Fire detector thermal IP 101 1A A1. Purpose and scope

Fire detector Thermal Maximum IP 101-1A-A3 is needed to work in a complex fire alarm system and fire extinguishing. Its continuous work provides a high level of fire protection. With increased response temperature: + 64 ° C ... + 76 ° C

Fire detector thermal maximum IP101-1A-A3:

Additional devices in the Security and Fire Alarm of the IP series have stable characteristics, and refer to the "Universal Auxiliary Instruments" category.

  • Round-the-clock operation;
  • Is an integral part of complex fire protection;
  • Connects to control devices that have powered or alternating current;
  • Any polarity when connected;
  • The smoke detector is triggered when a certain ambient temperature is reached.

A wide range of devices allows you to make a choice of model for any request and functionality. A large selection will delight companies engaged in the installation of fire and security alarm systems and their customers.

Specifications IP 101-1A-A3

Name of parameter The value of the parameter
Type of detector

2-wired

Treatment temperature + 64 ° C ... + 76 ° C
Light indication "Duty mode"; "Fire"
Power supply voltage for signaling 10 - 25 V
Current consumption in standby mode 0.06 Ma
Dimensions (diameter / height) 62/34 mm
Degree of protection IP30.
Operating temperature range -10 ° C ... + 76 ° C
Weight 0.02 kg
Equipment:
  • Detector IP 101-1A-A3 (IP 101-1A-A3)
  • Passport Sapo.425212.004ps.
  • Alarm for office;
  • Fire alarm for cafes and clubs;
  • Alarm to the store;
  • Fire systems for warehouse and office premises;
  • Autonomous fire alarm for apartment, house or cottage;
  • Fire alarm for indoor car parks, garages and parking;
  • Complex fire protection for government agencies (kindergartens, schools, other educational institutions)

Special attention when choosing, take a careful study of the technical characteristics, choosing suitable security detectors, fire detectors, special cable products. Instruments line IP are some of the best By the ratio of price-quality and recommended for use in the system of security and fire alarm systems of a large spectrum.

Analogs of IP 101-1A-A3 and other Instruments similar to characteristics:

Buy and order delivery of fire alarm systems in Moscow:

Fire detector Thermal Maximum IP101-1A-A3, as well as other products (their analogues, detectors, control devices) You can order and buy through the online store of the fire alarm of our site or order delivery and custom installation services in your premises in Moscow in Moscow ABARS company. (Attention, delivery is free when ordering over 60 thousand rubles).

IP101-1A-A1 Thermal 54 ° C detector, with the indicator and detector of the IP101-1A-A3, serve to detect signs of fire (increase in the temperature of the medium). Anxiety notice is formed when the ambient temperature reaches the threshold value. The detectors are designed for round-the-clock work in closed heated rooms and are designed for joint operation with receiving and control devices with constant or alternate currents.

Features IP101-1A-A1

  • Microprocessor analysis of the temperature sensor signal.
  • The detector periodically measures the ambient temperature and when the threshold temperature reaches the temperature value produces alarming notification by increasing the current consumed.
  • For ease of operation, there is a red LED indicator. In standby mode, the indicator gives brief flashes with an interval of 6 ... 8 s. In anxious mode, the LED indicator in the detectors of the IP101-1A-A1 and IP101-1A-A3 gives the double and triple flashes with a frequency of 1 Hz, respectively. This makes it easy to detect a detector that has worked.
  • Detectors are powered directly through the signaling loop, thereby disappears in the additional wires of the power line.
  • The detector design ensures their connection to the signaling loop without compliance with polarity.
  • The possibility of connecting to fire loops of devices of receiving-control security and fire fighters "granite", "Karat", Wats-1-1a, "Quartz" without using external restrictive resistors.
  • The aesthetic design of the detector enclosures fits into the interior of any premises.

