Split systems error codes. Error codes for all brands of air conditioners and split systems Cassette air conditioner gree error e6

Aeronik error codes

Error codes for air conditioners Aeronik

E1 - the pressure in the discharge of the compressor has increased;
E2 - the heat exchanger froze indoor unit;
E3 - the pressure in the compressor discharge has decreased;
E4 - the temperature of the discharge pipeline has increased;
E5 - actuation of the compressor current relay;
F0 - there was a malfunction in the temperature sensor of the air inside
premises, in a heat exchanger in an indoor unit or ambient air in an outdoor unit;
F0 - There may also be a freon leak in the indoor unit.
E6 - there are faults in the commutation;
E8 - the internal block motor is overloaded;
F1 - there are malfunctions in the temperature sensor in the heat exchanger;
F4 - there are malfunctions in the temperature sensor of the discharged in
room air.
H1- is not an error. the air conditioner has switched to auto defrosting mode.

Airwell error codes

Airwell air conditioner error codes



Akvilon error codes

Akvilon air conditioner error codes

Possible mistakes

Monitor mode 1

(Indicator on

display)

Monitor mode 2

(Wire controller)

Appearance order

Actions

Communication error

Completion of work

Drainage system error

Indicator lights up 4 times / 8sec

Completion of work

Phase loss, phase failure or low voltage error

Indicator lights up 6 times / 8s

Completion of work

The indicator lights up 1 time / 8sec

Completion of work

Indoor unit sensor anomaly (TE)

The indicator lights up 2 times / 8s

Completion of work

Indicator lights up 2 times / 1sec

Continue to work

Internal overheating protection

Completion of work

Defrosting (not error)

The operation indicator lights up

Continue to work

Fault codes for a 380-415W power supply

Suitable for 36000 ~ 60000BTU units, with power supply 380-415W 3N, 50Hz

Possible mistakes

Display mode 1

(Indicator on panel

display)

Display Mode 2

(indicator

errors on the control panel)

Display Mode 3

(controller

wires)

Appearance order

Actions

Communication error

Lights up 5 times and goes out after 2 seconds

Completion of work

Communication error with wire controller

Completion of work

Error drainage system

Lights up 4 times and goes out after 2 seconds

Completion of work

External protection (Phase loss)

Lights up 6 times and goes out after 2 seconds

Completion of work

External protection (overheating discharge)

Lights up 10 times and goes out after 2 seconds

Completion of work

Defence from high pressure

Completion of work

Low pressure protection

Lights up 9 times and goes out after 2 seconds

Completion of work

Room temperature sensor anomaly (Air temperature)

Lights up 1 time and goes out after 2 seconds

Completion of work

Indoor unit sensor anomaly (TE)

Lights up 3 times and goes out after 2 seconds

Completion of work

Outdoor unit sensor anomaly (TW)

Lights up 2 times and goes out after 2 seconds

Lights up 2 times and goes out after 2 seconds

Continue to work

Anomaly external sensor condensate temperature (TL)

Lights up 7 times and goes out after 2 seconds

Continue to work

Temperature sensor (TP) discharge anomaly

Lights up 8 times and goes out after 2 seconds

Continue to work

Ballu error codes

Ballu air conditioner error codes


E1 - short circuit or open circuit of the sensor responsible for the indoor unit.
E2 - short circuit or open circuit of the sensor responsible for the condenser temperature.
E3 - short circuit or open circuit of the sensor responsible for the evaporator temperature.
E4 - short circuit or open circuit of the sensor responsible for the indoor unit.
E6 - the protection of the outdoor unit has been triggered.
E8 - the electrostatic filter is clogged.
P4 - an error has occurred in the operation of the evaporator sensor due to a high or
low temperature.
P5 - an error has occurred in the operation of the condenser sensor due to a high or
low temperature.
P6 - there was a defrosting mode activation or a delay in operation
heat exchanger.

Carrier error codes

Carrier air conditioner error codes


2 - there is a malfunction of the temperature sensor in the room;
3 - there was a malfunction of the temperature sensor in the internal
heat exchanger;
6 - there are malfunctions in the operation of the reversing valve in the outdoor unit;
8 - there were malfunctions in the fan motor located in
indoor unit;
9 - there is no electrical power supply to the indoor unit;
11 - there are malfunctions in the drainage pump;
12 - there was a software failure in the indoor unit;
13 - an error occurred in the configuration;
14 - signal is lost in the central control system;
15 - there was a malfunction of the temperature sensor in the internal
heat exchanger;
18 - there are malfunctions in the outdoor unit control;
20 - block position is not recognized;
21 - malfunctions of the current sensor located in the outdoor unit;
22 - there was a malfunction of the temperature sensor in the outdoor
heat exchanger;
23 - there were malfunctions of the discharge temperature sensor;
24 - there are malfunctions in the operation of the fan in the outdoor unit;
26 - other malfunctions in the outdoor unit;
27 - there was a blockage of the compressor located in the outdoor unit;
28 - the value of the discharge temperature is unacceptable;
29 - there are malfunctions in the compressor, located in the outdoor unit;
31 - there was an increase in pressure in the circuit of the outdoor unit.

Cooper & Hunter Error Codes

Cooper & Hunter air conditioner error codes

Code E0 - exceeding the lower threshold of the starting voltage. Frequency controller start-up.
E1 code - overpressure. Compressor protection system starts.
Code E2 - the threat of freezing of the indoor unit. Launching the protection system.
Code E3 - lowering the permissible pressure threshold. Compressor protection system starts.
E4 code - excess permissible temperature injection tube. Launching the protection system.
Code E5 - compressor overload. Launching the protection system.
Code E6 - error in connection / operation of the signal or power cable.
Code E7 - the set modes of the split system do not match.
Code E8 - evaporator overheating. Launching the protection system.
Code E9 - start of the cold air protection system in thermal mode.
Code F0 - breakdown of the temperature discharge sensor.
Code F1 - breakdown of the evaporator temperature sensor.
Code F2 - breakdown of the condenser temperature sensor.
Code F3 - breakdown of the air temperature sensor in the system.
Code F4 - breakdown of the blower temperature sensor.
Code F5 - breakdown of the compressor discharge tube sensor.
Code F6 - condenser overheating.
Code F7 - there is not enough lubrication in the compressor crankcase.
F8 code - compressor overloaded. Launching the protection system.
Code F9 - exceeding the maximum condenser temperature due to a decrease in fan speed during cooling. The compressor is overloaded.
FF code - there is no power supply to one of the phases / error in the operation of the phase monitor.
FA Code - Condenser / Evaporator Overheating. Launching the protection system.
FH code - evaporator freezing threat. Launching the protection system.
Code H0 - overheating protection activated.
H1 code - condenser defrosting mode is activated.
Code H2 - error in the electrostatic filter. Launching the protection system.
Code H3 - exceeding the permissible compressor temperature. Launching the protection system.
H4 code is an error in the system.
Code H5 - start of the protection system of the inverter unit IPM.
Code H6 - sensor malfunction. Feedback signal from fan motor lost.
Code H7 - compressor defective.
Code H8 - the drainage system is full. Launch protection.
Code H9 - malfunction electric heater indoor unit.

Daikin error codes

Daikin air conditioner error codes


A0 - activation of the protective device.
A1 - PCB problems.
A2 - fan motor is blocked.
A3 - abnormal drainage level.
A4 - malfunctions in the heat exchanger.
A5 - abnormal temperature in the heat exchanger.
A6 - fan motor is overloaded.
A7 - the blinds drive is faulty.
A8 - current overload of the device.
A9 - the expansion valve is defective.
AA - engine overheated.
AH - dirty air filter.
AC - fixed idle.
AJ - Insufficient Performance.
AE - poor water supply.
AF - a defect in the humidifier has been detected.
C0 - sensor is faulty.
C3 - the sensor responsible for the drainage system is faulty.
C4 - the sensor responsible for the temperature of the heat exchanger 1 is faulty.
C5 - the sensor responsible for the temperature of the heat exchanger 2 is faulty.
C6 - fan motor is overloaded.
C7 - the sensor responsible for the blind drive is defective.
C8 - the sensor responsible for the input current is faulty.
C9 - defective inlet air thermistor.
CA - Outlet air thermistor defective.
CH - high level of pollution.
CC - the humidity sensor is defective.
CJ - the temperature sensor located on the control panel is faulty.
CE - the radiation sensor is faulty.
CF - the sensor responsible for high pressure is faulty.

Error codes of the outdoor unit of Daikin air conditioners (Daikin)

E0 - a protective device has been triggered.
E1 - the printed circuit board located in the outdoor unit is faulty.
E3 - triggering of the sensor responsible for high pressure.
E4 - actuation of the sensor responsible for low pressure.
E5 - overheating relay or compressor motor is overloaded.
E6 - the compressor motor is blocked.
E7 - the fan motor is blocked.
E8 - current overload is fixed.
E9 - the expansion valve is faulty.
AH - the pump has been blocked.
EJ - activation of an additional protective device.
EE - the permissible water level has been exceeded in the drainage system.
EF - the unit responsible for heat storage is defective.
H0 - general sensor malfunction.
H1 - the sensor responsible for the air temperature is faulty.
H2 - the sensor responsible for the electrical power supply is faulty.
H3 - the sensor responsible for high pressure is faulty.
H4 - the sensor responsible for low pressure is faulty.
H5 - activation of the overload sensor or the compressor does not work.
H6 - activation of the blocking sensor or the compressor is overloaded.
H7 - activation of the blocking sensor or the fan is overloaded.
H8 - triggering of the sensor responsible for the input voltage.
H9 - activation of the sensor responsible for the outdoor temperature.
HА - actuation of the sensor responsible for the outlet air.
HH - triggering of the sensor responsible for blocking the water pump.
HС - triggering of the sensor responsible for hot water.
HЕ - actuation of the sensor responsible for the drainage system.
HF - an accident has occurred in the heat storage unit.
F0 - actuation of devices # 1 and # 2, which are responsible for protection.
F1 - actuation of device # 1, which is responsible for protection.
F2 - actuation of device # 2, which is responsible for protection.
F3 - the temperature in the discharge pipe is too high.

