Automated temperature monitoring system and humidity in the building. Temperature monitoring systems Install an automated temperature and humidity monitoring system

testo saveris TM GSM module (to transmit alarm alert by SMS)

Type of equipment: Saveris base

Manufacturer: Testo AG, Germany

Model: Testo Saveris

A great set of devices have been developed for controlling microclimate parameters, but the TestoSaveristm system combines all the best of their advantages. TestoSaveristm is a reliable and universal device for long-term and centralized monitoring of data, the most important climatic parameters. The testosaverist is installed easily and quickly, but using radio modes or existing networks, disappears the need to interfere in the existing structure of the building. If the entered values \u200b\u200bare exceeded, the alarm automatically triggers that helps to take action to prevent damage. In this version of the TESTOSAURISTM system (GSM), alarm alert is possible via SMS, even with a not connected computer.

Warranty on Testo Saveris TM: 24 months.

Purpose of the TESTO SAVERIS system TM:

Continuous and long-term monitoring of the parameters of measurements of microclimate in rooms is especially necessary in museums, archives, laboratories and libraries due to the need to maximize the protection of valuable exhibits, and TestoSaveristm is an ideal choice for solving such tasks. It is also widely used in production, for quality control in the food industry.

The testo saveris TM system is listed in the state. Register of measuring instruments of the Russian Federation

Distinctive features of Testo Saveris TM:

  • Simple and easy to operate
  • Continuous and automated document documentation process of all measured results in format.pdf
  • Centralized output to the monitor of all measured data
  • To simplify data analysis and immediate reporting, special software for PC is attached
  • High-precision temperature and humidity measurement
  • Wireless, reliable transmission
  • Wide selection of probes for different applications
  • High versatility with radio or ethernet probes
  • Continuous monitoring, even with a temporary interruption of a radio signal
  • Transferring alarm via SMS using the GSM module
  • Additional emergency power elements for data security made measurements

TECHNICAL SPECIFICATIONS TESTO SAVERIS TM:

  • Memory: 40,000 values. on the channel (max. 10,160,000 values)
  • Dimensions: 225 x 150 x 49 mm
  • Weight: approximately 1510 g
  • Protection class: IP42
  • Material / Case: Molded Zinc / Plastic Pressure
  • Radio Frequency: 868 MHz / 2.4 GHz
  • Power (needed): Power supply 6.3 V DC; or through screw terminals 24 in AC / DC, power consumption
  • Power Element: Li-Ion Battery
  • Operating temperature: -10 ... +50 ° C
  • Storage temperature: -40 ... +85 ° C
  • Display: Graphic Display, 4 Control Keys
  • Interfaces: USB, Radio, Ethernet
  • External Radio Probe: Max. 15 probes can be connected directly through the radio interface, total max. 150 probes via radio, router, converter, Ethernet, Max. 254 channels
  • Relay Alert Module: Max. 1 A, Max. 30 W, max. 60/25 in DC / AC, normally closed or normally open contact
  • GSM Module: 850, 900, 1800, 1900 MHz besides Japan and South Korea

Completeness of the supply of testo saveris (set3):

  • TestoSaveris 2.4 GHz Monitoring System Base
  • GSM module for alarm alarm via SMS
  • Antenna on a magnetic stand
  • Five Wireless NTC Probe With Display
  • TestoSaveris router
  • Power supply for SAVERIS base
  • Power supply for Saveris router
  • SBE Personal Computer Software
  • USB cable

We offer you a software and hardware complex that implements centralized automated monitoring, registration and control of the microclimate on objects, regardless of their location. Information comes in real time.

Before installing constant sensors, follows carry out the temperature mapping of the objectwhich will allow you to identify critical points, as well as install, whether the room is suitable for the storage conditions of your products. This procedure allows you to detect storage zones with moisture drops and temperatures above extremely valid.

The data obtained will allow accurate to determine the place that is best suited for the placement of goods and the thermal sensors themselves for permanent and timely control of the microclimate. During the mapping procedure, we use a number of proven temperature recorders, it is produced three times a year - in summer, in winter and autumn (or spring), indoors where all engineering works are completed.