IP101-1A-A1 Thermal 54 ° C detector, with the indicator and detector of the IP101-1A-A3, serve to detect signs of fire (increase in the temperature of the medium). Anxiety notice is formed when the ambient temperature reaches the threshold value. The detectors are designed for round-the-clock operation in closed heated rooms and are designed for joint operation with receiving-control devices with loops of permanent or alternate current. SP101-1A-A1 microprocessor analysis of the temperature sensor signal. The detector periodically measures the ambient temperature and when the threshold temperature reaches the temperature value produces alarming notification by increasing the current consumed. For ease of operation, there is a red LED indicator. In standby mode, the indicator gives brief flashes with an interval of 6 ... 8 s. In anxious mode, the LED indicator in the detectors of the IP101-1A-A1 and IP101-1A-A3 gives the double and triple flashes with a frequency of 1 Hz, respectively. This makes it easy to detect a detector that has worked. Detectors are powered directly through the signaling loop, thereby disappears in the additional wires of the power line. The detector design ensures their connection to the signaling loop without compliance with polarity. The possibility of connecting to fire loops of devices of receiving-control security and fire fighters "granite", "Karat", Wats-1-1a, "Quartz" without using external restrictive resistors. The aesthetic design of the detector enclosures fits into the interior of any premises. Heat fire detectors

Any room - office, shop, apartment or warehouse, is constantly at risk of fire in it. Its reason can be anything - closing electrical wiring, malfunction of electrical appliances, self-burning material or human factor. To any owner of the property, I want to save your property from destruction. For organizations of a certain kind of activity, the presence of a fire alarm is a prerequisite for opening an enterprise and work. There is a completely natural question: how to equip the fire alarm at the facility inexpensively, reliable and in accordance with the existing requirements. The answer to such a question may be setting the detector of the IP 101-1A. This device combines reliability, simplicity and price availability.

Purpose and scope

Fire detectors IP 101-1A-A3 and IP 101-1A-A1 are intended to identify signs of fire in heated warm rooms. The flow of alarm signal occurs when the temperature of the threshold specified by the sensor is raised. Detectors have round-the-clock operation. Presentable appearance (small white plastic cylinder) makes it possible to install them in the highest status premises.

Detectors work together with other control sensors in the fire alarm system. Their design provides for the possibility of connecting to any DC loop.

Thermal detectors IP 101 1A can be mounted in such premises:

  • in warehouses and repositories of various purposes;
  • in offices and government agencies;
  • in the governing staff;
  • in banks and post offices;
  • in cafe, shops and stalls;
  • in apartments and garages.

The devices work only on heat, without reacting to light sources, smoke or gas.

Device and principle of operation

IP 101 1A detector is a compact device that has a pretty simple, but functional device

It consists of the following details:

  1. Case. The housing consists of a base and a cover with air holes. The base is equipped with terminals for connecting the instrument to the signaling loop.
  2. The electronic unit. It has a light indicator, a heat sensitive element, an electronic locking key and an electrical diode scheme.

Space scanning is carried out automatically by periodic direction of pulses to the thermoelement. When the control temperature reaches the resulting pulse causes a closure in the chain, the signal from which enters the control instrument. The LED at the same time glows continuously, pointing the location of the shown sensor.

Features of the device

Thermal detectors of the IP 101 series are beneficial from the thermal sensors of other structures. They do not have fusible compounds and bimetallic petals that do not differ high reliability and often give false signals.

In addition, these instruments possess the following features:

  • the signal from the temperature sensor is analyzed by a microprocessor;
  • the alarm feed is carried out by changing the electrical parameters;
  • the presence of a light indicator that submits the corresponding signal to the operating mode;
  • active analysis of air temperature indoors;
  • power supply directly through the loop;
  • lack of the need for polar connection;
  • adaptation to electrical parameters of control and receiving devices of fire systems.

The design of the cover allows aesthetically and harmoniously placing the device in various rooms.

Advantages and disadvantages

As with any technical product, thermal detectors have their pros and cons.