Dantex error codes

Error codes for Dantex air conditioners (Dantex)


E1 - an error occurred in the non-volatile memory;
E2 - a zero crossing error occurred;
E3 - there is no control of the rotation speed of the indoor unit fan;
E4 - the protection mode against increased level voltage;
E5 - there is no contact with the control of an open temperature sensor;
E6 - there is no contact with the control of the evaporator temperature sensor.

Chillers Dantex (DN)

E0 - an error occurred in the operation of the water flow meter;
E1 - an error occurred while connecting the phases;
E2 - a communication error has occurred;
E3 - an error occurred in the outlet water temperature sensor;
E4 - an error occurred in the temperature sensor of the water at the outlet from
shell-and-tube heat exchanger;
E5 - error in the operation of capacitor A;
E6 - an error in the operation of the capacitor B;

E8 - an error occurred in the discharge air temperature sensor;
E9 - an error occurred in the flow meter;
EA - the main block revealed a decrease in the number of additional blocks;
EB - malfunctions of the frost protection system;
EC - malfunctions of the drive controller;
ED - an error occurred in the control system and communication between the units;
Ed - electrical protection actuation;
EE - there was an error in communication between the microprocessor and the control panel;
ЕF - an error occurred in the inlet water temperature sensor;
RO - overheating or increased pressure;

P2 - the pressure has increased or the air in system B has overheated;
P3 - the pressure in the system has decreased;
P4 - there was an overcurrent in system A;
P5 - there was an overcurrent in system B;
P6 - the pressure in the condenser of system A has increased;
P7 - the pressure in the condenser of system B has increased;
P8 - malfunctions of the compressor discharge temperature sensor in system A;
Pb - frost protection;
PE - the temperature in the heat exchanger has decreased;
F1 - errors in the read-only memory;
F2 - errors in the operation of wired controllers.

Elektrolux error codes

Error codes for air conditioners Elektrolux (Electrolux)


E1 - the pressure level is exceeded;
E2 - the indoor unit froze;
E3 - the pressure level is too low;
E4 - compressor malfunctions;
E5 - overcurrent has occurred;
E6 - there is no connection between the indoor and outdoor units;
E7 - there was a conflict in the operating modes of indoor units;
E8 - the fan of the indoor unit is overloaded;
E9 - the drainage bath is overflowing;
F0 - malfunctions of the temperature sensor in the indoor unit;
F1 - malfunctions in the temperature sensor inlet to the heat exchanger
in the indoor unit;
F2 - malfunctions in the temperature sensor in the middle

F3 - malfunctions in the temperature sensor at the exit from
heat exchanger in the indoor unit;
F4 - malfunctions in the ambient air temperature sensor;
F5 - malfunctions in the outdoor unit temperature sensor;
F6 - malfunctions of the temperature sensor inlet to the heat exchanger
in the outdoor unit;
F7 - malfunctions in the temperature sensor output from
heat exchanger in the indoor unit;
F8 - malfunctions in the first discharge temperature sensor
compressor;
F9 - malfunctions in the second discharge temperature sensor
compressor;
FA - malfunctions in the operation of the crankcase temperature sensor of the 1st compressor;
FB - malfunctions in the operation of the crankcase temperature sensor of the 2nd compressor;
FC - malfunctions in the high pressure sensor;
FD - malfunctions of the low pressure sensor;
ЕН - malfunctions in the operation of the additional heater.

Fuji error codes

Fuji air conditioner error codes


E00 - an error occurred in connection with the remote control with the indoor unit;
E01 - an error occurred in communication between the indoor and outdoor units;
E02 - malfunctions of the room temperature sensor;
E03 - a short circuit has occurred on the room temperature sensor;
E04 - an error occurred in the operation of the temperature sensor on the internal
heat exchanger;
E05 - a short circuit has occurred on the internal temperature sensor
heat exchanger;
E06 - an error occurred in the operation of the temperature sensor on the outside
heat exchanger;
E07 - a short circuit has occurred on the outdoor temperature sensor
heat exchanger;
E08 - the supply of electrical energy is interrupted;
E09 - there was an overflow of the tank intended for collecting condensate;
E0R - malfunctions of the outdoor unit temperature sensor;
E0B - a short circuit has occurred on the outdoor unit temperature sensor;
E0C - opening of the temperature sensor on the drain pipe is required;
E0D - a short circuit has occurred on the temperature sensor of the drain pipe;
E0F - the outlet temperature is too high or too low;
E11 - malfunctions of the control board;
E12 - malfunctions of the indoor unit fan;
E13 - giving by the system incorrect signals;
E14 - error in non-volatile memory.

General Climate error codes

General Climate air conditioner error codes


E2 - short circuit or open circuit of the sensor responsible for the temperature of the internal
air.
E3 - short circuit or open circuit of the sensor responsible for the evaporator temperature.
E4 - short circuit or open circuit of the sensor responsible for the condenser temperature.
E5 - in progress drain pump An error has occurred.
E6 - error in protecting the external unit.
E7 - An EEPROM error has occurred.
E8 - the overflow protection of the drain pan has been triggered.

Gree error codes

Gree air conditioner error codes


E1 - the compressor protection against too high pressure has been triggered.
E2 - frost protection of the indoor unit has been triggered.
E3 - compressor protection against too low pressure has been triggered.
E4 - the high temperature protection of the discharge tube has been triggered.
E5 - overload protection of the system or compressor has been triggered.
E6 - problems were detected in the signal or power cables.
E7 - contradictions in the established mode.
E8 - protection of the electric motor or evaporator from overheating has been triggered.
E9 - protection against cold air intake during heating has been triggered.
E0 - protection of the frequency regulator from too low starting
voltage.
H6 - there is no feedback signal from the fan motor.
F0 - the temperature discharge sensor is faulty.
F1 - the sensor responsible for the evaporator temperature is faulty.
F2 - the sensor responsible for the condenser temperature is faulty.
F3 - the sensor responsible for the air temperature in the system is faulty.
F4 - the sensor responsible for the temperature of the supercharger is faulty.
F5 - the sensor responsible for the compressor discharge pipe is faulty.
F6 - capacitor overheating detected.
F7 - oil carryover from the compressor is fixed.
F8 - overload protection of the system or compressor has been triggered.
F9 - compressor protection against high temperatures has been triggered.
FF - there is no power in one of the phases or the phase monitor is faulty.
H1 - defrosting is in progress.
H2 - protection of the electrostatic filter has been triggered.
H3 - protection against severe overheating has been triggered.
H4 - a system failure has occurred.
H5 - activation of the protection of the IPM block.
H7 - compressor malfunction.
H8 - actuation of overflow protection of the drainage system.
H9 - electrical heater malfunction.
H0 - activation of overheating protection.
FA - overheating protection of the condenser or evaporator.
FH - operation of the evaporator frost protection.

Green error codes

Green conditioner error codes


U1 - Current phase fault, circuit detection for compressor. Flashes 13 times. During cooling and drying operation, the compressor will stop while the internal fan is running. During heating operation, the complete unit will stop. Replacing the external control panel AP1.

U3 - Fault voltage dropping on the DC bus. Flashes 20 times. During cooling and drying operation, the compressor will stop while the internal fan is running; When operating in heating mode, the complete unit will stop.
The supply voltage is unstable.

U5 - Fault full unit current detection. Flashes 13 times. During cooling and drying action, the compressor is stopped while the internal fan is running; During heating operation, the complete unit will stop the operation. There is a circuit malfunction on the outdoor units AP1 control panel, please replace the outdoor unit AP1 control panel.

U7 - Blinks 20 times. If this malfunction occurs during heating operation, the device will stop working. 1. The supply voltage is lower than AC175V; 2.Wiring terminal 4V is loose or broken; 3.4V will be damaged, please replace the cable.

U8 - Zero transition inspection malfun-fiction diagram Fan motor pin. Flashes 17 times every 3s Remote controller operation or
the control panel is available, but the unit will not function. The discharge rate of the capacitor is slow, which lead wrong decision controller. Zero crossing detection circuit of the main board abnorma. Refer to flowchar repair.

U9 - Zero crossing fault outdoor unit... Flashes 18 times. During the cooling operation, the compressor will stop while the internal fan will run; during heating, the device will not work. Replacing the external control panel AP1.

Haier error codes

Haier air conditioner error codes (Haer)

E0 Violation of the condensate drain function.
E1 Compressor is pressurized.
E2 The heat exchanger of the indoor unit is covered with ice.
E3 Insufficient pressure in the compressor.
E4 Compressor overheating.
E5 Compressor off due to increased load.
E6 No communication between blocks.
E7 The indoor unit does not respond to commands from the keypad.
E8 Indoor unit motor overload.
F0 The room temperature sensor has disconnected.
F1 The temperature sensor of the indoor unit heat exchanger has disconnected.
F2 The temperature sensor of the heat exchanger of the outdoor unit has disconnected.
F3 The outdoor temperature sensor has disconnected.
F4 The temperature sensor on the air supply has disconnected.
FF Power supply interrupted.