Our company offers you full system validation package, as well as the main approaches on its organization. Turning to us, you can be sure that you will get a high-quality service.

Software and technical measuring complex

Our company offers software and technical means of registration, monitoring and control of microclimatic parameters.

The package of services offered by us includes:

  1. Installation of equipment equipment.
  2. Pattern of premises by the temperature method.
  3. Validation of the entire supplied software and technical complex.
  4. Verification of sensors and temperature loggers and humidity level.

The company strives for the most complete satisfaction of the needs of our customers and partners. And the best proof of this is our price list with rates below market and reliable quality assurances confirmed by certificates of compliance with international importance.

Appointment of a software and technical measuring complex

One of the most remarkable products of the enterprise is a measuring system. This is an innovative software and technical complex (PTC) designed for highly efficient climate control on industrial facilities and organizations, whose activity is related to the sphere of pharmaceuticals.

The main function of the system is an automated collection, control, visualization and storage of data obtained during the study of the main microclum parameters - temperature and relative humidity.

The complex is indispensable in the work of pharmaceutical enterprises with infrastructure, including:

  1. Warehouses.
  2. Rooms with a cold and cool microclimate.
  3. Production workshops.
  4. Laboratory.
  5. Climatic, refrigeration and freezing chambers.

Helpful information: The PTC may include digital sensors or autonomous logs of relative humidity and thermal regime. Optional, i.e. By connecting additional analog or discrete sensors, the system supports the ability to measure a number of other microclimate parameters, for example, pressure jumps or gases concentration changes.

Depending on the software-technical composition and the needs of the consumer, the complex can be equipped with means of wired or wireless communication, incl. with access to the global network. Due to this, the complex allows you to organize a highly efficient centralized microclimate monitoring system at all objects of the served enterprise. Moreover, regardless of their location on the map, as well as remoteness from each other and from the dispatch center.

The main functions of the complex

The following functions are assigned to the hardware part of the PTC:

  1. Displays current measurement results on the SKPU module screens (Universal parameter control cabinet).
  2. Control of measured values \u200b\u200bfor working ranges with individual settings.
  3. Light sound alarm system with deviations of the parameters under study from regulatory values.
  4. SMS-alert with accidents, as well as re-send messages after restoring the normal mode.
  5. Duplication and storage of measurement results in the memory of autonomous loggers controlling the level of humidity and temperature.

As for the software, it has a configuration of the server / client, and its tasks are as follows:

  1. Recording current measurement results to MySQL database with unauthorized access.
  2. Representation of data obtained during measurements in tables and graphs.
  3. Displays the display of pop-up messages about the events under the control area (disorders of temperature and humidity, communication breaks, system warnings, etc.).
  4. SMS and E-mail newsletter on events taking place in control zones.
  5. Calculation and automatic installation of warning and emergency ranges.
  6. The delimitation of the access of employees of the enterprise to the sections where control measurements are carried out.
  7. Maintaining a detailed event log and registration of facility personnel.
  8. Planning and formation of reports (daily, decada, quarterly, seasonal, etc.), as well as computer analysis of data obtained during data research, followed by the provision of a general summary in PDF format.
  9. Export information obtained from sensors, loggers and other optional components of the complex in MS Excel formats (* .xlsx) and 1c (* .xml).
  10. Individual setup of TCP / IP and COM connections for all devices operating in the complex, as well as combining individual functions of these types of communication.
  11. Operational processing and analysis of data using a special registration and survey module.

Helpful information: The PTK operating system has an interface with excellent usability, which is outside the field of competition in the degree and quality of automation of workers and service and preventive processes.

PTK: Main advantages

In the supply of technological equipment and PTC components, the manufacturer provides free licenses for Software Packages "Server" and "Client". Making such a purchase, the user receives not only an impressive cost savings at the start of the business project, but also a reinforced concrete guarantee of the uninterrupted operation of equipment, communications and the operating system of the complex. And most importantly: since the functionality of the latter has no analogues in the global market, the purchase of the complex opens an extra-competitive spectrum of opportunities and prospects for business.

