Hinged boiler Navien: characteristics. Gas boiler Navain - Instructions for safe use and care boiler Navain Ace Instructions for use

Instructions for the use of gas boiler Navaine colorfully describes the sequence of execution of commands to manage this device, which is able to act under such conditions when the technique from competitors simply stops.

In favor of this says how completely electronic system Management and key principles used to adjust the boiler operation. Naven, the product from the Korean manufacturer is reliable, steady, can cope with frankly emergency operating conditions.

Key features of products

The boiler is distinguished by a low price. Nevertheless, the instruction of the gas boiler is very detailed, the installation of any modes is thoroughly painted. Thus, it can be understood how seriously the manufacturer approached the report of the main aspects of the management of the usual buyer. Users will not have problems with setting up and using the device.

The same goal follows the electronic control system, as well as adjusting other key parameters. To understand how universal equipment is Navien, we give a brief list of its abilities for work under non-standard conditions.

  1. To protect and smooth out voltage tension, the regulation circuit used by the chip microprocessor is applied. If the electronics parameters are changed, it supports the mode that allows you to function normally to all components of the boiler. This not only extends the service life of the unit, but also eliminates some faults of the gas boiler Navien, which could be caused by false triggering of sensors. This feature Electronics are very important, since the power stress can fluctuate within 30% and more from the nominal.
  2. A minimum of possible blockages and malfunctions of wall gas boilers are reduced, caused by non-standard water pressure. The design is thought out so that it works confidently even when the indicator drops to 0.1 bar. This makes the device perfect for installation on the upper floors of apartment buildings, where the water pressure drops in the cold water circuit periodically occurs.
  3. Connected non-standard indicators of the gas pressure of the malfunction with a gas boiler device is successfully neutralized. Nozzles, protection systems, ensuring such that the unit works confidently even with a critical pressure drop of up to 4 mbar. This is an extremely low indicator that cannot be used by most modern electronic control systems.
  4. According to the instructions of the Gas Wall Copper Navien, the heating system will be prevented even if the gas supply is discontinued. To prevent emergency regime when the coolant temperature drops below 5 degrees Celsius and the impossibility of hilt burner, the built-in pump begins forced continuous circulation of water in the system, which does not allow its freezing.
  5. Since all systems of this brand are equipped with a double heat exchanger for separate heating. hot water And heating coolant, you can flexibly configure priority modes. It is possible to even set the conditions for preheating water for hot water supply. Electronics allows very convenient settings, and the instruction manual of the two-king gas boiler Navain will clearly show the user how to do it.

The equipment of this company provides for the advanced management principle. The remote from which the parameters and modes are configured - remote. It is also used as an external thermostat sensor, to measure and maintain the temperature indoor.

The engineering features of the products of Navien, which set the high parameters of its quality, and also confirm the opinion of some experts on the unlimited work period of boilers include the following facts.

  1. Separate heat exchangers out of stainless steelnot subject to corrosive providing high heat transfer.
  2. Automatic pressure maintenance system in the heating system. If the water is exceeded, water is merged, with an insufficient indicator, it gets from the cold water supply system, according to the instructions for the gas boiler, the concrete model. To control the pressure is a pressure gauge.
  3. The incoming water passes through the filter and is effectively cleaned.
  4. Personal drain channels are provided to get rid of water in coils, if it is impossible to carry out forced circulation.
  5. Electronics controls the supply of gas so exactly that the water temperature in the system can be set up to 0.1 ° C.
  6. In summer, you can change the mode of operation to ensure only the need for. It is easy to do both according to the instructions for floor gas boilers Navien and the documentation for other models.
  7. To save fuel, there is a customizable "out of the house" mode when the boiler can minimally maintain the room temperature.

Key disadvantages of systems


With all the functionality, stuffing with electronics, convenience and ignoring difficult working conditions, gas boilers Navain is not devoid of some flaws. Users often encounter cases when the device refuses to work, because the electronics signals critical error. This occurs for various reasons, including those associated with the high sensor sensitivity. Consider two most frequently repetitive errors.
Smoke removal
During problems with the removal of combustion products, a malfunction code of 10 gas boilers is arising. According to the user manual, the reasons for such a signal may be several:

  • failure of the turbine (engine or due to the problem in the uncut mechanism);
  • invalid attachment of pressure sensor tubes;
  • clogging of the chimney;
  • the large length of the pipe leading (the maximum length is specified in the instructions);
  • gust winds.

Most often, users have the following picture:

  • chimney permissible length;
  • not clogged;
  • pressure sensors tubes are in order, since the intervention in the design was not performed.