Hisense error codes

Hisense air conditioner error codes

Possible causes of the malfunction:
1 Outdoor heat exchanger temperature sensor error a. The outdoor unit heat exchanger temperature sensor circuit is open; b. The temperature sensor of the heat exchanger of the outdoor unit is faulty; With. Defective outdoor unit control PCB
2 Compressor discharge temperature sensor error a. Open circuit of the temperature sensor in the compressor discharge line; b. The temperature sensor in the compressor discharge line is faulty; With. Defective outdoor unit control PCB
5 Integral Power Module (IPM) protection tripped a. Defective Integrated Power Module (IPM) circuit board; b. The fan of the outdoor unit is out of order; c. The fan motor of the outdoor unit is defective; d. The outdoor fan is blocked; e. The condenser is dirty; f. The rules for installing the outdoor unit have not been followed.
6 Tripping of an overvoltage or undervoltage protection device in the AC mains a. The voltage in the network is above or below the maximum permissible values; b. The supply voltage of the unit is higher or lower than the maximum permissible values
7 Communication error between indoor and outdoor units a. Broken connection cable; b. The connecting cable is damaged; With. Incorrect connection or broken connection between the filter board and printed circuit board outdoor unit control
8 Overload protection device a. Fan motor malfunction; b. The evaporator and condenser are dirty; c. Air intake and air outlet blocked; d. The printed circuit board of the outdoor unit is faulty; e. Defective compressor
10 Communication error between two microcircuits (control and drive) in printed a. Poor cable connection b. Defective outdoor PCB or drive circuit board;
11 Outdoor unit EEPROM memory error a. Poor soldering of the EEPROM microcircuit; b. EEPROM chip installation error (wrong position); .EEPROM chip defective
12 Tripping of the protective device when low temperatures outside air a. This protection is triggered if the outdoor temperature drops below 15 ° C; b. Outdoor temperature sensor defective; With. The control PCB of the outdoor unit is defective.
13 Protection device tripped due to increased temperature in a. The temperature sensor in the compressor discharge line is faulty; b. Insufficient refrigerant charge in the system
14 Outdoor temperature sensor error a. The outdoor air temperature sensor circuit is open; b. Outdoor temperature sensor defective; With. Defective outdoor unit control PCB
15 Compressor thermal overheat protection tripped a. Compressor discharge temperature sensor open circuit b. Insufficient refrigerant charge in the system
16 Activation of the heat exchanger frost or overload protection device when the indoor unit is operating in heating mode a. Normal operation of the protection device when the heat exchanger freezes or overloads; b. Open circuit of the temperature sensor of the heat exchanger of the indoor unit; c. The temperature sensor of the heat exchanger of the indoor unit is faulty; d. The control circuit board of the indoor unit is defective; e. Refrigerant circulation failure
17 Power factor compensation (PFC) a. Faulty reactive power compensation device; b. Defective outdoor unit drive circuit board
18 DC compressor start error a. Incorrect connection or breakage of the compressor power cable; b. The outdoor unit integral power module (IPM) circuit board is defective; c. Defective outdoor unit control PCB d. Defective compressor
19 Compressor drive error a. Incorrect connection or breakage of the compressor power cable; b. The outdoor unit integral power module (IPM) circuit board is defective; c. Defective outdoor unit control PCB d. Defective compressor 7.fault elimination
20 Locked rotor protection of the outdoor fan motor a. Outdoor fan motor open circuit; b. The outdoor fan is blocked; With. The fan motor is defective; d. Defective outdoor unit control PCB

Hitachi error codes

Error codes for air conditioners of the Hitachi brand (Hitachi)


01 - malfunction of the reversing valve or does not correspond to the norm
media temperature.
02 - the mode is activated, forcibly starting the external module.
03 - there is no communication between the outdoor and indoor module.
04 - equipment malfunctions, you should pay attention to the readings
other indicators.
06 - irregularities were detected in the operation of the pump, which pumps out condensate.
07 - manual start of the pump is required.
08 - engine functions are violated.
09 - no communication with PCB thermistor.
10 - incorrect operation of the fan.
13 - PCB is not functioning.

Hyundai error codes

Error codes for Hyundai air conditioners (Hyundai)

0 - error in non-volatile memory;
E1 - an error occurred in connecting the blocks: indoor and outdoor;
E2 - malfunctions of the outdoor unit sensor;
E3 - malfunctions of the indoor fan motor;
E4 - there was an open circuit (short circuit) of the internal air temperature sensor;
E5 - there was a break (short circuit) of the evaporator temperature sensor;
EC - a coolant leak has occurred.

Jax error codes

Jax air conditioner error codes


E2 - there are malfunctions in the indoor air temperature sensor;
E3 - there are malfunctions in the evaporator temperature sensor;
E4 - there are malfunctions in the condenser temperature sensor;
E5 - an error occurred in the operation of the drainage pump;
E6 - protection in the external unit has been triggered;
E7 - failures in non-volatile memory;
E8 - the drain pan is full.

Kentatsu error codes

Kentatsu air conditioner error codes


E1 - there is no contact with the temperature sensor of the air in the internal
block;
E2 - there is no contact with the evaporator temperature sensor;

E4 - there is no contact with the outdoor air temperature sensor;
E5 - there is no contact between the indoor and outdoor unit;
E6 - warning about overheating or freezing of the outdoor unit;
E10 - there was a pressure failure in the compressor;
E13 - electricity is not supplied due to entanglement of wires;
E14 - supply of electricity to the wrong phase;
P4 - the evaporator has overheated;
P5 - condenser overheating has occurred;
P7 - exceeding the temperature level in the compressor;
P9 - frost protection turned on;
P10 - the value of the air outlet is incorrect;
P11 - the pressure during air intake exceeds the permissible limits;
P12 - supply of high voltage current;
HS - defrosting of the outdoor unit is in progress.
EC - Freon leak.

Kentatsu Models KSGH / KSRH

E1 - errors occurred in the non-volatile memory;
E2 - a failure occurred during the transformation of the zero cycle;
E3 - incorrect rotation of the fan;
E4 - supply of too high voltage to the compressor;
E5 - there was a violation of communication with the temperature sensor of the air inside;
E6 - there was a violation of communication with the evaporator temperature sensor.

Kentatsu Models KSFU / KSRU

P4 - the evaporator of the indoor module has overheated;
P5 - overheating of the outdoor unit condenser has occurred;
P9 - thawing is in progress;
E1 - no voltage to temperature sensors;
E2 - there is no connection with the evaporator temperature sensor;
E3 - there is no contact with the condenser temperature sensor;
E6 - there are malfunctions in the external module.

Duct type air conditioners

E0 - malfunctions of the temperature sensor in the room;
E1 - there are malfunctions in the operation of the evaporator temperature sensor;
E2 - there are malfunctions in the temperature sensor of the outdoor unit;
E3 - there is no communication with the outdoor module;
E4 - there are malfunctions in the condenser pump;
E5 - errors in non-volatile memory;
E6 - the condensate drain pan is full.

Lessar Error Codes

Lessar air conditioner error codes


E0 - an error occurred in the flow sensor;
E1 - a completely wrong phase sequence;
E2 - a communication error has occurred;
E3 - an error occurred in the temperature sensor of direct water;
E4 - an error has occurred in the temperature sensor of the shell-and-tube heat exchanger;
E5 - an error has occurred in the temperature sensor of the condenser pipe A;
E6 - an error occurred in the temperature sensor of the condenser pipe B;
E7 - an error has occurred in the outside air temperature sensor;
E8 - an error occurred in the compressor discharge temperature sensor
system A;
E9 - an error has occurred in the temperature sensor of the flow;
ЕА - there was a loss of communication with the slave units;
P0 - the pressure or temperature in system A is exceeded;
P1 - the pressure in system A has dropped;
P2 - pressure or temperature in system B is exceeded;
P3 - the pressure in system B has dropped;
P4 - there was an excess of current in system A;
P5 - there was an excess of current in system B;
P6 - the condensation temperature in system A is exceeded;
P7 - the condensation temperature in system B is exceeded;
P8 - temperature rise in the compressor;
Pb - frost protection.

LG error codes

LG air conditioner error codes (Elji)


01 - there was a short circuit in the sensor responsible for the air temperature,
or open circuit.
02 - there was a short circuit in the sensor responsible for the temperature
evaporator, or open circuit.
03 - a bad connection between the drive panel and
internal block.
04 - an error occurred in the operation of the drain pump or float
the sensor responsible for the level of condensation.
05 - fixed an error of inter-unit connection of internal and external
blocks.
06 - there was a short circuit in the temperature sensor responsible for the outdoor
block, or open circuit.
07 - internal multi-system units operate in different modes.
HL - the float sensor has opened.
CL - child lock activated.
Po - the device is operating in jet cool mode.

MDV error codes

Error codes for air conditioners MDV (MDV)


Free Match Series
Error indication on the indoor unit


Fault codes on the outdoor unit

Universal outdoor unit

Three-phase models with a capacity of 30, 36, 48, 60 Btu / h



Midea error codes

Error codes for air conditioners Midea (Midea)


E0 - an error occurred in the non-volatile memory of the indoor unit.
E1 - there was an error in connecting the outdoor and indoor units.
E2 - an error occurred when crossing zero.
E3 - an error has occurred when the fan motor is running.
E4 - short circuit or open circuit of the sensor responsible for the temperature of the internal
air.
E5 - short circuit or open circuit of the sensor responsible for the evaporator temperature.
EC - a refrigerant leak has been detected.