In addition to the temperature regime (in the range from -40 to +80 ° C) and the level of relative humidity (0 ... 100% RH) in the PTC control area includes voltage of the electrical network. Also, the complex is monitored by access to Shkpu and regime premises of the object being served. Control of other PTC parameters provides optional.

The list of the most notable advantages of "Gigotermon" is worth starting with:

  1. 4-year interval of equipment verification and general validation of the system.
  2. Opportunities for remote control of the activities of branches and subdivisions of the headquarters.
  3. Ease of installation, connecting and maintenance of equipment and communications PTK.
  4. Automated system setup procedure.
  5. Smart self-diagnostic system.

Helpful information: Specially developed a package of package of documents for the validation of the complex, as well as the basic methods of performing this procedure. As a result of the usability and profitability of the product, it was possible to raise the highest level, which beyond the most bold fantasies of possible competitors.

PTK equipment meets the regulatory requirements established for modern pharmaceutical industrial enterprises. At the same time, the complex fully satisfies the provisions:

  1. GMP / GDP / GSP standards for pharmaceutical facilities.
  2. Standard for the control of drug production and food products (FDA 21CFR part 11).

Also PTK complies with the rules put forward by the Ministry of Industry, relative to the organization of production processes in pharmaceutical enterprises, as well as quality control of products. Loggers used by the system are included in state registers of the SI of the Russian Federation and the Republic of Kazakhstan. This ensures the availability of this technology and in the domestic market, and on the trading platforms of the neighboring countries.

Technical Features Modules Shkpu

The parameter control cabinet universal as part of the complex is intended for:

  1. Connecting groups of temperature loggers, humidity sensors, pressure, etc. In an amount of from 1 to 15, 30 or 60 units as part of a monitoring and diagnostic unit.
  2. Visualization of data obtained during the microclimate monitoring process on the serviced area.
  3. Feeding light-sound signals when the controlled parameters deviates from working borders.
  4. Conversion of data and transfer them to the upper control level.

Inside the PKPU conveniently, compactly and neatly place all the components necessary for the PTC operation. To enter the module, sufficient:

  1. Reliable fasten it on the vertical plane of walls, columns or other layout details.
  2. Connect power.
  3. Route from Shkpu to server receiving and processing control data.
  4. Connect the number of sensors, loggers or other sensitive equipment required for efficient monitoring of the microclimate in the served premises.

A few control cabinets can work as part of one PTK - it all depends on the complexity and scale of the control and monitoring system of microclimatic parameters. In most cases, for one building, facilities or functional complex of premises of the serviced enterprise is enough of the SKPU module.

The hardware scheme is developed in accordance with the PTK design hierarchy. At the same time, the operational features of the control zone, as well as the prospects for the upgrade and functional expansion of the system serving a specific object, are taken into account.

In the package of the control cabinet included:

  1. Actually, the inspection and control cabinet.
  2. 4 pieces of mounting anchor bolts.

Depending on the needs of the user to organize the work of the complex, such components are ordered as:

  1. Temperature loggers and relative humidity of the DS1923-F5 series (are intended for monitoring climatic parameters in control zones with temperature regime -20 ... + 85 o C, have basic protection against moisture, dust and other aggressive operational factors)
  2. Loggers DS1922L-F5 (have frost-resistant, moisture-proof design and are designed to work in rooms with temperature regime -40 ... + 85 o C).
  3. Cable adapter 1W-2/3 format, incl. With a built-in temperature sensor required for connecting loggers and sensors to the head hardware of the SKPU.
  4. The light-sound signaling system intended for timely alerts responsible for the work of a complex of persons and personnel of an object on violations of the regulatory microclimatic regime in control zones.
  5. Service-set IBDLR-0-U to reprogram the loggers and reading the working data from them.

Characteristics of Shkpu and Loggers

To organize the work of the system of the complex, the manufacturer has provided 3 types of SKPU with dustless IP41. They differ in the maximum permissible number of connected loggers or sensors.

