Fire and security control panel S2000M. Where to buy S2000 in Tyumen at the best price? Is it difficult to program s2000m

    The following features have been added:
  • Added a new password attribute "duress code". When an object is controlled by a duress code, it is put into the Duress alarm state. "Duress" is shown as an alarm state if the "PAN" alarm setting is set to "ALARM SOUND" or "ALARM SILENT", and is hidden if this setting is set to "NOT ALARM". When the partition is disarmed by the duress code, the DURATION REMOVED event is generated. The "Duress code presented" event is supported, which sets the "Duress" alarm state for the "reader" object (designed to generate an alarm when accessing the duress code in the ACS). This alarm is cleared by the manual command "Clear alarms". The "Duress" state controls the outputs with the programs 54 "Enable upon attack" and 55 "Disabled upon attack" ("Panic" includes the "Duress" and "Silent alarm" states).
  • The function of controlling one presentation of the TM key / card to the reader has been added. For this, the access levels now have the "Control style" attribute, which takes two values: 1) "Show state, then control"; 2) "Manage at once". If the control style is set to "Control immediately", then when a key with section control rights is presented to the reader, the section is controlled immediately. This management style is suitable for users with rights to manage one section.
  • Added alarm settings for events:
    • "Assault" (includes "Duress" and "Silent alarm");
    • "Entry alarm".
  • Added relay control programs:
    • 54 "Enable when attacking";
    • 55 "Turn off when attacked";
    • 56 "Lamp 2";
    • 57 "Siren 2".
    The "Lamp 2", "Siren 2" programs are intended for radio broadcasters with autonomous power supply. Added a setting that allows you to control relays with programs 1 - 8 with a delay during "Fire 2" (as in "S2000M" version 2.07).
    Changes to existing features:
  • For the convenience of using "S2000M", the user interface of the main operating mode has been redesigned:
    • the number of actions required to view alarms, fires, starts, faults has been reduced. Changed the display of the number of sections with alarms, fires, starts, faults;
    • the proposed control commands better correspond to the state of the partition and its type (for example, a disarming command is proposed for the security partition in the alarm);
    • the events displayed on the screen in standby mode do not interfere with entering the password with the numeric buttons.
  • Added display of the number of sections containing actuators that are locked or are in manual control mode (automatic disabled), added viewing of sections with automatic states "Blocking" and "Manual control" ("Automation disabled"). A filter by the "Blocking" event type has been added to the event log;
  • Setting up the broadcasting of events for the "S2000 Panel" object in the PProg program now affects only the operational display of events on the screen, and all events are available in the log. This makes it possible to disable the online display of events. When the display of events is turned off, the indication of the state of the object - the presence of alarms, fires, starts, stops, faults and outages - is preserved.
  • The user number has been added to the "Partition taken" and "Partition disarmed" events, if the partition (partition group) is armed or disarmed not entirely, by a command to control the partition, but by parts. Examples:
    • the section (group) is armed (disarmed) as a result of local control of the loops of this section (arming or disarming with the keys recorded in the control and monitoring unit "S2000-4", "Signal-10");
    • a group of partitions is armed (disarmed) as a result of arming (disarming) the partitions of the group. Also made the formation of the "Section removed" event when it is disabled. These changes are useful when using Ademco Contact ID or LARS messaging.
  • Added two parameters to the LARS protocol settings: which user number to send in the "partition taken" and "partition removed" events if the user number is not known, and which user number to send if the user number in the event exceeds the maximum possible value. The default settings of these parameters correspond to the tactics of "S2000M" version 2.06: the "partition taken" and "partition removed" events are not transmitted if the user is unknown, and events with a too large user number are transmitted with the maximum allowed user number. The tactics of "S2000M" version 2.07 can be obtained by setting "1" as the number for an unknown user.
  • The names of the events have been changed: "WATER LEAKAGE" to "FLOODING", "NO WATER LEAKAGE" to "RECOVERY DZ", "OVERREG.RIP DEVICE" to "CURRENT OK".
    Bugs fixed:
  • It was possible a single false switching on of the relay after configuring by the PProg program, if the relay control programs were changed.
  • Fixed a bug in the "input loops" function. Eliminated the conflict of "input loops" configured simultaneously in the "S2000M" and the receiving-control unit (with the simultaneous setting, the "input loops" will work according to the settings of the receiving-control unit).
  • The event with the result of the operation was not displayed when the AL control panel was directly controlled (with a password with access level 253 - 255).
  • The "Partition taken" event was not generated if the partition was armed with a key with AL control rights (with a key written in the "S2000-4" or "Signal-10" control panel), and the partition had an alarm with a delayed arming for protection. The messages "Section taken" / "Section removed" might not be generated if some of the section inputs were set / removed by AL control scripts.
  • If the user first selected the action with the "RESET", "START", "STOP" keys or pressed the context menu key, then he identified himself (entered the password) and then exited the section view with the " & times", the message" Invalid section "might have been displayed.
  • There could be no initial indication of the state of executive devices (outputs of the "technological equipment" type) on the "S2000-BI / BKI" after the withdrawal of "S2000M" from the programming mode until the state of the executive devices changed.
  • The transmission of control requests from "S2000-K" and "S2000-KS" to the "Orion Pro" workstation did not work when the "CENTER CONTROL" parameter was enabled.
    Compatibility Details:
  • Configuring with "Pprog.exe" version 3.03 build 1 or higher.

Fire extinguishing control device S2000-ASPT, control device for water fire extinguishing station Potok-3N, relay modules S2000-KPB and S2000-SP1, voice warning device for fire Horn, system status indication units: S2000-BKI, S2000-BI, S2000-PT and S2000-BI isp.01, devices for transmitting notifications via the S2000-IT telephone line and the Orion UO GSM-channel, an S2000-2 access controller, additional remote keypads S2000K and S2000-KS, as well as in the ISO ARM "ORION" and "Orion Pro" systems.

