INDICATOR and the built-in indicator of the device should glow with intermittent light. Using voltmeters PV4 and PV2, measure the voltage in the AL and the power supply circuit of the detectors, which, respectively, should be (24 ± 2) V and (12 + 1.2-1.8) V. After a time, no more than 1 min after switching on of the NETWORK switch, press the OPEN switch of the bench. If the device is working properly, the indicators of the monitoring station stand, LAMP, INDICATOR, the built-in indicator of the device should glow with a steady light, the CALL and SIREN indicators should not light up. Using voltmeters PV4 and PV2, measure the voltages in the AL and the power supply circuit of the detectors, which, respectively, should be (21-24) V and (12 + 1.2-1.8) V. Press the stand CLOSE switch. If the device is working properly, after a time of no more than 2 s, the indicators of the CALL, SIREN stand should turn on (glow with a steady light) for a time of 2 minutes, the monitoring station indicator should turn off, the LAMP, INDICATOR indicators and the built-in indicator of the device should shine with intermittent light. Press the switch MEAS.I of the stand. Using the PA2 milliammeter, measure the current in the loop, which should be no more than 20 ma, and using the PV2 voltmeter, the voltage in the detector supply circuit, which should be (12 + 1.2-1.8) V. Press the MEAS.I and CIRCUIT switches stand. The operating mode of the monitoring station stand indicators, LAMP, INDICATOR, BELL, SIREN and the built-in indicator of the device should not change. Turn off the CHAIN ​​switch of the stand. 13

14 Include in the open circuit between the PA2 milliammeter and contact XT2: 8 of the device the output contacts of the relay "Device for checking the timing parameters of the AL" (UP), the diagram of which is given in Appendix D. Connect the power circuits of the device to the direct current source G1 of the general test stand. Using the R3 UP potentiometer (see Appendix D), set the loop break time to 50 ms, controlling it using a frequency meter (the break time setting error is no more than 2%). Turn on the NETWORK switch of the stand. The indicators of the monitoring station stand, LAMP, INDICATOR and the built-in indicator of the device must glow with a steady light, the indicators of the CALL, SIREN stand must not glow. After a time of at least 2.5 minutes after turning on the POWER switch, press the S1 UP button. The device should remain in standby mode of operation, the nature of the indication should not change. Turn off the CHAIN ​​switch of the stand. Using potentiometer R3 УП, set the loop break time to 70 ms (setting error no more than 2%). Check the absence of a jumper (jumper) in the pin connector located on the control panel board. Turn on the NETWORK switch of the stand and after a time of at least 2.5 minutes press the S1 UP button. The device should switch to the alarm mode of operation, the built-in indicator and indicators of the stand LAMP, INDICATOR should shine with an intermittent light. After a time of at least 30 s after pressing the S1 UP button, the indicators of the CALL, SIREN stand should turn on for 2 minutes. Turn off the mains switch of the stand. Turn off the indicators LAMP, INDICATOR, BELL, SIREN from the stand and turn on the mains switch. Measure the current consumed by the device with a PA3 milliammeter, which should be no more than 55 mA. Turn on the stand RESERVE switch and turn off the mains stand switch. The device must remain in standby mode - the indicator of the monitoring station stand must light up. Measure the current consumed by the device with a PA1 milliammeter, which should be no more than 100 mA. Using voltmeters PV4 and PV2, measure the voltage in the AL and the power supply circuit of the detectors, which, respectively, should be (18-24) V and (12 + 1.2-1.8) V Make an entry in the log of repairs and incoming control of the alarm system about check results. 4 Current repair 4.1 The list of instrumentation required for maintenance and repair in a workshop is shown in Table 4, the approximate consumption of components and materials required for maintenance and repair of the device is in Table 5. List of the most common or possible malfunctions and methods their elimination is shown in Table 6. fourteen