Many are upset, thinking that the problems in the work of the turbine. However, oddly enough, most often the reason is strong wind on the street. As the manufacturer declares, it is recommended to mount boilers with the condition of the chimney to the lever side of the building.

As a result of the fact that different time The wind blows in different ways, so the heating systems can operate on a signal signal, signaling 10. One of the solution methods is the alteration of chimney.

Since it will not work promptly to do it, you can open the device body and disconnect the air supply nozzle. The turbine will start selecting it from the room, the boiler will work. Decision temporary, but works.

Flame Failure Failure

A malfunction error 03 gas boilers is caused by poor fuel quality. Mechanics of the emergence of the problem is:

  • gas is served;
  • the pressure in the highway is sufficient so that the sensors do not raise the alarm;
  • in progress, there is no sufficient heating of the sensor electrode, since the distribution of flame temperature zones is impaired.

The problem is solved solely by the method of selection. The first thing to be verified is the purity of gas supply nozzles. If they are clean and fuel supplied, the second stage should be selected the position of the sensor electrode. It must be in the hot flame phase so that the signal is correctly identified.

This error is the rarity where gas is served good qualitySince this company's products are perfectly coping with any pressure indicators. But in the territory of the regions with low quality gas preparation, a malfunction with code 03 is quite common. Sometimes you have to change the position of the sensor electrode several times in one heating season.

In general, the manufacturer's heating system is quite cheap, technologically equipped solution, ideal in order to cope with non-standard working conditions. They can be extremely useful because very reliable and durable. All components are manufactured by Korea and Japan enterprises, the quality assembly, the boilers meet all international standards.

Like any complex device, boilers are not devoid of problems. However, in most cases the user does not face trouble during the operation of the equipment from this manufacturer.

If we consider the turnover of the heating devices in the domestic market, then it can be noted that consumers prefer European techniques. However, Korean is a mounted cauldron, the price of which is lower than Western counterparts, takes up top positions among other heating devices. This is due to the durability of the products and the presence of warranty service. Also read: "Gas boiler from Beretta - simple, reliable and functional"

What are the walls of Navien wall boilers

Made in Korea.

The company from Asia loudly declared itself and its products, because the choice of European brands has declined. Korean company products can compete with gas aggregates of any european manufacturer. Therefore, the NaVien gas boiler is only positive users.

One of the most popular and reliable is the two-circuit boiler attachment of the ACE lineup. Such devices may have an open or closed combustion chamber. The functional component of the device is distinguished by durability, which users and specialists mark. At the same time, the price of the mounted boiler is much lower than equipped, which offers European brands.

The line is represented by several devices:

  • Navien ACE-20K;
  • Navien Ace Turbo.

The last model is worth considering first. This boiler is presented in two variations - Korea and Coaxial. Wall equipment for heating system has a rated power of 13-40 kW. Wherein this indicator It does not depend on the modification. Gas boiler Navien, according to reviews, ideal for use in the climatic conditions of our country.

The equipment is characterized by the ability to work in difficult operating conditions: pressure drops in the gas pipeline, with voltage drops in the power supply network. Even being not included for a long time, such a boiler will start without problems and perform its functions for 100%.

Features Navien Ace Turbo

Compact placement of boiler elements.

The wall double-circuit boiler is characterized as follows:

  • application for water heating and heating residential buildings;
  • the composition of the equipment is a steel heat exchanger, coated with anticorrosive, which significantly reduces the cost of equipment in comparison with boilers, equipped with copper heat exchangers;
  • nAVIEN ACE gas boiler (instruction manual is attached to each model) is easy to use;

Wall-mounted equipment has "brains". This means that the unit ensures that the coolant does not freeze in the pipelines of the heating system. Automation is triggered in two cases. The first is when the water temperature drops to 10 degrees. This time turns on. The second situation occurs at a coolant temperature of less than 6 ° C. In this case, the gas burner is included, heating the coolant to 21 degrees.

The double-circuit boiler Navien Ace Turbo and the 16K model will operate when the power supply voltage is reduced to 30%. The Navien ACE 16K instructions also indicate that the boiler will not turn off when the water pressure is 0.1 bar.

Products Navien reviews have positive. This is due to a long period of use, high efficiency of the unit. The equipment is characterized by high fuel and electricity savings. This contributes to the availability of turbocharging and the APS sensor, which monitors air pressure.

Characteristics Navien Ace ATMO and NAVIEN ACE 20K

In the boiler installed uninterrupted voltage.