Mitsubishi Electric error codes

Error codes for air conditioners Mitsubishi Electric (Mitsubishi Electric)


P1 - an error of the sensors at the input is recorded.
P2 - error in the operation of the sensor responsible for the TH5 heat exchanger.
P4 - the drain pan is overfilled or the CN4F sensor has broken.
P5 - An error has occurred in the drain pump.
P6 - overheating or freezing has occurred.
P9 - error in the operation of the sensor responsible for the TH2 heat exchanger.
PA - the compressor is forced to stop.
E0, E3 - lost communication with the control panel.
E1, E2 - malfunctions in the control board.
E9, EE - there is no communication between the outdoor and indoor unit.
U1. Ud - the overheating protection has triggered, or is fixed in the 63H sensor
high pressure.
U2 - low pressure in the supercharger is detected, there is not enough refrigerant.
U3, U4 - short circuit or open circuit in the temperature sensor of the outdoor unit.
U5 - the condenser temperature is not correct.
U6 - fixed forced stop of the compressor or malfunction
power module.
U7 - lack of refrigerant or low pressure in the supercharger.
U8 - the motor of the fan installed on the outdoor unit is stopped.
U9, UН - undervoltage or overvoltage, or faults in
current sensor.
UF - compressor jammed or current overload fixed.
UP - compressor has been stopped due to overload.
Fb - malfunctions in the control board of the external unit.

Mitsubishi Heavy error codes

Error codes for air conditioners Mitsubishi Heavy (Mitsubishi Heavy)


E1 - there was a failure in the printed circuit board of the indoor unit or
malfunctions in the control panel;
E2 - there was a duplication of the addresses of the indoor units;
E3 - the address of the outdoor unit is incorrect;
E5 - there are malfunctions in the control board of the outer side;
E6 - there was a break (short circuit) in the evaporator sensor;
E7 - there was an open circuit (short circuit) of the sensor of the indoor unit;
E8 - the evaporator was overloaded;
E9 - error in the operation of the drain pump;
E10 - more than 16 units are connected to the control panel;
E11 - more than 1 block are connected to the control panel with an occupied address;
E12 - errors in address settings;
E14 - incorrect settings of the master and slave connections were made;
E16 - there are malfunctions in the operation of the indoor unit fan;
E28 - there are malfunctions in the control panel sensor;
E30 - there was an error in connecting the outdoor and indoor units;
E31 - implementation of incorrect address settings;
E32 - there is a wire break or the phase sequence is incorrect;
E33 - there was a break in the wire winding;
E34 - the winding phase has been opened;
E35 - malfunctions in the sensor or an increase in temperature in
condenser;
E36 - there was a deviation of the outlet air temperature above the norm;
E37 - there are malfunctions in the condenser temperature sensor;
E38 - there are malfunctions in the outside air temperature sensor;
E39 - malfunctions have occurred in the temperature sensor of the discharge pipe;
E40 - there was an increase in pressure in the system;
E49 - there was a decrease in pressure or the refrigerant is not enough;
E53 - malfunctions have occurred in the suction pipe thermistor;
E54 - the low pressure sensor is disconnected;
E55 - a malfunction occurred in the temperature thermistor inside the compressor;
E56 - there was a malfunction or breakage of the temperature sensor of the power
transistor;
E57 - insufficient amount of coolant;
E59 - the compressor is not started;
E60 - an error occurred in the positioning of the compressor;
E63 - an emergency shutdown of the indoor unit has occurred.

Neoclima error codes

Error codes for air conditioners Neoclima (Neoklima)

Code E0 - connection error between indoor and outdoor units.
E1 code - an error in the operation of the indoor unit. Lost communication with the controller.
Code E2 - an error in the temperature sensor.
Code E3 - the temperature sensor of the condenser tube is faulty.
Code E8 - irregularities in the heating system.
Code F0 - an error in the operation of the internal fan.
F2 code - the external protection system has been triggered.
Code F3 - protection in the high pressure system has been triggered.
Code F4 - protection in the low pressure system has been triggered.
F5 code - water overfill protection has been triggered.
F8 code - outdoor unit overheat protection has been triggered.
F9 code - wrong phase sequence. System error.
Code P4 - Compressor inverter air conditioner defective.
Code P6 - error in the operation of the outdoor EEPROM unit.

Panasonic error codes

Error codes for Panasonic air conditioners (Panasonic)


H00 - no problem found.
H11 - there is no communication between the outdoor and indoor unit or a problem
control boards.
H12 - the capacity of the indoor units does not match the outdoor one.
H14 - short circuit of the air sensor.
H15 - short circuit of the sensor responsible for the compressor temperature.
H16 - lack of freon in the external unit or the current circuit is broken
transformer board.
H17 - breakage of the sensor responsible for the temperature on the tube,
designed to dry the refrigerant.
H19 - jamming of the board, fan motor or connectors
wires.
H21 - the drainage system of the float sensor is faulty or clogged.
H23 - sensor 1, which is responsible for the evaporator temperature, is interrupted.
H24 - sensor 2, which is responsible for the evaporator temperature, is interrupted.
H25 - malfunctions in the ionization unit or internal board.
H26 - the ionizer is out of order.
H27 - short circuit of the sensor responsible for the outdoor temperature.
H28 - short circuit of the sensor responsible for the condenser temperature.
H30 - the sensor responsible for the discharge temperature is cut off.
H32 - short circuit of the sensor responsible for the condenser outlet temperature.
H33 - An error occurred in the interconnect.
H34 - short circuit of the sensor responsible for the temperature of the module heatsink.
H35 - a pump malfunction or drain blockage is detected.
H36 - short circuit of the sensor responsible for the temperature of the gas tube.
H37 - short circuit of the sensor responsible for the temperature of the liquid tube.
H38 - a mismatch between the outdoor and outdoor unit was detected.
H39 - freon circuits and wires are confused, or does not work
solenoid valve.
H41 - wires are not connected correctly.
H50 - faults in the board or fan motor.
H51 - nozzle clogged.
H52 - limit switch defective.
H58 - Patrol Sensor unit is defective.
H64 - the sensor responsible for high pressure is faulty.
H97 - malfunctions in the compressor motor or indoor unit board.
H98 - overheating protection defective.
H99 - Evaporator freezing detected.
F11 - the four-way valve does not work correctly.
F17 - the indoor unit is frozen.
F90 - the compressor winding is broken.
F91 - the refrigeration circuit does not work correctly.
F93 - the compressor winding is broken.
F94 - high pressure protection of the supercharger does not work.
F95 - the heat exchanger of the outdoor unit has overheated.
F96 - the power module has overheated.
F97 - Compressor temperature exceeded.

Pioneer error codes

Pioneer air conditioner error codes

Air conditioner error code Pioneer Yellow diode Green diode
Red diode

Pioneer air conditioner error decoding
E0 * Disrupted discharge temperature sensor function
E6 * The function of the condenser temperature sensor is broken
E6 * The function of the outdoor air temperature sensor is broken
E1 * The function of the temperature sensor in the room is broken
E2 * The function of the evaporator temperature sensor is violated
E3 mm The fan of the indoor unit is broken
E4 m * IPM system failure
E5 mm Power failure
E8 * m m Violation of supply voltage
E9 m Compressor started working incorrectly
EA * Incorrect communication with the outdoor unit
EC m * The air conditioner is supplied electricity invalid parameters
ITS EEPROM failure
EP No communication between external and internal modules
P0 Unit started incorrectly
P1 Discharge overheating
P2 Increased current in the circuit
P3 Mains voltage too high
P4 m m * No communication with the current relay
P5 Evaporator overheating
P6 Condenser overheating
P7 IPM Matrix Protection
* - the diode is on, m - the diode is blinking.

Error codes for outdoor unit Pioneer air conditioners:

Pioneer air conditioner error code (number of diode blinks) Pioneer air conditioner error decoding
1 No communication with the external temperature sensor
2 No communication with the condenser temperature sensor
3 No communication with the discharge temperature sensor
4 The current in the mains is too high
5 Mains voltage too high
7 No communication with indoor unit
9 Unit started up incorrectly
12 Mains voltage exceeded
13 IPM card protection
16 Overtemperature compressor
17 Discharge temperature too high
18 Condenser temperature too high
19 IPM card malfunction
20 Fault in communication of indoor and outdoor units
22 De-icing

Quattroclima error codes

Error codes for air conditioners Quattroclima (Kvatroklima)

Error or task
RUN indicator
Digital
display
Cause and troubleshooting
Switching to defrost mode
Flashes 1 time per second
dF
This is not an error.

Prevention of cold air supply
Flashes once every 3 seconds
The indoor fan does not rotate. This is not an error.
The service function of the air conditioner and its settings cannot be changed.
Room temperature sensor error
Flashes 2 times in a row every 4 seconds
E2



Pipe temperature sensor error
Flashes 3 times in a row every 5 seconds
E3
1. Check the resistance of the temperature sensor, if the resistance of the sensor is not correct for the current temperature, replace the sensor.
2. Check the sensor connection and continuity
3. The control board is defective, replace the board.