15 Table 6 Name of malfunction, external manifestation and additional symptoms Probable cause Method of elimination 1 When the power source is turned on, the light annunciators do not light up 2 When the power source is turned on, the fuse fails 3 In the alarm mode, the buzzer does not turn on and / or the alarm signal is not issued on monitoring station 4 Pressing the buttons "1" and "2" of the key fobs does not switch to standby mode, the mode of switched off sirens, alarm mode No voltage in the network Faulty mains power supply fuses in the device Faulty signal lamp Faulty transistor VT1 Short circuit in the secondary or primary circuits transformer T1, breakdown of diodes of the VD7 VD10 bridge, breakdown of capacitor C5 The bell is faulty. Defective transistor VT3. Defective relays K3, K2 Faulty battery in the key fob Inconsistency of the code messages of the key fobs with the codes stored in the microcontroller memory of the device Check the presence of voltage in the network Replace the fuses Replace the signal lamp Replace the transistor VT1 Check the serviceability of the transformer T1, diode bridge VD7 VD10, capacitor C5. Replace defective elements Replace defective elements Replace the battery in the key fob Register key fobs according to p. When performing repair operations, it is necessary to comply with the requirements for the protection of integrated microcircuits from static electricity according to OST Dangerous value of electric potential +100 V. 4.3 The electrical circuit diagram and the list of elements are given in the repair manual for ADSDR RS supplied under a separate contract. 5 Maintenance 5.1 Maintenance of the device is carried out according to the scheduled preventive system, which provides for annual maintenance. 5.2 Work on annual maintenance is carried out by employees of the service organization and include: 1) checking the external condition of the device; 2) performance check in accordance with clause of this manual; 3) checking the strength of fixing the device, light and sound annunciators, the condition of external installation wires, installation connections; 4) checking the AL parameters; 5) checking the operating time of the sound annunciators and the switching frequency of the light annunciators. 15

16 APPENDIX A (mandatory) Overall and installation dimensions

17 APPENDIX B FUNCTIONAL DIAGRAM OF THE CENTRAL STATION INSTRUMENT Power supply of the AL Reference voltage divider Node of the signal relay Node of the control of the AL status Indicator of the device status Node of the delay of switching on of sound annunciators XT3 Node of programming of key fobs Single-chip microcontroller Node of light annunciators, annunciator and indicator External light annunciator S1 opening the case Sounder unit Remote sounder Siren S2 Receiver module Loop power supply ~ 220 V ~ 20 V Stabilizer 24 V Converter Input unit Voltage rectifier 12 V voltage stabilizer 5 V 5 V 17

18 APPENDIX B WIRING DIAGRAM OF THE DEVICE Control Panel "Signal-VK" isp. 02 XT1 Cont. Circuit Mains ~ 220 V Bell Lamp 6 Mains ~ 220 V 5 Mains ~ 220 V 4 Lamp 3 Lamp 2 Bell 1 Bell Remote siren DC (12 V, 50 ma) Cont. XT2 Circuit 12 Indicator + 11 Indicator - 10 Reserve +12 V 9 Reserve 12 V 8 Loop + 7 Loop - 6 Panel 5 Panel V (12V, 40 ma) 3 0 V 2 Siren + Siren (12V, 300 ma) 1 Siren - R - resistor C2-33-N-0.5-8.2 kΩ ± 5%; I1 - a detector with normally closed contacts; I2 - a detector with normally open contacts or a detector of the "Window", "DIP", "Volna-5", "Foton-8" types 18