Among the company's products there are double-circuit boilers with turbocharging and without it. The latter belong to the ACE ATMO line. They possess the same functions as the equipment with turbocharging. Korean gas boilers Navien Ace reviews have a large positive, which once again testifies to product quality.

Such an aggregate is equipped with the same chip providing uninterrupted work With voltage jumps in the power supply network as the above-described models. Distinctive feature Devices lies in the absence of turbocharging, thereby ensuring a silent job.

NAVIEN ACE 20K, like other Korean brand units, is fully adapted under climatic conditions Russia. The device is safely operating at low gas pressure and water, which allows them to be used in multi-storey residential buildings. This expands their scope. The organization of removal of combustion products can be carried out in different ways:

  • by setting the horizontal (usual) chimney;
  • for separate system removing smoke;
  • by mounting in a vertical position.

It is important to note that some variations of equipment from Navine support remote control using a phone or tablet.

Navien is a major South Korean corporation, which produces universal, high-quality and reliable gas boilers. Navien devices are distinguished by reliability in work, practicality and functionality. These devices have an open or closed combustion chamber, their functional part is distinguished by durability. At the same time, their cost is lower, if compared with European counterparts.

Navien presents a universal water heating system

NAVIEN ACE gas boilers are not afraid of low gas and water pressure, they are not afraid of voltage drops on the network. The operation of gas boilers is characterized by a long period of operation and cost-effective gas consumption. All NAVIEN gas devices comply with the standards and norms of the Russian Federation and have relevant certificates.

Stability of freezing protection system

If the room temperature drops, then the automatic protection system is triggered From freezing. When lowering the water temperature of heating more than 10 degrees Celsius, automatic launch circulating pumpAs a result, constant circulation of the coolant in the heating system is ensured. If the water temperature of heating drops to 6 degrees Celsius, the burner is automatic and the coolant is heated to 21 degrees Celsius.

Safety of work with frequent voltage drops on the network

According to the instructions, the voltage can vary within ± 30 percent, due to the operation on the microprocessor of the SWITCHED - MODE POWER SUPPLY (SMPS) protective chip. Wherein the work of the boiler does not stopthat extends its period of operation and prevent breakdowns.

The conditions of operation of heating and hot water:

  • under the condition of low input pressure in the gas pipeline system - the stable and safe operation of the NAVIEN ACE gas boiler is possible at a gas pressure of four mbar (40 millimeters of water column);
  • under the condition of low incoming water pressure in the water supply - the stable operation of the NAVIEN ACE gas boiler is possible under the condition of the incoming water pressure to the value of 0.3 bar, which allows you to apply it gas device in houseswhere weak water pressure in the water supply system, including where the frequent pressure drops in the water supply system.

Rational design

Navien gas boilers are distinguished by small sizes and low weight, it is convenient to transport them, they are easy to install and is the possibility of rational use of the room area. For the convenience of installation, connecting tubes are located on both sides of the device, due to which the blockage and installation of the NAVIEN ACE gas boiler is largely simplified.

Preliminary fuel preheating (KR series)

With low temperature indicators, the viscosity of the fuel increases, as a result of which the effect of paraffinization occurs that significantly worsens the flammability of diesel fuel And the operation of the gas boiler Navain becomes unstable. Such a feature of the work is relevant for regions with a harsh climate, so the arctic and winter diesel fuel has been created for these conditions.

Gas devices Navien work on any diesel fuel russian production However, the cost of winter or arctic diesel fuel is much higher than the summer, and the use of summer fuel is not possible at low temperature values \u200b\u200bwithout preheating it.

The heating element, which is built into the NaVien gas unit burner before applying fuel to the nozzle, pre-heats it, resulting in high-quality spraying of fuel and uninterrupted flammability. Due to preheating in the gas boilers, Navien Ace has the possibility of using inexpensive summer diesel fuelWhat leads to significant savings.

Design

1. The heat exchanger is made of stainless steel

For the production of heat exchanger, stainless steel is used, so it is not subject to corrosionthat significantly prolongs the service life of the Navien Ace boiler.

2. Modern diesel burner

Due to modern effective diesel burner Supported low-noise stable work with minimal cost Fuel. According to the instructions the burner can work with any diesel fuel, taking into account all types of fuel production of the Russian Federation.

3. Fuel filter with interchangeable cartridges

The fuel supply system is equipped with a filter for cleaning from unwanted impurities, as a result of which the stable operation of the NAVIEN ACE gas boiler is disturbed. An additional interchangeable cartridges includes the set with the device.