Outdoor unit error
Flashes 4 times in a row every 6 seconds
E4
1. Check compressor current and winding resistance.
2. Check the working pressure. In case of refrigerant leakage: remove the refrigerant residues and eliminate the leak, evacuate the system and charge according to the balance.
3. Check the outdoor unit pipe sensor.
4. Check the condenser of the outdoor unit, it must be clean, free of dust and dirt.
5. Check the operation of the outdoor unit fan.
6. The control board is defective, replace the board.
Indoor unit fan control error
Flashes 5 times in a row every 7 seconds
E5
1. Check the connectors connecting the fan motor to the control board.
2. Check the indoor fan motor.
3. Check the elements of the control board for damage. Replace damaged components or control board.
Internal error fees
Flashes 6 times in a row every 8 seconds
E6
1. Check the indoor fan.
2. Check the output signal from the control board. Replace control board.
Communication error between blocks
Flashes 7 times in a row every 9 seconds
E7
1. Check the inter-unit electrical connection.
2. Check compressor current and winding resistance.
3. Check the operating pressure.
overheat protection
Flashes 8 times in a row every 10 seconds
E8
1. Check the filters, they must be clean.
2. Check the fan operation of the indoor unit.
3. Check the indoor unit pipe sensor.
4. Check the operating pressure. In case of refrigerant leakage: remove the refrigerant residues and eliminate the leak, evacuate the system and charge according to the balance.

Samsung error codes

Samsung air conditioner error codes


E464 - An overload has occurred in the power module.
E461 - Compressor cannot be started.
E473 - Compressor blocked.
E466 - Incorrect voltage in the DC module of the board.
E221 - an error has occurred in the sensor responsible for the outdoor temperature
air.
E416 - overheating detected.
E251 - An error has occurred in the temperature sensor.
E468 - An error has occurred in the current sensor.
E465 - An error has occurred in the operation of the compressor.
E237 - An error has occurred in the temperature sensor winding.
E202 - Connection time elapsed.
E458 - an error occurred in the fan operation.
E471 - an error occurred in the operation of the OTP.
E467 - An error occurred while rotating the compressor.
E469 - An error has occurred in the voltage sensor.
E554 - refrigerant leak detected.
E472 - AC voltage error.
E121 - short circuit in the sensor responsible for the internal air temperature.
E122 - short circuit in the sensor responsible for the evaporator temperature.
E154 - An error has occurred in the fan of the indoor unit.
E101 - the time allotted for the connection has been exceeded.
E186 - An MPI error has been fixed.

Sanyo error codes

Sanyo air conditioner error codes

E01, E05, E14, E17 - an error occurred while receiving a communication signal;
E02, E04, E06, E10, E20 - an error occurred while transmitting the communication signal;
E03 - an error occurred in the remote control;
E07 - low power level of the indoor unit;
E08 - there was a duplication of the installation of the addressee of the indoor unit;
E09 - there was a duplication in the setting of the control panel;
E11 - duplication occurred during simultaneous multicontrol operations;
E15 - high power level of the indoor unit;
E16 - there is no connection of the elements of the indoor unit;
E18 - an error occurred while connecting to MDC;
E31 - errors occurred in the group settings of the indoor unit;
L01 - the types of indoor and outdoor units do not match;
L02 - duplication of the main unit has occurred in the group control;
L03 - there was a duplicate address in the outdoor unit;
L04 - group connection is made for the indoor unit;
L07 - address or group not set;
L08 - power in the indoor unit is not set;
L09 - an error occurred in setting the power of the outdoor unit;
L10 - an error occurred in the connection of control circuits;
L11 - there was an error in setting the capacity of the indoor unit;
L13 - as a result of connection ceiling panel There has been a breakdown;
P01 - malfunctions of the float relay;
P03 - there are problems with power supply;
P05 - no gas;
P09 - overheating has occurred;
P10 - there are problems with the discharge temperature;
P15 - 4-code valve blocked;
P19 - cooling is overloaded;
P20 - malfunctions of the outdoor unit fan;
P22, P26 - malfunctions of the compressor inverter;
P29 - errors in multicontrol operation when performing simultaneous operations;
P31 - overload in the compressor;
H01, F02 - malfunctions of the temperature sensor of the indoor unit;
F01 - malfunctions of the temperature sensor in the outdoor unit;
F04, F06, F07 - violation of the temperature mode in the outdoor unit;
F08 - violations in the intake temperature mode;
F10 - violations in the discharge temperature mode;
F12, F29, F31 - errors in the internal non-volatile memory.

TCL error codes

TCL air conditioner error codes (TCL)

E0 RUN 、 TIMER –both winking In and out communication failure. No communication between outdoor and indoor units, check the interconnection, indoor and outdoor unit boards
EC RUN 、 TIMER –both winking Outdoor communication failure Open communication failure
E1 RUN-1 time / 8s Outdoor sensor outdoor sensor
E2 RUN-2 times / 8s Indoor coil temperature sensor Malfunction of evaporator temperature sensor
E3 RUN-3 times / 8s Outdoor coil temperature sensor Faulty condenser temperature sensor
E4 RUN-4 times / 8s System abnormity System abnormal
E5 RUN-5 times / 8s Type mismatch Type mismatch
E6 RUN-6 times / 8s Indoor fan motor Indoor unit motor error
E7 RUN-7 times / 8s Outdoor temperature sensor Outdoor unit temperature sensor
E8 RUN-8 times / 8s Discharge temperature sensor Compressor discharge temperature sensor
E9 RUN-9 times / 8s Invert module abnormity Inverter board defective
EF RUN-10 times / 8s Outdoor fan motor (DC) Outdoor fan motor
EA RUN-11 times / 8s Current sensor Current sensor
EE RUN-12 times / 8s EEPROM failure ROM, firmware failure.
EP RUN-13 times / 8s Top of compressor temperature switch Compressor cut-out thermostat
EU RUN-14 times / 8s Voltage sensor Voltage sensor
EH RUN-15/8 sec Intake temperature sensor Suction pipe temperature sensor

Emergency stop

P1 RUN: Blink; TIMER: 1 blink / 8 sec Overvoltage / undervoltage protection Low / high supply voltage
P2 RUN: Blink; TIMER: 2 blink / 8 sec Overcurrent protection Overcurrent protection
P4 RUN: Blink; TIMER: 4 blink / 8 sec Exhaust overtemperature protection Exhaust gas overheating protection
P5 RUN: Bright; TIMER: 5 blink / 8 sec Subcooling protection under cooling mode Subcooling protection in cooling mode
P6 RUN: Bright; TIMER: 6 blink / 8 sec Overheating protection under cooling mode Overheating protection in cooling mode
P7 RUN: Bright; TIMER: 7 blink / 8 sec Overheating protection under heating mode Overheating protection in heating mode
P8 RUN: Bright; TIMER: 8 blink / 8 sec Outdoor overtemperature / undertemperature protection Outdoor overheat / overcooling protection
P9 RUN: Blink; TIMER: 9 blink / 8 sec Drive protection (software control)
P0 RUN: Blink; TIMER: 10 blink / 8 sec Module protection (hardware control) Module protection (hardware control)

Toshiba error codes

Toshiba air conditioner error codes (Toshiba)


00-0C - error in the board of the indoor unit or sensor responsible for
air temperature inside the device.
00-0d - error in the control board or sensor responsible for
radiator temperature.
00-11 - malfunctions in the motor or fan board.
00-12 - repair or replacement of the control board is required.
01-04 - the board or fuses on it burned out, interconnection
installed incorrectly.
01-05 - An error was recorded in the inverter board.
02-14 - an overload is detected in the inverter.
02-16 - there was a short circuit in the compressor windings.
02-17 - an error occurred in the current sensor.
02-18 - an error occurred in the temperature sensors.
02-19 - an error occurred in the board temperature sensor.
02-1A - burned out or blocked motor or board.
02-1b - malfunction in the board or sensor responsible for the board temperature.
02-1С - the compressor did not have time to start in the allotted time.
03-07 - an error has occurred in the inverter board or a deficiency is noticed
refrigerant.
03-1d - the compressor is defective.
03-1E - an error has occurred in the sensor responsible for the suction tube.
03-1F - the refrigeration circuit is overloaded or the voltage in the compressor is too low.
03-08 - the four-way valve is faulty.

There is "CHEK" on the remote control, press it, direct the remote control to the air conditioner and use the temperature arrows to scroll through the codes, the air conditioner will produce a signal on the fixed codes. This will determine the error code, and you can also reset it. If the error is not critical.

Zanussi error codes

Error codes for air conditioners Zanussi (Zanusi)

Error codes displayed in the indoor unit
Error code Fault Indication on the display Note
E2 Room temperature sensor malfunction TIMER lamp blinks at 5 Hz
E3 Evaporator probe failure START lamp flashing at 5Hz
E5 Condenser probe failure Defrost lamp blinks at 5Hz The system will automatically operate correctly after the failure is eliminated
F5 Malfunction of the float switch of the drain pan Alarm lamp flashes with a frequency of 5 Hz
F2 Fault in the outdoor unit Defrost and alarm lamp blinks at a frequency of 5 Hz
P6 Fault EEPROM START and TIMER lamps flashing at 5Hz The system will operate normally after a complete shutdown.

Indication of error codes in the external Zanussi unit
Fault Indication on the board
Low pressure protection Blinks 4 times every 6 seconds
High pressure protection Flashes 3 times every 5 seconds
Reverse phase protection Blinks 9 times every 11 seconds
Overcurrent protection Flashes 7 times every 9 seconds
Outside temperature sensor failure Flashes 5 times every 7 seconds
Outdoor heat exchanger overheat protection Blinks 2 times every 4 seconds
Defrost protection Flashes once every 3 seconds
EEPROM error Blinks 8 times every 10 seconds

With Gree air conditioners and split systems, repairs are easier than those of the hi-fay series.