19 APPENDIX D Scheme of general verification of the device HL4 "LAMP" HL2 "CALL" Control Panel "VK signal" isp. 02 ХТ2 Circuit 6 ~ 220V mains 5 ~ 220V mains 4 Lamp 3 Lamp 2 Bell 1 Bell Cont. R3 "INDICATOR" R6 R4 R7 R5 R10 ХТ1 Cont. Circuit 12 Indicator + 11 Indicator - 10 Reserve +12 V 9 Reserve -12 V 8 Loop + 7 Loop - 6 Panel 5 Panel V 3 0 V 2 Siren + 1 Siren - R8 R9 F1 - fusible insert VP1-1 1 A 250 V; HL1, HL3, HL5 - single indicator AL307 BM; HL2, HL4 - incandescent lamp B; R1 - resistor C2-33H-0, Ohm ± 5%; R2 - resistor C2-33N-0.25-8.2 kΩ ± 5%; R3 - resistor C2-33N-0.5-2 kΩ ± 5%; R4 - resistor C2-33H-0, Ohm ± 5%; R5, R6 - resistor C2-33N-0.5-2 kΩ ± 5%; R7 - resistor C2-33H-0, Ohm ± 5%; R8 - resistor C2-33H Ohm ± 5%; R9 - resistor PEV-7.5-39 Ohm ± 5%; R10 - resistor C2-33H Ohm ± 5%; S1 ... S5 - PKn61 N switch; TV1 - single-phase variator RNO-250-2; VD1 - Zener diode KS168A; G1 - constant current source B5-30; PV1 ... PV4 - voltmeter V7-22; PA1 ... PA3 - combined device C Note - Instead of the indicated devices, Trinkets similar in characteristics and accuracy class can be used

20 APPENDIX E Device for checking the time parameters of AL + (24 ± 3) V HL1 To the frequency meter Capacitors C1- K V-0.1 mf ± 10% C2 - K V-3.3 mf ± 10% C3 - K pf ± 10% С4 - К В-470мф-В Single indicator HL1 - АЛ307БМ Relay К1 - relay RES-82 RS4.569 Resistors R1, R2 - С2-33N-0.25-1 kΩ ± 10% R3 - SP4-1a-15 kΩ R4 - С2-33Н-0, com ± 10% R5 R7 - С2-33Н-0.25-10 com ± 10% R8, R9 - С2-33Н-0.25-2 com ± 10% R10 - С2-33Н- 0.25-10 kΩ ± 10% R11 - С2-33Н-0, Ω ± 10% R12 - С2-33Н-0.25-15 kΩ ± 10% Semiconductor diodes VD1, VD2 - КД510А VD3 - Д814Б VD5, VD6 - KD510A Transistors VT1 VT3 - KT3102 BM 20


GIPPO-1M security and fire control device The GIPPO-1M fire control and fire control device is designed to monitor the state of the alarm loop (AL), both in stand-alone mode with

1 General information FIRE ALARM CONTROL DEVICE PPKOP 051-1-3 UOTS-1-1A USER MANUAL Thank you for choosing the UOTS-1-1A device manufactured by NPO Siberian ARSENAL. You purchased

Control panel Fire and security PPKOP 051-1-3 УОТС-1-1А OPERATION MANUAL CONTENTS GENERAL INFORMATION ... 2 INDICATION OF SAFETY MEASURES ... 2 TECHNICAL DATA ... 3 INSTALLATION AND PREPARATION PROCEDURE

TERMINAL DEVICE UO-2 OF THE "FOBOS-3" NOTIFICATION TRANSMISSION SYSTEM Operation manual АЦДР.425632.002 OM 2002 Contents Page. Introduction 1 1 Description and operation of the product 1 1.1 Purpose of the product

RESERVED POWER SUPPLY OF RIP-24 FSA EQUIPMENT version 01 АЦДР.436534.002-01 ME61 label 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for RIP-24 FSA equipment

ALARM-CONTROL DEVICE SECURITY-FIRE QUARTZ (UOTS-1-1A) option 3 OPERATION MANUAL BB02 UP001 Dear customer! Thank you for choosing our products. In the creation of modern high-quality

DEVICE ALARM - CONTROL SECURITY AND FIRE Control Panel 0104059-1-2 "SIGNAL - SPI" АЦДР.425513.003 OM Operation manual Contents Page. Introduction 1 1 Description and operation of the product 1 1.1 Purpose

ALARM CONTROL DEVICE PPCOP 0104059-1-1 / 01 "SIGNAL-VKP" Operation manual ATsDR.425513.001-01 RE S O D E R G A N I E Introduction 3 1. Description and operation of the device .. .3 1.1 Purpose

ISO "Orion" Fire control and reception device This installation manual contains instructions that allow you to perform the basic steps for the installation and preparation of the "Signal-20M" device for operation.