The advantages of the product include such indicators:

  • high speed check of temperature condition (every 6 seconds);
  • accuracy of shuttering threshold by measuring current force;
  • lack of unreliable mechanical relays;
  • there is no need to install a separate power line;
  • lack of polarity connection;
  • no device resistance adjustment is required when connecting to security systems;
  • quick return to the duty mode after the trigger;
  • low weight and size, which allows you to place the device on thin bases without mortgage parts;
  • affordable price (today - within 150-225 rubles).

The disadvantages of this series include such:

  • detectors cannot work in the cold;
  • the chemically active environment is an obstacle to the installation of sensors;
  • there is no possibility of using a detector in GSM systems.

Despite minor disadvantages, IP 101 detectors enjoy well-deserved popularity and demand.

Main technical characteristics

The IP 101 1A detector has such technical characteristics to pay attention to potential buyers:

  • weight - 90-100 grams;
  • size - 60-65 × 25-30 mm;
  • supply voltage - 10-25 V;
  • operating temperature - from 0 ° C to + 76 ° C;
  • response temperature - + 70 ° С (± 6 ° C);
  • response time - 90-600 seconds (depending on the rate of increasing temperature);
  • coating area - 25 m;
  • return to standby mode after shutdown - 2 sec;
  • relative humidity of air indoor - up to 95%;
  • the average service life is 10 years.

The manufacturer gives a warranty on the detector within 36 months after installation.

Installation of thermal detectors

The devices can be installed simultaneously with other control sensors, as well as after they are installed. The number of declared detectors depends on the technical capabilities of the security system.

The fastening of the devices is carried out to the ceiling, since when fireing in this place is the highest temperature.

On a note: The sensor from the sensor is set at a distance of no more than 5 m throughout the ceiling area.

Mount the detectors can be on any material. It can be concrete, wood, drywall or plastic. For soft materials, wood screws are used for solid - plastic dowels and self-tapping screws.

After connecting the wires, the base base is fixed on the ceiling and the closure of the lid. Connecting devices in the chain is carried out in parallel.

Maintenance of devices is carried out quarterly and includes such actions:

  1. External inspection for the detection of mechanical damage on the sensor housing and loop line.
  2. Check the reliability of the sensor fastening on the base.
  3. Cleaning the device from dust and dirt. Attention should be paid to cleaning the gratings through which the air enters the sensor.
  4. Check the strength of the connection of wires on terminals.
  5. Check device performance.

When a malfunction detects, the device is sent to the manufacturer's factory with the corresponding explanations, and a new detector is connected to its place.

Video about fire sensor IP 101-1A

Features:
Electronic control circuit.
The detector periodically measures the ambient temperature and when the threshold temperature is reached, the temperature range produces an alarming notification by closing the alarm loop.
For the convenience of controlling the operation of the detector, there is a red LED indicator. In standby mode, the indicator gives brief flashes with an interval of 8 s. In the alarm mode, the indicator glows constantly, which makes it possible to easily detect the detector worked.
The detector is powered directly through the alarm loop, which disappears the need for additional wires of the power line.

Polarity of the supply voltage

arbitrary

Power supply loop

10 ... 25 V

Average consumption current in standby mode, no more

0.05 Ma

A permissible current closure current in anxious mode, no more

20a

Residual closed loop voltage no more

4.5 V.

Rated temperature of response

70 ± 6 ° С

Interval between temperature measurements

8 S.

Return time to the duty mode after removing the supply voltage, not more than

5 S.

Protected surface, not less

25 sq.m.

Operating temperature range

0 ... + 55 ° С

Mass, no more

100 g

Shell protection shell

IP30.

Service life, not less

10 years

The fire detector Thermal Maximum IP101-1A complies with the requirements of the NPB 76-98 and is designed to issue a signal into the fire alarm cable (IPS) by closing the loop when the ambient temperature of the threshold value is reached.

The detector is designed for continuous round-the-clock work in closed heated rooms.

The detector is designed to work together with the receiving and control devices (PCP), which perceive the closure signal (SPS) and having a constant or alternate current loop.