4. Russified control panel

Using a remote fully Russified control panel equipped with a liquid crystal digital display, created the possibility of economical fuel consumption and reduce heating costs, as well as permanent maintenance of comfortable room temperature due to the sensor room temperatureBuilt into the control panel.

Safety technique

Safety Instructions are provided in each user manual for the Navien boiler, where all is important information To safely use the device. Failure to follow any instructions may result in death, serious injuries and damage to the product being operated.

On the Navien Ace boiler or in the instructions, the following abbreviations and signs can meet:

  • OV - heating water;
  • DHW - hot water supply;
  • Hydz - cold water supply;
  • triangle having an exclamation mark - a threat to life if the safety rules are not followed;
  • circle crossed - prohibited actions;
  • a circle having an exclamation mark - mandatory actions.

Navien gas boiler is excellent alternative expensive analogues European production, not inferior to them in quality and durability. The main advantage over other European devices is the presence of warranty service.

Updated:

2016-09-16

The boiler Navain is a high-quality South Korean heating equipment. The company is engaged in the production of modern gas boilers. This product quickly gained confidence from consumers, has become a regular participant in the domestic market, significantly expanding the possibilities of buyers to choose the perfect boiler.

Photo of the boiler Navain

Wall and floor boilers from Naven have a number of features that allocate them against the background of competitors.

  1. The system for operation during discharges in the power grid. Navien gas boiler models are distinguished by the presence of a technical filling that allows the equipment to operate even with differentials in the power grid reaching 30 percent. This is a guarantee that your wall boilers Do not require repair, if there are problems with electricity in the house. And such situations are not uncommon for us.
  2. The ability to operate at low pressure of the plumbing system. Problems with pressure in the plumbing happening less often, but even when they occur, the boiler will function normally, to provide warmth and the whole house.
  3. Not one heat exchanger, and two. All wall-mounted Navien boilers are not one heat exchanger, but a pair. Each heat exchanger is made of stainless steel, which is characterized by reliability, efficiency and resistance to corrosion. Such a design with a pair of heat exchangers increases the stability of the boiler to water pollution, scale, provides affordable repair. The price of the firm boilers themselves is attractive enough - from 30 thousand rubles. There are more expensive, productive models that are capable of providing warmth impressive in the area of \u200b\u200bthe room.
  4. Turbocharddv. Each outdoor and wall-mounted boiler of the South Korean company Navien is equipped with turbocharging - air supply system. It increases the coefficient useful action boiler device. Air supply pressure is regulated by automatic. As a result, at lower fuel expenditures, the best home heating is provided.

Benefits

With the features of the design of boilers, I talked with you. These are four objective reasons to pay close attention to such models as the Navien Ace and Deluxe, Prime boiler.

If you put the boilers Navien in one row with competitors presented in the domestic market in about the same price category, the South Korean manufacturer will demonstrate whole line Obvious advantages:

  • High level of quality and reliability of automation. Errors for such boilers are rare and can only be caused by failures in systems or incorrect management from the user. But if errors occur on Deluxe, Prime or ACE models, it is easy to eliminate them. Most of the work takes automation. Errors are easily read, the reasons for their occurrence according to the manufacturer's instructions are determined;
  • The presence of SMPT security chips. With their help, boiler gas equipment works perfectly under the conditions of unstable electrical network. All you know how often problems with power grid in our homes arise. Many boilers are not able to cope with such oscillations, constantly give mistakes and fail. With NaVien boilers, such situations minimize;
  • The adaption of the boilers is Navien under the conditions of operation in domestic realities. We are talking about unstable pressure in the gas pipeline and problems with water pressure in the water supply. The boiler of the company NaVien models Prime, Deluxe or Ace perfectly copble with similar conditions when the gas pressure drops to 4 mbar, and water to 0.1 mbar;
  • Real Korean assembly. Unlike a variety of products with European or other designations on hulls, Navien boilers are really going to Korea, and not somewhere in China in order to reduce the cost of assembly. It is no secret that many foreign companies establish production in the subnet. And give the equipment for the European, for example;
  • Remote control. Navien boilers are completed with special convenient consoles, with which the user can change the modes of operation of their boiler equipment at a distance.

Range

The range of the South Korean company Navien is constantly expanding, which allows customers to acquire gas boilers optimally suitable for all parameters.

Therefore, tell about all representatives model Row It is impossible. Instead, we will look at the equipment of Navien, which can be divided into three large categories.