Self-diagnosis of Gree air conditioners

How can the average person ask this?

The explanation is simple Gree: codes. On Gree air conditioners and split systems, there are not many protection sensors. Those. everything is simplified.

  • Internal self-diagnostics of Gree air conditioners unified and almost identical in terms of error positions of inexpensive air conditioners, for example, such as Pioneer, General Climate, Lessar and others.

You will laugh, but for example, the catalog of Supra air conditioners has not even changed the name of the outdoor unit, perhaps there is not enough Photoshop skills, perhaps they did not consider it necessary.

In a word, how were Supra air conditioners certified in Russia? It's a mystery to me. Supra catalog !! In fact. Heh ...

Self-diagnosis of Gree air conditioners is, -

  • high pressure protection,
  • protection against freezing of the evaporator,
  • Compressor overload protection,
  • Errors in the commutation of the air conditioner during installation, I confuse the wires,
  • And errors in the temperature sensors of the evaporator and condenser.

That's all, you must agree not a lot. Gree, like an air conditioner, is simple in function, so there are not many error codes.
There are disadvantages of this simplification - these are weak varistors of the control board, insufficient smoothing

Error codes table, continued.

currents with voltage surges. A trifle, but this must be borne in mind when repairing air conditioners Gree and their analogues.

Example: a country house. Leaving the dacha, the owners usually de-energize the building with a general switch.
Those. extinguished and everything, calmed down. We arrived ... They turned on the light with the same switch, but the air conditioner, refrigerator, or other household appliances did not work. Why? The answer is simple.

When the power is turned on with the load, current and voltage surges occur.

Varistors that smooth out voltage surges do not cope with the current load and burn out, burn well with smoke and soot, in the absence of a protective shell, as a rule, together with the fuse of the control board of the internal block of the split system.

There are "experts" who use wire when blowing a fuse. Can I do this? It is possible, but then, in addition to the varistors, the control board, the fan motor of the indoor unit will also burn out, and ... it rushed up to the compressor windings of the outdoor unit of the air conditioner.

Fireworks in the country. - Expensive renovation.

Troubleshooting and breakdowns of the air conditioner, Gree: as usual, we start the codes with ...

- refrigeration circuit malfunctions,

- malfunctions of the electrical part, electrical system. power supply and air conditioner control.
A source:

Error map, map making. Primary system diagnostics.

GREE Air conditioners for semi-industrial, industrial use, - error codes.

Error code = E1
Compressor, pressure surges (horn).

Error code = E2
Coil defective

Error code = E3
Low pressure air conditioner compressor tripped (horn)

Error code = F0
Defective room temperature sensor.

Error code = F1
Wrong sensor resistance.

Error code = F2

  • The temperature sensor of the outdoor unit of the air conditioner has been triggered.

Error code = F3
The temperature sensor circuit is open.

GREE Split Air Conditioners Error Code ...

The cause of the malfunction, - the refrigerant system with a high degree of protection, - the pressure.
code = E1

Gree LED blinks 1 time.
Indicator, - cooling =
Heating indicator =

Cause Gree malfunction, - frost protection.
code = E2

Air conditioner start LED = LED blinks 2 times.
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Compressor exhaust high temperature protection.
code = E4

Air conditioner start LED = blinks 4 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction - AC overcurrent protection
code = E5

Air conditioner start LED = LED flashes 5 times
Indicator, - cooling =
Heating indicator =

The cause of the malfunction is a communication failure between the indoor unit of the air conditioner and the outdoor unit of the split system.
code = E6

Gree air conditioner start LED = blink 6 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Anti-high temperature protection
code = E8

Air conditioner start LED = blinks 8 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction - No feedback of the internal fan motor
code = H6

Air conditioner start LED = flashes 11 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Jumper cap is defective.
code = C5

Air conditioner start LED = flashes 15 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Closed ambient sensor open, no contact or short circuit
code = F1

Indicator, - cooling = LED flashes 1 time
Heating indicator =

Name of sensor malfunction or breakage = Indoor tube open, no contact or short circuit
code = F2

Air conditioner start LED =
Indicator, - cooling = LED flashes 2 times
Heating indicator =

The cause of the malfunction is the outdoor ambient sensor is open, no contact or short circuit
code = F3

Air conditioner start LED =
Indicator, - cooling = LED flashes 3 times
Heating indicator =

Cause of malfunction - Outer tube sensor open, no contact or short circuit
code = F4

Air conditioner start LED =
Indicator, - cooling = blinks 4 times
Heating indicator =

Name = malfunction or breakage of the exhaust sensor open, no contact or short circuit
code = F5

Air conditioner start LED =
Indicator, - cooling = LED flashes 5 times
Heating indicator =

Cause of malfunction - Over load limit / underfrequency
code = F6

Air conditioner start LED =
Indicator - Cooling = Blink 6 times
Heating indicator =

Cause of malfunction - For limiting the current / output frequency
code = F8

Air conditioner start LED =
Indicator, - cooling = blinks 8 times
Heating indicator =

Cause of malfunction - High exhaust gas temperature limit / frequency reduction
code = F9

Air conditioner start LED =
Indicator - cooling blink = 9 times
Heating indicator =

Cause of malfunction - Overvoltage protection for PN
code = PH

Air conditioner start LED =
Indicator, - cooling = flashes 11 times
Heating indicator =

The cause of the malfunction is the AC fault detection.
code = U5

Air conditioner start LED =
Indicator, - cooling = flashes 13 times
Heating indicator =

Cause of malfunction - Compressor reverse protection
code = U4

Air conditioner start LED =
Indicator, - cooling = blinks 14 times
Heating indicator =

Cause of malfunction - For compressor phase current protection
code = P5

Air conditioner start LED =
Indicator, - cooling = flashes 15 times
Heating indicator =

The cause of the malfunction is the malfucntion input by the sensor tube
code = b5

Air conditioner start LED =
Indicator, - cooling = flashes 19 times
Heating indicator =

Cause of malfunction, - Open DC fan motor is defective.
code = L3

Air conditioner start LED =
Indicator, - cooling = blinks 21 times
Heating indicator =

Cause of malfunction - Output malfunction or breakdown of the tube sensor
code = b7

Air conditioner start LED =
Indicator, - cooling = flash 22 times
Heating indicator =

Cause of malfunction, - Compressor overload sensor is defective.
code = FE

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Defrosting
code = h3

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = LED flashes 1 time

Cause of malfunction - static protection against dust cleaning
code = H2

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = LED flashes 2 times

Cause of malfunction - Compressor overload protection
code = H3

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = LED flashes 3 times

Cause of malfunction - System abnormal protection
code = H4

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = blinks 4 times

The cause of the malfunction, - IPM protection
code = H5

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = LED flashes 5 times

Cause of malfunction - PFC protection
code = HC

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 6 times

Cause of malfunction - Compressor step loss protection
code = H7

Air conditioner start LED =
Indicator, - cooling =
Heating indicator flash = 7 times

Cause of malfunction - Heating against high frequencies temperature drop
code = HO

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 10 times

Cause of malfunction - Startup failure
code = Lc

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 11 times

Cause of malfunction - Compressor for phase failure protection
code = U2

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 12 times

Cause of malfunction - Phase current compressor is defective.
code = U1

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 13 times

Cause of malfunction - Compressor demagnetization protection
code = HE

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 14 times

Cause of malfunction, - EEPROM download is defective.
code = EE

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 15 times

The cause of the malfunction is a communication failure between the motherboard and the driver of the board
code = P6

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 16 times

The cause of the malfunction is a malfunction of the charge capacitor
code = PU

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 17 times

The cause of the malfunction, - the sensor circuit IPM is faulty.
code = P7

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 18 times

The cause of the malfunction, - IPM high-temperature protection
code = P8

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 19 times

Cause of malfunction - PN protection voltage drop
code = U3

Air conditioner start LED =
Indicator, - cooling = blinks 20 times
Heating indicator =

Cause of malfunction - low voltage protection PN
code = PL

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 21 times

Cause of malfunction, - Current detection circuit is defective. Or malfunction or breakage of current sensor
code = Pc

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Compressor phase failure protection
code = Ld

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Compressor or rotary protection blocked
code = LE

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction, - IPM is more than the temperature limit / frequency decrease
code = EU

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - 4-way reversal valve abnormal
code = U7

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction is the disconnection of the exhaust gas temperature sensor
code = U8

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - AC zero voltage error detection
code = U9

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - Frequency temperature drop for the tube
code = FA

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Anti-freeze limit / frequency reduction
code = FH

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Models: air conditioner repair brands KFR-32GW / BP, KFR-45LW / D, KFR-3502GW / BP, KFR-2501GW, KFR-45LW, KFR-3301GW, KFR-3201GWCPU, KFR-2608GW / BP and other KFR series, PDF fail.

AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), Vitek, - digital display for a series of air conditioners faults:

  • Display mode = E4
  • Priority level display = 1 Non-mitsubishi52_63_71he-s power supply defective = Plastic temp sensor is abnormal.
  • Display mode = E1 Display priority level = 2
  • Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3
  • Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = E2 Priority level display =
    4

2.H series - AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), Renova (except KFR-25G / H) h3 HA HB series malfunction display:

  1. Power supply failure = PG motor feedback abnormal
  2. Priority level display = 1 Power supply failure = Plastic sensor temp abnormal Display mode = Timer LED blinks 1 time every 8 seconds
  3. Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds
  4. Priority level display = 3 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 1 time every 1 second
  5. Display priority level = 4

3. Series H (Y) air conditioner model remote display, removable panel AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu:

  1. Power supply failure = PG motor feedback abnormal Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1
  2. Power supply failure = Plastic temp sensor. abnormal Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2
  3. Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3
  4. Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = Timer LED blinks 1 time every 1 second Priority level display = 4

4. E. E. E. Yu. EC EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display series of air conditioners AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), troubleshooting:

Power supply failure AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = PG motor feedback abnormal Display mode = E4 Priority level display = 1

E1 or EL - as a common power error.

Malfunction of the power supply or, in Russian, the voltage in the network< 210 В (сработала защита – токовая нагрузка) = Датчик темп ненормально Режим отображения = E1 Отображение уровня приоритета = 2

E1 is a fairly common mistake, I ran into it just yesterday.

    The reasons for E1 are obvious - insufficient mains voltage< 210 В. При пуске компрессора происходит дополнительная просадка напряжения, токовая нагрузка max.
    Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3

1

1

5. All other E series, except EA EC E. M. E. Yu. Z. EAA EAD:

Power supply failure = PG motor feedback abnormal

Display mode = Timer LED blinks 4 times every 8 seconds

Priority level display = 1 Power supply failure = Plastic temp sensor. abnormal Display mode = Timer LED blinks 1 time every 8 seconds

Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3

6. QA QB QD digital display series of air conditioners AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), Vitek, Renova - malfunctions, error codes:

  • Power supply failure = PG motor feedback abnormal Display mode = E4
  • Priority level display = 1 Power supply failure = Plastic sensor temp abnormal Display mode = E1
  • Priority level display = 2 Power supply failure = Copper temperature sensor abnormal
  • Display mode = E3 Display priority level = 3 Power supply fault = overcurrent oprotection
  • Display mode = E6 Display priority level = 4

1

1

7.QC QQ light display air conditioner series malfunction:

  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1 Power supply failure = Plastic temp sensor abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2 Power supply failure AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = Copper temperature sensor abnormal
  • Display mode = Timer LED blinks 3 times every 8 seconds Priority level display = 3 Power supply failure = overcurrent oprotection
  • Display mode = Timer LED blinks 6 times every 8 seconds Priority level display = 4

1

1

8. Display malfunctions of semi-industrial series 18000BTU ~ 24000BTU, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), Renova - wall-mounted series of air conditioners:

  • Numbers for digital handset displays:
  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2
  • System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode =
  • Timer LED blinks 2 times every 8 seconds Priority level display = 3 System errors = turns off
  • Power supply failure = Copper temperature sensor abnormal Display mode = Timer LED blinks 8 times every 8 seconds Priority level display = 4
  • System errors = does not turn off Digital tube displays: Power supply failure = PG motor feedback abnormal Display mode = E1
  • Priority level display = 2 System errors = turns off Power supply failure = Plastic sensor temp abnormal Display mode = E3
  • Priority level display = 3 System errors = turns off Power supply failure = Copper temperature sensor abnormal Display mode = E2 Priority level display = 4
  • System errors = does not turn off

Error codes are needed if your split system has broken down, how to fix the problem, what the consumer also needs to know, so that you are not cheated at the service center.

Split systems error codes

Possible breakdowns refrigeration technology determined by error codes, it is not necessary to be an expert to determine the cause of the breakdown by codes

The main directions of troubleshooting are simple ... If the error code F-1, F-2, F-3, F-4, F-5, F-6, F-7, etc. is displayed, then the problem should be looked for in the temperature sensors and everything connected with them on the control board does not pass a signal, an open or a short circuit.

If the error code E-1, E-2, E-3, E-4, E-5, E-6 ... etc. is displayed. E-0, EL, while the air conditioner either starts and works for some time, or does not start at all, then we are looking for a solution to the problem with the operation of the split system in the power unit: the reasons are different ... from the complete failure of the signal to start up to the critical current characteristics for shutting down the system ...

As an example: the fan bearing of the indoor unit is pinched, the fan impeller rotates but with insufficient speed, the hall sensor or torque sensor does not send a signal to the control board, the split system gives an E 1 ... E-L error after 1-5 minutes, the problem is found.

Malfunctions and malfunctions of Toshiba air conditioners, we fix errors in the operation of your favorite split system

  • Error codes 00, air conditioner power supply malfunctions, critical malfunctions
  • Table of malfunctions and possible malfunctions, repair methods and troubleshooting of Toshiba air conditioners
  • We repair Toshiba, fault tables and error codes for professionals, errors from 14 to 22
  • toshiba_mul "ti system errors with two or more internal ones ... and much more, everything is on this page of the site.
It is easy and simple to repair Toshiba air conditioning systems if you have a service manual, we give you the opportunity for free to become at least a little bit smarter.
Toshiba RAV series - air conditioner problems or error codes

Samsung Air Conditioner Remote Control

Air conditioner control panel Samsung, is not just a set of buttons that set certain preset functions an air conditioner, but this is also a programmer, tasks are the firmware of the split system board itself.
    On the remote, using certain successive button presses, you can display like cockroaches and fix Samsung errors.
P / U Fig. 1.
But, if, nevertheless, your Samsung got into trouble, - Samsung broke, do not rush to call the service center for the repair of air conditioners, try to re-flash the air conditioner board and return the Samsung split system settings to the factory settings.
Samsung - Air Conditioner Fault Codes | Samsung board firmware

Sources: error codes of popular air conditioners Error Code Air Conditioner ...

welcome to the page with direct links to sources of information about error codes, malfunctions of split systems of industrial and VRV air conditioning systems, the source sites also provide information about chiller - fan coil systems, fault codes and major breakdowns of climatic equipment. Air Conditioner Hardwired Remote Controller System Error Codes.
Mitsubishi, Fujitsu, Acson, Dantex, Mitsubishi-Heavy, Chofu, Akira, General Electric, General Climate, Gree, General-Fujitsu, Sanyo, Daikin, Toshiba, Electrolux, Kentatsu, Neoclima, Midea, McQuay, Panasonic, AUX, West, Whirlpool, Yamaha, Euronord, Pioneer, Mitsubishi-Electric, Hyundai, Dantex classik Toyo, Chigo, DAX, RODA, Renova, Quattroclima, Lessar, Supra, Saturn, Ferroli, Hualing, Tadiran, Daewoo, Airwell, York ...

If you didn't find your air conditioner in this long list, don't worry, click on the source link ... it's all there.

Error code air conditioning | Error codes, originals pdf file

Damaged thermistor

1) Check the transmission wire. 2) Check with another remote controller. If "EO" is still indicated, replace the internal controller board. If another checkered code appears. replace the original remote controller. Error codes. Mitsubishi-Electric

P1 Room temperature thermistor abnormality (RT1) 1) Bad thermistor contact 2) Damaged thermistor 1) Check the thermistor. 2) Measure the resistance of the thermistor. Normal resistance should be as follows. 32 ° F-15k | 86 ° F ..... 4.3k 50 ° F ...... 9.6k 104 ° F ..... 3.0k 68 ° F ...... 6.3k, If the resistance is ok, replace the inner tip dispatchers. P2 Internal coil thermistor abnormality (RT2) P3 Signal transmission error (The remote controller does not respond to the controller's internal signal.) 1) Bad contact of the transfer wire 2) The signal transmit / receive circuit is not correct. 3) Wrong operation due to noise wave emitted by other devices

1) Check the transmission wire. 2) Check with another remote controller. If "P3" is still indicated, replace the inner board. If another checkered code appears, replace the original remote controller. 3) Short circuit between and out of CN40 and apply CN40 to the following units. Second unit in double control Second and third units in triple control Sub units in P4 group control Leak sensor abnormality 1) Bad transmission contact cables
Mitsubishi-Electric air conditioners | Split systems malfunctions, error codes

Break much more often

Frequent breakdowns of air conditioners of the budget series are due to the fact that split systems of a lower price category break down much more often, since almost all units, parts, and mechanisms of coolers are minimized in price.

Error codes for air conditioner groups - DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Renova, - with the same interchangeable printed circuit boards.

Error codes of entire groups of budget air conditioners - DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Vitek, Daihatsu, Renova, - with the same name interchangeable printed circuit boards. The firmware of the board of cooling devices of these brands by default.

E1 or EL - pay close attention to this malfunction in the operation of the air conditioner, it is usually not related to the quality of the cooler's operation, it is an external system error associated with a low-quality voltage in the power supply network.

Error display code | AUX, DAX, JAX, Pioneer, Hansa, Saturn, Vitek, Rolsen, Yamatsu, Daihatsu

Breakdown of Mitsubishi-Heavy split systems

Display readings on the Mitsubishi remote control.

Error code EA Why isn't Mitsubishi working? Incorrect installation of the Indoor / outdoor unit. exceeds the number of internal inclusions, connecting block, open circuit. Check temperature and pressure sensors ...

Error code Eb Malfunction of the split system. Incorrect installation of the Indoor / outdoor unit. (Incorrect installation, check correct connection) Check temperature and pressure sensors ...

EC error code Problem. Start on time, delay start. Check temperature and pressure sensors ...