The smallest control cabinets - Shkpu-1 - allow you to organize room service with a total area of \u200b\u200bno more than 1000 square meters. Only one loop logger can be connected to such a module, designed to install 15 test measurement points, but when the electricity is disconnected, it can operate offline at least 4 hours.

Helpful information: The regulatory length of the loop is 100 m and it is not recommended to exceed it, because This entails an increase in the error of control measurements to an unacceptable level.

Shkpu-2 is controlled with a group of 30 loggers or sensors placed on 2 loops. Cabinets of this category are included in the PTK to maintain objects with an area of \u200b\u200bup to 2000 m.kv.

The most accomplished are SKPU-4. They allow you to expand the complex to 60 sensors, and the latter are already connected with 4 loops. This provides an increase in the total area of \u200b\u200bthe control zone to 4000 m.kv. The battery life of cabinets 2 and 3 categories is within 2 and 1 hour, respectively.

The results of current measurements of loggers operating in the complex are displayed on the Shkpu display. Work information is entered into the internal memory of the system and is exported to the nearest server over the Ethernet network by TCP / IP data transfer technology. PTK optionally supports a number of alternative data interfaces. If necessary, the complex can communicate with servers and clients of the complex by:

  1. Radio broadcasts in the range of 433 MHz.
  2. Available GSM solutions.
  3. The RS485 standard (data transmission is carried out by Ethernet, but by sending / receiving differential electrical pulses).
  4. Fiber optic lines.

Registration of temperature indicators and humidity levels in controlled premises are carried out autonomously. First of all, measurement results are entered into the loggers, designed for 8192 entries, after which they are sent to the server. Here they are entering the magazine and come to further processing.

Helpful information: Shkpu has restrictions on the connection of pressure sensors: the latter are optionally incorporated into the control and measuring system in the amount of no more than 4 units.

It remains to add that despite the difference in the functionality, the control cabinets of all three categories have the same dimensions (800 * 800 * 200) and the weight of 45 kg. The manufacturer recommends exploiting the SKPU as part of the temperature range of + 5 ... + 40 o C and with air humidity in the room not more than 93%. The discreteness of thermo measurements performed by the loggers of the system does not exceed 0.0625 o C, while the total error in measuring temperature and humidity lies within +/- 0.5 o C.

Medicinal preparations require special storage conditions. High humidity (above 60%) on a pharmaceutical warehouse leads to a damage of hygroscopic medicines: potassium acetate, dry extracts, antibiotics, glucosides, enzymes and many others.

The parameters of the microclimate for such premises are prescribed in the regulatory and technical documentation. To monitor and accurate maintaining specified values \u200b\u200bset special systems for controlling humidity on pharmusclad.

Regulations

The values \u200b\u200bof temperature and humidity in the case of storage of drugs are not regulated by one value. Parameters vary depending on the group of stored substances. Basic requirements are written in several documents:

  • guidelines for the maintenance of pharmaceutical developments - a local regulatory act, its own for each country;
  • pharmaceutical validation guide;
  • regulations on proper laboratory practice GLP;
  • regulations on the maintenance of clinical practice GCP;
  • gPP pharmacy practice regulations;
  • gSP warehouse practice regulations;
  • regulations on Distributor Practice GDP T.S.

Preparatory activities

For maximum efficiency of the system, a preliminary study of the warehouse is carried out by a temperature card. The information received will help a specialist to determine the location of the sensors, their exact number. At this stage of work on the territory of the complex placed that remove the testimony within 3-5 days.

Logger data of humidity and temperature Testo 175 H1

The purpose of the preparatory activities:

  1. Determination of temperature on a pharmaceutical warehouse, its dynamics on different sections.
  2. Determination of critical points in which the temperature and humidity differences are maximized.
  3. Obtaining accurate temperature values \u200b\u200bto assess its stability.
  4. Analysis of storage compliance with all requirements.