The detector is not intended for use in chemically aggressive environments.

Execution of the detector - ordinary according to GOST 12997-84.
The type of climatic version - Uhl category 3.1 according to GOST 15150-69 to work in the temperature range from 0c to + 50c and relative air humidity up to 95% at a temperature of + 35c.

The nominal value of the transition temperature of the detector + 70s. The deviation of the detector's response from the nominal value is not more than 5%.

The inertia of the detector's response (the temperature of the medium temperature from + 25c until the detector is triggered) at a rate of temperature of 30c / min located within 39 ... 162 sec. The inertia of the detector's response at the rate of increase of 3c / min is within 433 ... 1120 sec.

The detector power supply is carried out on the SPS directly from the PCP. Range of supply voltages from 10 to 25 V.

Current consumed in standby mode no more than 50 μA.

The protected surface of at least 25 sq.m. Indication of duty and alarm modes.

Electronic control circuit. The detector periodically measures the ambient temperature and when the threshold temperature reaches the temperature value produces alarming notification.
For the convenience of controlling the operation of the detector, there is a red LED indicator.
In standby mode, the indicator gives brief flashes with an interval of 8 s. In the alarm mode, the indicator glows constantly, which makes it possible to easily detect the detector worked. The detector is powered directly through the alarm loop, which disappears the need for additional wires of the power line.
The design of the detector is ensured its connection to the signaling loop without compliance with polarity.
Aesthetic design of the detector enclosure fits into the interior of any premises.

PASSPORT

Firefighter thermal detectors Maximum IP 101-1A-A1, IP1 01-1A-A3 (hereinafter referred to as detectors) are designed to work as part of the automatic
fire extinguishing and fire alarm installations. At the temperature and time of response, the detectors of the IP 101-1A-A1 and IP 101-1A-A3 are respectively to the Classes A1 and A3 of the NPB 85-2000. Detectors are designed for continuous round-the-clock operation in closed heated rooms together with receiving and control devices that have a fire alarm cable (SPS) of a constant or alternating current. The polarity of the detector connection to the IPS can be arbitrary. Detectors give out the "Fire" signal into the signaling loop by increasing the current consumption when the ambient temperature is exceeded
air installed threshold. The detector has a LED indication of the duty mode and the fire mode.
The detector implements a microprocessor analysis of the temperature sensor signal, allowing to achieve high accuracy and small inertia
triggering in the entire range of temperature rates of temperature. In the detector, it is possible to connect to the instrument supplies
receiving-control security and firefighters (ppkop) "Granite", "Karat", Wats-1-1a, "Quartz" without using external restrictive resistors. The external resistor connected to the additional contact of the terminal connector can be used to include in the SPS of other PPKOP.
The detector is not intended for use in chemically aggressive environments. Execution of the detector - ordinary according to GOST 12997-84 for work in
the temperature range from minus 10 s to + 76 s and relative humidity to 93% at a temperature of + 40 C. Degree of protection of the shell detector
iP30 according to GOST 14254-96.

Device and principle of operation
Constructive detectors are made in a plastic case, consisting of a base and a decorative protective cover with protruding grid compartment. Based on three screw terminals for connecting a detector to the SPS line and installation, if necessary, additional cutting
stora. At the edges of the decorative lid there are two mounting holes for mounting the detector on the protected object.
In standby mode, the temperature of the external environment is measured by the detector discretely, for short time intervals following the 6 ... 8
seconds. Each measurement is accompanied by a short flash of the red LED indicator.
Upon reaching the threshold temperature value of the medium, the detector goes into the "Fire" mode. In this mode, the residual voltage (between terminals 1 and 2) at a current of up to 20 mA does not exceed 8.5 V. LED indicator in the detectors of IP 101-1A-A1 and IP 101-1A-A3 gives respectively dual and triple flashes with a frequency 1 Hz.
Detectors retain the state of "fire" after exposure
increased temperature. Transition of the detector to duty mode