ALARM CONTROL DEVICE PPCOP 01004059-4-1 / 03 "SIGNAL-VK-4P" Operation manual ATsDR.425513.001-03 OM CONTENTS Introduction 3 1. Description and operation of the product ... 3 1.1 Purpose

TERMINAL DEVICE UO-2 OF THE "FOBOS-3" NOTIFICATION TRANSMISSION SYSTEM Operation manual АЦДР.425632.002 OM 2007 CONTENTS Page. Introduction ... 4 1 Description and operation of the product ... 4 1.1 Purpose of the product ... 4

ALARM-CONTROL DEVICE SECURITY-FIRE QUARTZ OPTION 1 OPERATION MANUAL UP001 General information 1 18 Thank you for choosing the "QUARTZ" device manufactured by NPO "Siberian ARSENAL". This product

ALARM-CONTROL DEVICE SECURITY-FIRE QUARTZ option 3 OPERATING MANUAL SAPO.425513.006 RE Certificate of conformity С- RU.ПБ01.В.00877 Dear Customer! Thank you for choosing our

POWER SUPPLIES BBP-0, BBP-0, BBP-0, BBP-00 TU 00 CERTIFICATE OF CONFORMITY CU RU С-RU.AL.B.0 Series RU 00 PASSPORT INTRODUCTION

POWER SUPPLY BBP-24 TU 4372 002 63438766 14 CERTIFICATE OF CONFORMITY ТС RU С-RU.AL16.B.02558 Series RU 0228076 PASSPORT INTRODUCTION

POWER SUPPLY BBP-20M TU 4372 002 63438766 14 CERTIFICATE OF CONFORMITY ТС RU С-RU.AЛ16.B.02558 Series RU 0228076 PASSPORT INTRODUCTION

POWER SUPPLY BBP-200 ТУ 4372 002 63438766 14 CERTIFICATE OF CONFORMITY ТС RU С-RU.АВ24.B.04521 Series RU 0477342 PASSPORT INTRODUCTION

RESERVED POWER SUPPLY RIP-12 version 05 (RIP-12-8 / 17M1) Label АЦДР.436534.001-09 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply RIP-12 version 05 (RIP-12-8 / 17M1)

POWER SUPPLIES BBP-0, BBP-0, BBP-0, BBP-00 TU 00 CERTIFICATE OF CONFORMITY ТС RU С-RU.AB.B.0 Series RU 0 PASSPORT INTRODUCTION

Operating instructions Redundant without battery power supply RIP-12 isp.03 for battery 7 Ah 242872 Prices for goods on the website: http://www.vseinstrumenti.ru/electrika_i_svet/sistemy_bezopasnosti/sistemy_pozharno-

ISO "Orion" Fire alarm control panel "Signal-20P isp.01", "Signal-20P SMD"

RESERVED POWER SUPPLY OF OPS "RIP-12" EQUIPMENT isp. 05 Label АЦДР.436534.001-09 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for the RIP-12 fire alarm system

POWER SUPPLY MIP-12 ver.02 (MIP-12-1 / P3) Label АЦДР.436434.002 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Power supply MIP-12 ver.02 (MIP-12-1 / P3) ( hereinafter MIP) is intended

ISO 9001 RESERVED POWER SUPPLY OF EQUIPMENT OPS "RIP-12" isp. 02P Label АЦДР.436534.001-13 ET PB01 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for the equipment