  1. Wall-mounted models. Wall boilers have a double heat exchanger, marked as Ace, Deluxe. Deluxe is two-circuit models that have a wide range of capacity up to 13 to 40 kW. All boilers series Deluxe turbine. Deluxe turbocharged equipment may have a coaxial or separate chimney. In addition to Deluxe, a series of wall-mounted ACE models is in great demand. The ACE series is divided by Turbo and Atmo. The difference between them lies in the fact that the turbo is fully adapted to operate under the conditions of nonstal supply of gas and electricity to the boiler. Additional advantage ASE Turbo is protection against freezing and turbocharging burner. If we talk about atmos, then this is a classic gas boiler, perfectly providing a private house heating. Atmo has everything strengths Turbo, except turbocharging burner.
  2. Navien floor boilers. If the wall models for one or another do not suit you, the excellent reviews deserved outdoor models. They are used for heating and hot water supply of private houses. The distinguishing features of the floor models of boilers, the Naven should include their compact sizes, ease of operation and convenient installation. Each boiler is attached, according to which even a newcomer can be installed in such affairs. Wall-mounted models set somewhat simpler, although there are no problems with them. The double heat exchanger significantly increases the efficiency of heat generation in the gas boiler.
  3. Condensation. Deluxe, ACE and other models of the company Navien not so long ago received a serious competitor in the face of condensing South Korean boilers. They are marked with NCN. Their distinctive feature is an increased power, the range of which is 19.6-37.9 kW. These boilers effectively use fuel, spending less than its quantity, but providing more high-quality heating. The coefficient of efficiency in the boilers of the condensation type reaches 108 percent. This became possible through the use of heat, which is allocated during steam condensation. Thus, consumers save money for gas pay, but more efficiently heated their own home. The heat exchanger here is somewhat different. Its design is unique, it is distinguished by the presence of a system of pre-creation of a combustible mixture. The burners are necessarily modulating, the range of operation is affected.

Choosing boilers from the company Navien from Deluxe series, Ace or other assortment, you buy quality and reliability. This is one of the few cases when the manufacturer does not require more only for the brand. The high level of Navien boilers is no doubt.

Hinged gas boiler " NAVIEN DELUXE 24K."He is a hit selling in Russia recent years. And this is quite explained, the optimal ratio of "price-quality", good specifications And reviews made this model very popular among domestic buyers.

Today we will focus in detail on the "Navien Deluxe 24K Coaxial" model with a closed combustion chamber and a capacity of 24 kW, we will analyze the instruction manual (passport), errors arising from possible gas boiler faults under the appropriate codes, methods to eliminate and repair, as well as basic functions and properties.

Gas boiler Navien Deluxe 24k: constructive features Models

On the russian market The South Korean company supplies several modifications of wall (mounted) two-circuit gas boilers with a closed combustion chamber of the Deluxe series. The buyer has pretty wide selection Wall turbocharged apparatus at a price of 27,000-35,000 rubles, and this:

- NAVIEN DELUXE COAXIAL 24K;

- Navien Deluxe 24k;

- NAVIEN DELUXE PLUS 24K;

Navien Deluxe 24K Coaxial and Deluxe Plus 24K


The largest popularity of buyers has gained the model "NAVIEN DELUXE COAXIAL". Unlike the "NAVIEN DELUXE 24K" and "NAVIEN DELUXE PLUS 24K" models, it is produced under the horizontal 60/100 "pipe in the pipe".

Navien Deluxe 24K and Navien Deluxe 24K and Navien Deluxe 24K COAXIAL have a remote control unit in their configuration, which is at the same time and a room thermostat for the boiler.

On the Navien Deluxe Plus series devices, the operation of the boiler is carried out using the control panel built on on the front of the case, and the chimney device has two nozzles, as well as on the Navien Deluxe 24K series, or for separate chimney (75 mm and 70 mm), or for the cumbersome Korean version of the chimney of stainless steel with an output through the side wall or through the wall on which the boiler is installed.

Copper Navain Deluxe 24K: instructions, components, spare parts

Gas boiler "Navien Deluxe 24K" consists of the main elements: two stainless steel heat exchanger for heating and DHW, expansion tank, circulating pump, gas and three-way valve to switch the operation modes of the contours, as well as security groups.

In addition, a set of other elements that provide uninterrupted operation are installed in the boiler. heating apparatus and security.