Addressable receiving and monitoring consoles of the S2000 series (analog and addressable alarm loops) have stable characteristics and belong to the category "Universal alarm systems".

Control of up to 127 devices (Bolid address system) connected to the console via RS-485 interface;

Display on the LCD (liquid crystal) indicator of events occurring in the system;

Storing events in a non-volatile buffer with the ability to view them on the display and print them on a printer with a serial RS-232 interface;

Signaling alarms and events with a built-in sound signaling device;

Control of arming / disarming and monitoring the status of alarm loops from the control panel;

Programming the configuration parameters of devices, printing the configuration on a printer, setting the addresses of devices and addressable devices;

Restricting access to control and programming functions using passwords.


Specifications S2000M (Bolid)

NAME OF PARAMETER PARAMETER VALUE
The number of devices and devices ISO "Orion" connected to the RS-485 line, no more
RS-485 interface 1
RS-485 communication line length, no more 3000 m
RS-232 interface 1
Number of devices connected to the RS-232 output

1
(computer with AWP, printer, ATS100 or TRX-150 radio transmitter (via a converter) or RS-202TD radio transmitter)

RS-232 communication line length, no more 20 m
Number of alarm loops and addressable detectors grouped into sections, no more 2048
Number of relay outputs controlled in automatic mode, no more 256
Number of sections, no more 511
Number of section groups, no more 128
Number of user passwords, no more 2047
Output over voltage protection 2 steps
Event log size 8000
Liquid crystal indicator 2 lines x 16 characters, backlit
Nutrition from a redundant DC power supply
Supply voltage 10.2 to 28.4 V
Average current consumption in standby mode at a supply voltage of 12 V / 24 V 60 mA / 35 mA
Maximum current consumption in alarm mode at 12 V / 24 V supply voltage 120 mA / 65 mA
Working temperature range from minus 10 to +55 ° C
Sheath protection degree IP30 (when mounted on a wall)
Weight, no more 0.3KG
dimensions 140x114x25 mm
Type of connection to the device screw terminal block, wire from 0.2 to 1.5 sq. mm
Mounting method wall mounted

A complete list of functions of the fire control panel Bolid S2000M:

The ability to combine individual fire alarm loops into sections, while supporting a larger number of loops than the previous analogue S2000, which allows it to be used at especially large facilities;

Display of text names on a large LCD display, sections and usernames in the event log. The display string is 32 characters long. Now it is possible to set a text description of users, partition groups, partitions and fire alarm loops;

Increased maximum number of system users (PIN and TouchMemory);

Sections can be combined into section groups. This allows group control of arming and disarming. Any group can include any section of the system;

Control of taking, removing and monitoring the state of system sections, both from the console and from the S2000-K keyboard, S2000-KS console and S2000-4 device. In this case, the control powers are delimited by passwords (control rights for arming / unsetting partitions are set for users and separately for each connected device).

Possibility of programmed automatic control of relay outputs of relay blocks S2000-SP1, S2000-SP2 and S2000-KPB tied to the state of the sections. Possibility to control the outputs of devices S2000-4, Signal-20P and Signal-20 series 02. and other ISO Orion devices. Possibility to control relay outputs with a preset delay time;

Management of displaying the states of sections on the S2000-BI and S2000-BKI display unit (and other display units);

The S2000M console transmits (duplicates) the events occurring in the system to the S2000-K keypads for displaying them on the indicator and the device for transmitting information over the telephone line (informant) S2000-IT;

For convenient logging of events and displaying the states of sections and loops of the security and fire alarm system, the monitoring and control panel can be connected to a personal computer with the "Orion Pro" workstation software;

Also, in the "programming" mode, the console can perform the function of a converter of RS 232 - RS 485 interfaces. This function allows you to configure the console and the devices of the Bolid address system connected to it;

The console has the ability to connect several subsystems of the security and fire alarm system based on the S2000M console to a personal computer with an "Orion" workstation;

S2000M, when disconnected from the PC, goes into offline mode and continues to work with the specified configurations;

Programming and configuration of the S2000M control and management console is carried out using the program (utility) "pprog.exe" or the "Database Administrator" program from the "Orion Pro" workstation, which can be downloaded from the official website of the Bolid company, or from the website of the ABars company. in the "Documentation" section (in the same place you will find the connection diagram and the passport of this network controller).

A wide range of BOLID brand alarm devices allows you to choose a model for any request and functionality. A large selection will delight companies engaged in the installation of fire and security alarm systems and their customers.

Although S2000M belongs to the category " inexpensive fire alarm consoles", it is reliable, like all other elements of the" Bolid "trademark.

Office alarm;
Security and fire alarms for cafes and clubs;
Signaling to the store;
Security systems for the warehouse and office premises;
Autonomous alarm system for an apartment, house or cottage;
Fire alarm for indoor car parks, garages and parking lots;
Comprehensive protection for government agencies (kindergartens, schools, other educational institutions)

When choosing, pay special attention to a careful study of the technical characteristics, the choice of suitable security detectors , fire detectors , special cable products... The devices of the S2000 line are one of the best in terms of price-quality ratio and are recommended for use in a wide range of security and fire alarm systems. All alarm control panels (SCP) of this brand can operate with most of the backup power supplies presented on this website.

Analogs S2000M and other devices similar in characteristics: S2000

Buy and order delivery of fire alarm systems to Moscow:

You can order and buy the S2000M remote control, as well as other Bolid products (their analogues, detectors, relays) through the fire alarm online store of our website, or order delivery and professional installation services in your premises in Moscow from the ABars company. (Attention, delivery is free for orders over 60 thousand rubles).