Control panel Fire and security QUARTZ option 1 OPERATION MANUAL CONTENTS GENERAL DATA ... 2 TECHNICAL DATA ... 3 DEVICE DESIGN ... 4 INSTALLATION PROCEDURE ... 5 PREPARATION FOR WORK ... 5

ISO 9001 REDUNDANCED POWER SUPPLY OF EQUIPMENT OPS "RIP-12 isp. 06 "Label АЦДР.436534.001-12 ЭТ ПБ01 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply of the equipment

ISO "Orion" Fire control and reception unit "Signal-20P isp.01", "Signal-20P" This installation manual contains instructions for performing basic installation and preparation

PASSPORT for uninterruptible power supply BBP-100 POWER SUPPLY BBP-100 TU 4372 006 63438766 11 CERTIFICATE OF CONFORMITY ROSS RU.HP28.B07734 PASSPORT 1. INTRODUCTION This passport is intended for study

1 GENERAL INFORMATION Thank you for choosing a device of the "Granite" family, manufactured by NPO "Siberian Arsenal". This product will provide reliable protection of your facility from intrusion and fire. Receiving and control device

DEVICE FOR INTERFACING RS-232 INTERFACES AND REPEATER OF NOTICE TRANSMISSION SYSTEM "FOBOS" "USI-Phobos" АЦДР.426469.009 РЭ Operation manual Contents Page. 1 Product description and operation 1 1.1

SECONDARY POWER SUPPLY RESERVED BBP-30 V.4 TS Technical data sheet Redundant secondary power supply with filtering from mutual influence of consumers on each channel

"APPROVED" Head of SKB ITs A.A. Martsinkevich "_15_" 060 2001g Control unit BU 3 Instructions for setting and checking PMEA.656116.403 I1 Contents 1. Introduction 3 2. Technical data of the control unit

ISO "Orion" Voice announcement unit Rupor isp. 01 Installation manual АЦДР.425541.001-01 ИМ These installation instructions contain instructions for performing basic installation and

K ARIA VOICE SIGNALING SYSTEM I. Wiring diagram of 9, 12, 15, 18, 21, 24 and 27 voice sirens and P. Terminal resistor rating = 1.5 kΩ ± 5%. VOICE ALARM UNIT to OPERATING INSTRUCTIONS

ALARM CONTROL DEVICE SECURITY - FIRE Control Panel 0104059-6-1 "Signal VK-6" АЦДР.425513.006 OM Operation manual CONTENTS Introduction 1 1 Description and operation of the product 1 1.1 Purpose of the product 1

Ministry of Internal Affairs of the Russian Federation Federal State Institution "Scientific Research Center" Okhrana "Novosibirsk Branch (NF Scientific Research Center" Okhrana ") 43 729 AC voltage stabilizer

SWITCHING DEVICE UK-VK UK-VK ver.10 UK-VK ver.11 UK-VK ver.1 UK-VK ver.13 UK-VK ver.14 UK-VK ver.15 Label АЦДР.4641.00 ET 1 BASIC TECHNICAL DATA 1.1 General 1.1.1 This label

Operation manual Pulsed secondary power supply source OPTIMUS-1230-OD Secondary power supply source OPTIMUS 1230-OD ARGP.435520.003TU is designed to provide power supply

PASSPORT for an uninterruptible power supply unit BBP-20, BBP-30 POWER SUPPLIES BBP-20, BBP-30 TU 4372 001 63438766 12 CERTIFICATE OF CONFORMITY ROSS RU.HP28.V07734 CERTIFICATE OF CONFORMITY ROSS.V.

An insert for the operation manual for the Inflow-A-KOP-02 LIPG 423141.022 OM 1. BASIC INFORMATION This insert for the operation manual for the Inflow-A-KOP-02 LIPG 423141.022 OM is a document certifying

REDUNDANT POWER SUPPLY OF EQUIPMENT OPS RIP-24 isp.01 (RIP-24-3 / 7M4) Label АЦДР.436534.002-01 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply of equipment