We look at the device diagram and connecting the gas boiler "Navien Deluxe 24 K Coaxial":

Navien Deluxe 24K Gas Copper: Instructions

1 - chimney plug;

2 - Heating Contour temperature sensor;

3 - Sensor of the duct of the heating circuit;

4 - flat expansion tank;

5 — gas-burner boiler;

6 - pressure gauge for pressure control;

7 - airlightener;

8 - three-way valve;

9 - circulating pump;

10 - Differential relay;

11 is a straight line of heating;

12 - plums;

13 - the filter of the heating system;
14 - reverse heating line;
15 - safety valve;
16 - the output of the DHW circuit;
17 - the input of the DHW circuit;
18 - connecting the gas hose;
19 - gas valve;
20 - GVS duct sensor;
21 - control unit ("brains");
22 - secondary heat exchanger for DHW;
23 - fan;
24 - Gas burner nozzle collector;
25 - ignition transformer;
26 - ionization and ignition electrodes;
27 - closed combustion chamber;
28 - primary heat exchanger for heating;
29 - Collector of combustion products.

Possible malfunctions of the Navien Deluxe boiler and the methods of their facilities with their own hands

When operating a wall gas boiler, Navien, like any other modern equipmentyou may encounter possible malfunctions, failures in the work of the device. When the boiler breaks, an error on a specific code appears on the control panel display.

You can try to eliminate a malfunction and independently without causing the home of specialists. To do this, we will analyze the most common mistakes that occur when the Navien Deluxe heating apparatus is operational.

The boiler warm water.

The likelihood is high that the heating system is "delivered." In this case, it is necessary to remove the accumulated air from the system or it will be necessary to replace the automatic air vent. It is also possible to clog the filter heating system, Clean or replace it with a new one.

Error 02..

This error code signals that there is an insufficient amount in the heating system. Or incorrectly filled with a heating system, or in some kind of water flowing. It is necessary to add water to the heating circuit, fill the system.

Error 03..

If an error is highlighted on the screen at code 03 - it tells us that there is no ignition in the boiler due to the lack of gas supply to the gas burner. Check if the gas valve is open on the pipe.

Error 04.. False flame.

Error 05.. Defective temperature sensor heating circuit.

Error 07.. Fault of the hot water circuit temperature sensor.

Error 09..

This error code signals us that the fan is faulty (turbine), it may be necessary to replace it.

Errors of boiler Navain


Error 10..

Insufficient thrust in the combustion product removal system. Diagnostics of smoke removal system is needed to identify the cause of failures in its operation.

Error 12.. There is no flame.

Error 13.. It is possible to replace the duct sensor for the heating circuit.

Error 15..

This error says that the Electronic Control Panel is faulty in the Cavane Deluxe Boiler.
It is likely that it overwhelmed from the voltage jump in the power grid or for other reasons, and it will be necessary to buy a new one.

Error 16.. The main heat exchanger of the heating circuit overheats.

Error 17.. Malfunction of the DIP switch electronic board.

Error 27.. Faulty air pressure sensor.

Error 46.. The sensor overheating the primary heat exchanger heating has failed.

Error 57.. Problems with connecting air pressure sensor hose.

Error 94.. Machines for the auxiliary memory of the boiler board.

Naven Deluxe: Technical Specifications of the Gas Boiler

The main characteristics, parameters, the size of the gas boiler "Naven Deluxe" and gas consumption are presented in the table below.

Specifications Navain Deluxe


We disassemble the gas boiler NAVIEN DELUXE 24K.: Instructions, specifications, prices, considered the main faults of the boilers of Navien and errors when working.

Despite various customer reviews, the products of the South Korean company are an excellent "price-quality" ratio. The pros also include inexpensive spare parts and a wide network of service centers in the country. We watch the video.

Autonomous heating and hot water supply turns a private house to a comfortable home, providing considerable savings and independent of the appetizers of resource providers.

Installing your own boiler allows you to independently adjust the heating mode, based on the need and climatic conditions, and not an average annual charter supply schedule.

The choice of equipment in the trading network is extensive, but it is quite difficult to find the most successful option.

The cost of European boiler models is too high, the quality of domestic samples often leaves much to be desired.

Consider one of the most successful optionscombining available cost and high quality.

Gas navien boilers They are products of the South Korean industrial concern Kyungdong Navien.

Firm specializes in production and design heating equipmentworking on different types Fuel - liquid, solid, gas and electricity.

Navien Deluxe is a series of two-circuit wall-mounted gas boilers, which has replaced with the production of the Navien Ace family.

The design and set of functions have practically not changed, although some points are improved and supplemented.

The aggregates perform the flow of the coolant (s) into the heating system and simultaneously provide a dwelling hot water (DHW).

Korean developments were carried out taking into account Russian conditions and specialized in working with unstable parameters in all directions - gas pressure and water, electricity fluctuations. The equipment fully complies with the standards and standards in force in the territory of the Russian Federation.