Hardware control system

To monitor humidity and temperature on a pharmaceutical warehouse, high-precision sensors of domestic production are established. The IVIT series devices are calibrated, have states of the ultrasound. Testing sensors is carried out at least once every two years.

Features of the devices:

  • sensors can be located at any distance from the server. Data transmission is carried out on a single MODBUS bus. The devices are combined into a local network;
  • you can get information in real time. From the computer you can go to the local network and get data from the sensors;
  • storage time of information 5 years. The server volume is sufficient, access to the archive is possible from any PC of the LAN;
  • built-in emergency alert system. With a strong deviation of a temperature or humidity from the specified values, an alert on the manager of the dispatcher is displayed, and messages are sent to the phones of responsible persons;
  • protection against interruptions in power supply. The monitoring system is connected to the backup power scheme, which provides its performance for 12 hours when the central network is disconnected.

Software component control system

The software allows you to set the range of permissible changes in temperature and humidity, set the timeout time interval for sensors, visualize the temperature card from each point.

Decision first. By based on the Masterscada system. The license redeems one time. Functional:

  • data accumulation;
  • output of emergency warnings;
  • displays information from sensors.

One of the local network computers is used as a server, the rest - to gain access to the data. Sending alerts by SMS produces using the GSM modem that is connected to the server.

Second decision. Providing a remote Internet server to collect and storing data. FarmClade employees receive identification numbers and passwords for authorization in the Personal Account. System Features:

  • the service is located on fault tolerant equipment;
  • availability of server 99% time;
  • storage time of information up to 5 years;
  • the cost includes alerts on accidents on SMS email;
  • providing services - 200 rubles for each connected sensor.

You can test the service by addresses: http://178.132.203.6/sensor Username and password Demo / Demo

It is possible to integrate the system of control with climate warehouse equipment to maintain the specified parameters in automatic mode. After all, it is not necessary to know a little for the preservation of drugs, what air humidity in the pharmusclad, it is important to prevent its deviations.

Modern monitoring and control systems offers Sensor-Tools. The servers of the company are located in St. Petersburg and Moscow.

For the delivery and installation of systems, contact us through the feedback form:

Temperature and humidity controllers are used in a wide variety of areas. The main element of the model is the sensor. Immediately the determination of temperature or humidity is carried out through the conductors. To manage the specified process, the processor and microcircuit are used. Modern modifications are available with probes. However, to learn more information about controllers and humidity, you should familiarize yourself with their types.

Types of devices

First of all, the separation is carried out by the type of conductors. To date, there are contact and needle devices. The first type allows you to measure the air temperature. Needle conductors are most often used to determine humidity on any subject.

Also, models differ in sensitivity. The market presents modifications of low, medium and high sensitivity. More separation occurs by the type of sensor. There are switched, distributing, wired and impulse modifications.

PTD 1 Model Overview

This temperature controller and humidity has two sensors. The control parameter at the instrument is 1.3 MK. Contacts The model has a wired type. To display the measurement results, the control unit is used on the display. In order to recharge the device, the battery is applied. The model has 20 measurements. The accuracy of temperature determination is 1.2%. You can buy a model for 4300 rubles.

PTD 2 controller

The specified air temperature controller is used most often in laboratory conditions. The distinctive features of the device are considered high accuracy of indications and sensitive contacts. The power supply in the device is applied with a microcircuit. It is also important to note that this controller is very compact. The maximum allowable operating temperature is 45 degrees. Contacts apply wired type. Display is used to display results. The sensor at the device is set by switching type. For the construction industry, the model does not fit. These temperature controllers price fluctuates around 5200 rubles.

Description Kotroller Extech

This controller and humidity is often used in the industrial sphere. A distinctive feature of the device is a high conduction rate. Electrodes are used to transmit the signal. Contacts The device uses a wired type. The model has two sensors. The error rate does not exceed 0.5%.

In the liquid medium, the device is prohibited. If we talk about structural features, it is important to mention a quality battery. The model has not many memory. If you believe the reviews of specialists, the protection system very rarely gives failures. For sale presented temperature measurement controller and humidity at a price of 4400 rubles.