Error code E6 Malfunction. Internal / external, - malfunction of the control board (the signal receiver does not work). When checked, it is closed,

Error code E7 Malfunction of the Mitsubishi air conditioner. Internal / external, - incorrect signal formation (incorrect connection, open circuit, short circuit). When checked, it is closed,

Error code E8 Malfunction of the Mitsubishi-Heavy air conditioner. Internal / external, - malfunction of the control board (the signal receiver does not work).

Mitsubishi-Heavy, troubleshooting the cooling circuit.

We eliminate the malfunctions of the cooling circuit.

Check temperature and pressure sensors ...

Error code E9 Air conditioner malfunction. Internal / external, - incorrect signal formation (incorrect connection, open circuit, short circuit). Check temperature and pressure sensors ...

Mitsubishi-Heavy Cooling System Malfunctions, Service Manual

Search malfunctions and breakdowns of split systems McQuay / Acson, it is necessary to start with the common causes of breakdowns and equipment failure. Common causes include electrical malfunctions and malfunctions of the refrigeration circuit.

Name of equipment McQuay / Acson, their analogues and modifications.
McQuay… McQuay and Acson, - Potential Malfunctions and Errors

Broken air conditioner Carrier

If your Carrier air conditioner breaks down, then something really extraordinary has happened and goes beyond the bounds of reason.

Carrier, - so reliable and durable that they break this device extremely difficult even with a strong desire. But, anything happens ... meteorites fall ... Carrier split systems malfunctions

The main malfunction of LG air conditioners ...

As a rule, the main malfunction of LG air conditioners is insufficient mains voltage, electrical consumption. Chubays are spoiling LG air conditioners. How to fix the breakage? How to identify a malfunction using blinking indicators. What do these blinks mean?

How many times this or that indicator light blinked, you can see focusing on the figure above. How to find an error using indicators - LEDs of the indoor unit of air conditioners.
How many times this or that indicator light blinked, you can see focusing on the figure above.
  • Error code = 21, as an example in the picture.
  • You may have a different error code, but the analogy is clear.
  • Error codes for both conventional split systems and multi air conditioners
  • LG with two or more indoor units, examples of error codes taken from the indoor unit of a multi-split system, as an example:
LG, - air conditioner code error tables | How to identify the problem ... LG error codes

Haier air conditioners also break down like all household appliances, fault codes and possible mistakes in split systems of this brand, you can easily determine by the table of malfunctions given on the page of our website.

The operation algorithm of Haier Electric Corporation air conditioners is so simple that even a novice amateur repairman can figure it out.
If all repair work is carried out sequentially, then the result simply must be positive.

Haier Electric Corporation error codes

Incorrect Haier air conditioner maintenance is the main malfunction. Crooked arms are the reason that disables Haier's split systems.
  • Crooked arms are the reason that disables Haier's split systems.
  • Haier Electric Corporation. Models of the HSU-HVA R2-4 series air conditioner error codes.
  • Model HSU-09 / 12HVA103 / R2 (OBD) or their analogs
  • Model HDU-24CA03 / M (R1) HDU-28CA03 / M (R1) HDU-36CA03 / M (R1) HDU-42CA03 / M (R1)
Haier fault codes | Model HSU-09 / 12HVA103 / R2 or their analogs

Panasonic, air conditioner repair. We are looking for and fixing system errors. Error codes and malfunctions of Panasonic air conditioners (Panasonic).

Panasonic How To Resolve An Unexpected Problem

To be fair, we note that Panasonic air conditioners also break down.

Breakdowns and malfunctions in split systems under the well-known multi-national brand National Panasonic, as well as the main malfunctions of split systems, are presented in our article on the repair of coolers of this type.

If your Panasonic blinked like a Christmas tree and does not want to execute the commands given from the air conditioner control panel, then this article will help you figure out and fix the unexpected problem. Everything is being repaired! Even National Panasonic split systems. To be fair, we note that Panasonic air conditioners also break down.

We are looking for and fixing system errors. Panasonic error codes.
  • Panasonic, how to find the error code, it is not difficult to determine the breakdown of the air conditioner, you need to carefully observe the display and look at the Panasonic error map. There is a drawing.
In order to order a repair of a panasonic air conditioner from us, it is enough to call our operator and leave a request. … Repair of Panasonic air conditioners. Name of service. Price, rub
Panasonic air conditioner repair | We look for and fix system errors

Gree, like an air conditioner, is simple in function, so there are not many error codes. The disadvantages of the simplicity of Gree air conditioners are weak varistors of the control board, insufficient smoothing of currents during voltage surges. A trifle, but this must be borne in mind when repairing air conditioners Gree and their analogues.

Self-diagnosis of Gree air conditioners

The internal self-diagnostics of Gree air conditioners is unified and almost identical in terms of error positions of inexpensive air conditioners, such as Pioneer, General Climate, Lessar and others.
Everything is similar and almost everything is being repaired: you just need to have a little patience and confidence in the success of the repair company. Everything will be fine...
Gree: error codes and malfunctions | Simple renovation

Daikin error codes ... Malfunctions of these glorious Daikin Daichi air conditioners. Air conditioner malfunction definition table Daikin. Full size of the image. 2500 * 2000 ref.

Error codes, click on the PU Daikin buttons.

What and when buttons to press? Schematic version. The screen will display the error code of the split system. It is very convenient for self-checking. And, then there are cases, a "master" for repair comes and ... let's wind up the price for the repair of the air conditioner from the eyes of the client. And there the problem is a penny. As an example, wipe the thermal sensor of the indoor unit with a cloth, or just clean the filter ...
Self-troubleshooting of Daikin air conditioners. Pre repair diagnostics of Daikin split systems.
Daikin error codes | Faults of Daikin air conditioners

Fault codes Fujitsu, General-Fujitsu | What and when to press the buttons? Repair

We look at the book and see ... what is needed. The malfunction paradox Fujitsu, General-Fujitsu. Fault codes of split systems Fujitsu, General-Fujitsu. Fujitsu, General-Fujitsu, Fuji... Air conditioner fault codes, system error monitoring or Fujitsu System Controller Error. When EE: EE is displayed on the Fujitsu remote control - press the power saving and the mode change button at the same time hold the buttons for more than 3 seconds. Error codes will be shown on the display. (1) Stop the air conditioner. (2) Press the Master control button and the fan control button at the same time for 2 seconds or more to start the test run (3) Press the Start / Stop button to stop the test run Error code = 01 Fault = Communication error (indoor unit with outdoor unit) Error code = 02 Malfunction = indoor temperature sensor open, open Error code = 03 Malfunction = Indoor unit temperature sensor, - short circuit Error code = 04 Malfunction = Air conditioner indoor unit temperature sensor is open Error code = 05 Malfunction = Indoor unit temperature sensor is faulty. Sensor resistance 10 Ohm. Error code = 06 Fault = outdoor heat exchanger temperature sensor open Error code = 07 Fault = external heat exchanger temperature sensor short circuit Error code = 08 Fault = power to connect to the error source Error code = 09 Fault = Float switch Error code = 0A Fault = Outdoor unit temperature sensor open or open Error code = 0b Fault = Outdoor unit temperature sensor of a split system, - short circuit Composite picture of service manual Fujitsu, General-Fujitsu. Original. Fault = no signal from Fujitsu, not normal Error code = 14 Fault = no signal from room sensor 2. Outdoor LED block Fujitsu. When the outside temperature drops, there is not enough pressure in the system. Add freon. error: heat and cooling (REVERSE CYCLE) Fujitsu wrong connection.

Baloo air conditioner error codes are required in order to identify the malfunction in a timely manner and contact the master to fix it. It should be noted that in some cases the slightest delay becomes critical, so it is better to monitor the appearance of information on the scoreboard.

True, the errors of Balu air conditioners directly depend on the series. After all, the equipment differs in software, which means that it informs a person about malfunctions in different ways. This means that all possible codes should be considered depending on the series.

Errors on the example of Ballu MFS2

Errors of air conditioners Balu of the MFS2 series:

  • E1, E2, E3, E4 - an error of the Ballu air conditioner, indicating that the temperature sensor has been cut off or short-circuited;
  • E6 shows emergency activation of the protection of the outdoor unit;
  • E8 - an error of the Ballu air conditioner, which requires cleaning the electrostatic filter;
  • P4 - the compressor automatically turned off, as an error appeared on the evaporator sensor, which occurs when the temperature threshold is exceeded;
  • P5 - this error code Ballu air conditioner shows when an error appears on the condenser sensor;
  • P6 will prompt that defrosting has started automatically.

The number of codes shows how much information a person receives about the operation of his own equipment.

Accordingly, he can contact specialists at the right time.

Below is the most complete list of error codes and malfunctions found in this technique in general.

Errors of the Balu air conditioner of the BSC, BR, BV series

  • E1, this error code of the air conditioner is displayed when the indoor air temperature sensor does not work properly;
  • E2 - error of the evaporator temperature sensor;
  • E5 indicates that an error occurred in the outdoor unit, which led to the automatic activation of the protection mode;
  • E6 - these are errors of Baloo air conditioners, showing a malfunction of the fan motor in the indoor unit.

It is immediately clear that the number of codes for the last three episodes is significantly less. On the one hand, this shows how stable the models are considered. On the other hand, the user receives less information, which often leads to difficult situations and additional diagnostics of cassette air conditioner models.

Air conditioner error codes are useful information that appears on the equipment screen. If you correctly recognize them, then you will be able to know exactly what kind of malfunction should be eliminated. Because of this, maintenance takes a minimum of time, which means that the owner does not have to suffer from a lack of technology.