Naven boilers are equipped with a special device compensating for voltage fluctuations in the network up to 30%.

What models come to her

The Deluxe series includes the following boiler models:

  • Deluxe.
  • Deluxe Plus.
  • Deluxe Coaxial.
  • Deluxe ATMO.

Three first models are practically no different from each other, having only minor discrepancies in the design of the chimney or the gas supply value.

The model atmo is the boilers with an open combustion chamber, which differ directly from the room directly from the room.

All types of boilers are produced in different options By power:

  • 13K (kW).
  • 16K (kW).
  • 20K (kW).
  • 24K (kW).
  • 30K (kW).
  • 35K (kW).
  • 40K (kW).

Some models are created on the basis of one size with a software limited functionality.

Thus, the boilers with a capacity of 24 and 16 kW are an identical design, but 16 kW models have a slightly reduced power. This gives the aggregates a noticeable power supply, allowing you to freely overcome the load changes and external influences.

Specifications

Consider the technical characteristics of the boilers Navain Deluxe:

Some changes or additions are possible in the values \u200b\u200bof the parameters of boilers arising from the improvement of the design by the manufacturer.

Advantages and disadvantages

To the advantages of Navien Deluxe boilers:

  • The ability to ensure the supply of DHW along with the organization of housing heating.
  • Environmental safety equipment.
  • Advancement to Russian technological and climatic conditions.
  • Simple and reliable control, presence of a remote control.
  • The presence of a self-diagnostic system by means of a group of sensors performing monitoring of all systems and assemblies of the unit.

The disadvantages of the aggregates are:

  • Dependence on the presence of power supply, gas and water.
  • High noise.
  • The possibility of using only full-time components.

All features of the Navien Deluxe boilers are essentially specific signs of the design and may well be compensated proper operation and maintenance.

Device

The Navien gas-rounded boiler produces heating of the coolant and ensures its circulation in the system.

A gas burner, combined with a primary tubular heat exchanger, heats the stream of OS, which passes at the output through a three-way crane.

To obtain a given temperature, a mixing of a certain amount of cooled repetition is mixed, after which the coolant is sent to the system.

The combustion mode is regulated by the feed fresh airwhich fan performs.

Hot water heating produces a secondary heat exchanger (plate). The operation of all devices is controlled by the sensor system signaling on the control board on the appearance of certain problems.

Where used

Gas double-circuit boilers Navien Deluxe are designed for heating and gWS feed in private houses.

The boiler power corresponds to the serviced area, which makes it easier to choose the desired device.

For industrial heating or public buildings The use of the NAVIEN Deluxe series is not recommended, since the specific capabilities of the equipment in such conditions will not be disclosed in proper extent.

Often, such equipment is installed in apartments if their size allows you to install such power equipment.

What is included in the package

In the package of boilers, Navain includes:

  • Primary and secondary heat exchangers.
  • Expansion tank for 8 liters.
  • Gas board closed or open type.
  • Three-way crane with an electric motor.
  • Fan for the organization of turbocharging.
  • Circulation pump.
  • Sensor system connected to the control board.
  • Built-in voltage stabilizer.
  • Remote remote.
  • Case with external connecting nozzles.

Depending on the model and the series, some additional nodes may be present. Constant development and improvement of the design contributes to the complication of the old and emergence of new elements.

User's manual

The work of Navien boilers passes in automatic mode and practically does not need human participation.

The only thing that is required from the owner is the installation of a comfortable temperature. If liquefied gas is used as fuel, it is necessary to monitor the timely replacement of cylinders.

Opportunity long work Without specialized service checks, it is a feature of equipment from Navien, which is convenient for users and removes the care of the state of the unit.

When any faults appear on the display, the code of the corresponding error appears, the water pressure shows a pressure gauge that allows you to detect the leakage of the system.

The owner may require the acquisition and installation of a special filter or water softener, which will allow to extend the life to most boiler knots - heat exchanger, pump or three-way crane. If the water supply is made from its own well, the installation of the softener becomes a necessity.

Setting up the device with your own hands

To configure the boiler, set the debug mode. Then you should adjust the gas pressure limits to a minimum and maximum.

From the circulation pump, it is necessary to release air, unscrew the plug. It is carried out after a set of pressure when circulating.

Setting the boiler operation is produced using a dip switch.

  • You can turn on the automatic output of air using the dip switch No. 1, which will run the circulation for 2 hours and gradually remove the air automatically.
  • Turning on the switch number 2 translates the operation of the system to the maximum power at which you can adjust the maximum gas pressure.
  • When switching on the switch No. 3, the boiler is translated to the forced mode of operation at a minimum power at which the minimum gas pressure is configured.