Reviews about the model ADA ZHM 125

The specified temperature control controller and humidity is in demand in the construction sector. Among the features of the device, reviews celebrate compactness, as well as a high-quality detector. Conductors at the model are installed medium sensitivity. The microcircuit is provided with a catcher. The maximum allowable operating temperature is 30 degrees. Electrodes in the device are used with the condenser. Memory in the specified device is enough for 30 measurements.

The accuracy parameter of the readings is at a time of 0.4%. The battery at the controller applies a small capacity. For a liquid medium, the device does not fit. The housing at the controller is provided with the protection system of the RP20 series. To buy a model, the user is capable of price from 3500 rubles.

Review of the model ADA ZHM 133

This is an inexpensive and compact controller and humidity. Customer reviews are talking about the low error parameter. In this case, the sensor uses a switching type. In total, the model has one battery. Offline controller can work for about five hours.

The protection system at the case has a RR20 series. If you believe specialists, then failures in the microcircuit rarely occur. The control unit is set to five channels. For laboratory studies, the device does not fit. You can buy this temperature sensor controller at a price of 4200 rubles.

Opinion about the Dinteck controller

This temperature and humidity measurement controller is equipped with two sensors. To connect the device to the PC there is a connector. The battery is used only one. The system of protection at the case is provided by the RP21 series. The catcher is absent from the model. Thus, the control parameter at the device is not high. If you believe feedback, it does not often occur in the control unit. The model in the model is used with condensers.

Measurement accuracy does not exceed 0.2%. For laboratory studies, the specified controller is suitable. However, it is important to note that in the liquid medium it is prohibited. By sensitivity, the model does not differ from the previous devices. The maximum allowable operating temperature is 55 degrees. You can buy a temperature and humidity measurement kitroller for 3,800 rubles.

Description of the Kotroller Hydroeasy.

Specified temperature and humidity controllers are available for incubators of various manufacturers. In this case, the sensor applies switching type. In total, the model has two capacitors. Contacts are standardly used wired type. Calibration at the controller does not take a long time. The memory of the device is enough only for 15 measurements. The maximum allowable operating temperature is about 45 degrees. The battery in this case is designed for 360 mAh. Enough for about 3.5 hours of work. The presented temperature and humidity measurement controller is sold at a price of 3600 rubles.

Reviews about the model ZFM 100-4

This is a professional and cheap controller measurement controller and humidity. Among the model features, reviews mention a high-quality sensor. The conductivity parameter does not exceed 1.4 MK. The display in the device is 3.5 inches. If you believe experts, the failures in the microcircuit occur infrequently.

The maximum allowable operating temperature is 45 degrees. The hull protection system is provided by the RP22 series. The memory of the device is enough for only 14 measurements. The error rate does not exceed 0.5%. Electrodes in this case are connected to the contactor. It is worth today this controller for measuring temperature and humidity of about 4600 rubles.

ZFM 100-5 Model Overview

Among the builders are very popular with these temperature and humidity controllers. Among the distinctive features of the model should mark a quality control unit. In this case, the display is used by 3.5 inches. The hull protection system is provided by the RP22 series. The conductivity parameter does not exceed 1.4 MK. Contacts in the device are installed wired type.

If you believe experts, the failures in the microcircuit are rarely observed. The error parameter at the controller does not exceed 0.4%. The permissible temperature level is 50 degrees. Model memory is enough for 35 measurements. According to reviews, the model is very quickly calibrated. To buy this temperature and humidity measurement controller, the user is capable of price from 4400 rubles.

Opinion on the TECNIX 590 controller

These temperature controllers and humidity are used in the construction and chemical industry. Among the distinguishing features of the modification, the reviews allocate a high-quality control unit. The microcircuit is used with wired diodes. It is also important to note that the model has a probe. The conduction indicator at the controller is 1.2 MK.

The display is standard for text type. The calibration function for the device is available. The permissible temperature level is 40 degrees. If you believe the reviews, the protection system at the body is set high quality. The catcher in this case is missing. Buy temperature controller and humidity in the store can be 3700 rubles.

Description of the TECNIX 600 Kotroller

The specified digital temperature controller is sold quite compact sizes. In total, the device has two sensors. The conductivity parameter of them is 1.3 MK. It is also important to note that the model has an electric catcher. Contacts are standardly used wired type.

The housing protection system is used by the RP22 series. The permissible temperature threshold is 55 degrees. Professional reviews suggest that failed in the microprocessor rarely occur. The model memory is enough for as many as 30 measurements. The standard set of the controller has two batteries. You can buy a model in a specialized store for only 3400 rubles.

Production and trading warehouses, production buildings in which the optimal temperature standards and relative humidity, commercial buildings, archives, museums, libraries, etc. must be respected.

purpose

Control of temperature and humidity regimens of buildings.

Tasks

  • Creating a full-fledged automated temperature monitoring system and humidity in the building
  • Displaying parameters with reference to the real building layout
  • Ensuring the possibility of expanding the system to a full-scale ASU of the life support systems of the building.

Functions

  • Collection and processing of operational information from temperature and humidity sensors
  • Displays operational information in the form of mnemoshem, trends (graphs) on AWP monitors with the delimitation of user access rights
  • Registration of system events
  • Installing settings (emergency and preventive boundaries) temperature and humidity for each sensor in real time
  • Survey control of each sensor in real time
  • Notification of disorders (technological alarm)
  • Diagnosis of the accuracy of the information taken
  • Archiving the history of parameters.

Architecture

The automated temperature monitoring system and humidity in the building is represented by three hierarchical levels.

The first (lower) level includes temperature and humidity sensors (thermohygrometers) C2000-W (Production of a company of a car).

The second (medium) level is represented by the C2000-KDL-MODBUS controller (manufactured by the company of the company). Support is implemented up to 63 temperature and humidity sensors in terms of connecting to one controller. All algorithms are ready and require only settings.

The third (top) level includes an automated workplace (ARMS) Operator based on SCADA Circle-2000 Combined with archiving server functions.

The temperature and humidity values \u200b\u200bfrom the sensors go to the controller pass the primary processing and then on the RS485 digital interface (MODBus protocol) are transmitted to the operator's arms in order to display them, further processing and storage.

Features

C2000-KDL-MODBUS controller (manufacturer - company car):

  • designed for use in systems for controlling the temperature and humidity regime of the building, security and fire systems, fire protection systems (alerts, smoke removal, firecuts and other executive devices)
  • it has the ability to indicate on the built-in light indicators (the controller state, the status of exchange for DPLS and the RS-485 interface)
  • supports exchange according to the standard Modbus software protocol
  • provides easy and convenient software configuration
  • production in Russia.

SCADA Circle 2000 ® (NPF "Circle") - a universal software product designed to create automation systems of technological objects in many industries and possessing the following features:

  • the reliability of SCADA is confirmed by numerous implementation in many industries, including on highly dangerous industries of energy, oil and gas industry.
  • availability of ready-made projects and templates for the implementation of ventilation systems, as well as full-scale ACS buildings and structures
  • mODULANTY OF CONSTRUCTION AND SCALATION Allow to step up and expand the system to a full-scale ASU of the life support of the building
  • openness and support of international standards, specifications and exchange protocols make it possible to integrate with most of the instruments of third-party manufacturers
  • powerful and at the same time intuitive tools for the development of user projects allow the customer to make changes in systems on their own, without attracting contracting organizations.
  • Scada Circle 2000 is included in the Unified Register of Russian Programs, is a 100% import-substituting product.

Benefits

  • Timely provision of high-quality information about the temperature-humiductural mode of the building with reference to the real layout of the building
  • Ensuring the possibility of scaling and increasing the functionality of the system, including the customer forces
  • The possibility of expanding the temperature monitoring system and humidity to a full-scale ASU of the life support of the building
  • Minimizing the cost of executing engineering works by the Customer - only the project setting is required.
  • Long-term storage of data
  • The optimal ratio of the "price-quality" system.