All shifts must be performed when the power is turned off.

The boiler setting should be entrusted to those skilled in the service center. Self-execution work is possible only when urgent need and the absence of a warranty agreement.

Major malfunctions and solutions

The faults appear on the display as a numeric code. Each of them corresponds to a certain error, i.e. Signal from a specific sensor to refuse the corresponding node.

Perhaps the presence of additional codes with which you need to carefully read in the user manual.

Ownership reviews

The most reliable and unbiased information about the properties of the boilers of the Korean company can be obtained only from people using these aggregates for heating and supplying DHW in their homes.

Consider some of the reviews.:

((ReviewSoverall)) / 5 Rating owners (7 votes)

Your opinion

0"> Sort by: The latest highest score is the most useful worst score

Be the first one to leave a review.

If we consider the turnover of the heating devices in the domestic market, then it can be noted that consumers prefer European techniques. However, Korean is a mounted cauldron, the price of which is lower than Western counterparts, takes up top positions among other heating devices. This is due to the durability of the products and the presence of warranty service. Also read: "Gas boiler from Beretta - simple, reliable and functional"

What are the walls of Navien wall boilers

Made in Korea.

The company from Asia loudly declared itself and its products, because the choice of European brands has declined. The Korean firm products can compete with gas aggregates of any European manufacturer. Therefore, the NaVien gas boiler is only positive users.

One of the most popular and reliable is the two-circuit boiler attachment of the ACE lineup. Such devices may have an open or closed combustion chamber. The functional component of the device is distinguished by durability, which users and specialists mark. At the same time, the price of the mounted boiler is much lower than equipped, which offers European brands.

The line is represented by several devices:

  • Navien Ace ATMO;
  • Navien ACE-20K;
  • Navien Ace Turbo.

The last model is worth considering first. This boiler is presented in two variations - Korea and Coaxial. Wall equipment for heating system has a rated power of 13-40 kW. In this case, this indicator does not depend on the modification. Gas boiler Navien, according to reviews, ideal for use in the climatic conditions of our country.

The equipment is characterized by the ability to work in difficult operating conditions: pressure drops in the gas pipeline, with voltage drops in the power supply network. Even being not included for a long time, such a boiler will start without problems and perform its functions for 100%.

Features Navien Ace Turbo

Compact placement of boiler elements.

The wall double-circuit boiler is characterized as follows:

  • application for water heating and heating residential buildings;
  • the composition of the equipment is a steel heat exchanger, coated with anticorrosive, which significantly reduces the cost of equipment in comparison with boilers, equipped with copper heat exchangers;
  • nAVIEN ACE gas boiler (instruction manual is attached to each model) is easy to use;

Wall-mounted equipment has "brains". This means that the unit ensures that the coolant does not freeze in the pipelines of the heating system. Automation is triggered in two cases. The first is when the water temperature drops to 10 degrees. This time turns on. The second situation occurs at a coolant temperature of less than 6 ° C. In this case, the gas burner is included, heating the coolant to 21 degrees.

The double-circuit boiler Navien Ace Turbo and the 16K model will operate when the power supply voltage is reduced to 30%. The Navien ACE 16K instructions also indicate that the boiler will not turn off when the water pressure is 0.1 bar.

Products Navien reviews have positive. This is due to a long period of use, high efficiency of the unit. The equipment is characterized by high fuel and electricity savings. This contributes to the availability of turbocharging and the APS sensor, which monitors air pressure.

Characteristics Navien Ace ATMO and NAVIEN ACE 20K

In the boiler installed uninterrupted voltage.

Among the company's products there are double-circuit boilers with turbocharging and without it. The latter belong to the ACE ATMO line. They possess the same functions as the equipment with turbocharging. Korean gas boilers Navien Ace reviews have a large positive, which once again testifies to product quality.

Such an aggregate is equipped with the same chip that is uninterrupted with the voltage jumps in the power supply network as the above-described models. A distinctive feature of the device is the absence of turbocharging, thereby ensuring a silent job.

NAVIEN ACE 20K, like other Korean brand units, is fully adapted for the climatic conditions of Russia. The device is safely operating at low gas pressure and water, which allows them to be used in multi-storey residential buildings. This expands their scope. The organization of removal of combustion products can be carried out in different ways:

  • by setting the horizontal (usual) chimney;
  • with a separate system for removing smoke;
  • by mounting in a vertical position.

It is important to note that some variations of equipment from Navine support remote control using a phone or tablet.