Copper thermal engineer TT100 The number of smokery pipes. Water heating three-way boilers entrodros thermal engineer TT100

Boilers TT100 thermotechnic Produced serial. The power of the boilers produced by Entropros varies from 1000 kW to 15000 kW. All TT100 series boilers have the heat-tube design of the furnace and gas ducts belong to the boilers of the heat-tube type and are designed to install in boilers with a maximum coolant temperature to 115 degrees C and with a working pressure of up to 0.6 MPa. Preferred spheres of applying boilers TT100 TT100 are boiler industrial purpose. These include large boiler houses of housing and communal services, boiler various productionsobjects and boilers, which supply thermal energy technological equipment of various industries. Boilers TT100 thermotechnic Used for both heating systems and hot water systems (DHW).
The Entropros TT100 boilers are installed for the upgrade burners of the fan type, which provide automatic feed, ignition and fuel combustion. To control the flame burner in the front plate of the boiler there is an observation eye that allows you to visually monitor the combustion process in the boiler firebox. Coppers Entropros TT100 TT100 Can be installed in boiler house any power. This is due to a wide range of boilers, which produces Entoros company.

In our company, you can purchase water-heating steel fire-tube boilers Lavart brand produced by the Omsk plant of innovative technologies. Go to page Boiler equipment Lavart.

TT100 series boiler models:

Boilers thermal engineer TT100-1000 with a capacity of 1000 kW

Water heating boilers of winter-tube type. Water consumption - 57 m³ / h. Water boiler volume is 1.76 m³. This boiler is the most small power from the TT100 series boilers. Maximum temperature up to 115 ºC.

Boilers TT100-1500 TT100-1500 with a capacity of 1500 kW

Water steel gas-tube boilers. Water consumption - 86 m³ / h. Water boiler volume is 1.86 m³. The boiler is serially and is one of the most popular Entropros boilers. Maximum temperature up to 115 ºC.

Boilers thermotechik TT100-2000 with a capacity of 2000 kW

Heating boilers gas-pipe-smoke-type type. Water consumption - 115 m³ / h. Water volume of the boiler is 2.8 m³. Boilers are manufactured and delivered under the order. Maximum temperature up to 115 ºC.

Boilers thermal engineer TT100-2500 with a capacity of 2500 kW

Steel three-way boilers. Water consumption - 143 m³ / h. Water volume of the boiler is 3 m³. Boilers with a maximum operating capacity up to 2.5 MW. Maximum temperature up to 115 ºC.

Boilers thermal engineer TT100-3000 with a capacity of 3000 kW

Steel boilers. Water consumption - 172 m³ / h. Water volume of the boiler is 4.1 m³. Boilers with a maximum operating capacity of up to 3 MW and maximum excess water pressure up to 0.6 MPa. Maximum coolant temperature up to 115 ºC.

Boilers thermotechik TT100-3500 with a capacity of 3500 kW

Russian rigged boilers. Water consumption - 201 m³ / h. Water volume of the boiler is 4.6 m³. High quality heating boilers. High quality design. Maximum coolant temperature up to 115 ºC.

Boilers thermal engineer TT100-4200 with a capacity of 4200 kW

High power boilers, up to 4.2 MW. Water consumption - 241 m³ / h. Water volume of the boiler is 5.4 m³. Steel water boilers Wheel-tube design. Maximum coolant temperature up to 115 ºC.

Boilers TT100-5000 TT100-5000 with a capacity of 5000 kW

Boilers Entropros thermal engineering, industrial purpose. Water consumption - 287 m³ / h. Water volume of the boiler is 6.4 m³. Water Heat heating boilers With high efficiency. Maximum coolant temperature up to 115 ºC.

Boilers TT100-6500 TT100-6500 with a capacity of 6500 kW

Boilers TT100 high power, manufactured by Entrodos company. Water consumption - 384 m³ / h. Water boiler volume is 7.4 m³. Water heating boilers with high efficiency. Maximum permissible temperature The coolant at the outlet of the boiler up to 115 ºC.

Boilers TT100-8000 TT100-8000 with a capacity of 8000 kW

Boilers TT100 series, manufactured by Entrodos, with a maximum power of 8 MW. Water consumption - 474 m³ / h. Water boiler volume is 9.6 m³. Water heating boilers with high efficiency. The maximum allowable water temperature at the outlet of the boiler to 115 ºC.
Read more ⇒

Boilers thermotechik TT100-10000 with a capacity of 10,000 kW

The boilers of the TT100 series, Entoros firms, with a maximum power of 10 MW. Water consumption - 591 m³ / h. Water boiler volume is 12.1 m³. Water heating boilers with high efficiency. The maximum water temperature at the outlet of the boiler to 115 ºC.
Read more ⇒

Boilers thermal engineer TT100-12000 with a capacity of 12000 kW

TT100 boilers, with a maximum power of 12 MW. Water consumption - 688 m³ / h. Water boiler volume is 15.5 m³. Water heating boilers with high efficiency. The maximum water temperature at the outlet of the boiler to 115 ºC.
Read more ⇒

Boilers TT100-15000 TT100-15000 with a capacity of 15000 kW

Boilers TT100, with a maximum power up to 15 MW. Water consumption - 888 m³ / h. Water volume of the boiler is 20 m³. Industrial water heating boilers with high efficiency. The maximum water temperature at the outlet of the boiler to 115 ºC.
Read more ⇒

Everything boilers TT100 thermotechnic Have a cylindrical shape of a boiler, combustion chambers and gas ducts. For the manufacture of the boiler TT100, high-quality steel is used, which maintains temperature loads on the inner walls of the boiler. The design of the TT100 boiler, due to the fully washed wall of the boiler and the torusferic bottom, provides high heat exchange intensity. The front wall of the boiler is installed on the hinges that are installed on the right or left side of the boiler and allow you to open the door with the burner. This greatly facilitates both the scheduled maintenance of the TT100 boiler and the maintenance of the burner. The design of the boiler provides for the possibility of inspection of the firebox of the boiler and heat pipes. For inspection of smokery pipes, there is an observation hatch, which is located in the top of the boiler. The second hatch intended for collector cleaning flue gasesLocated in the back wall of the boiler. In addition, the TT100 boiler has a large part-up space, which allows you to create optimal conditions For heat transfer and distribution of the coolant.

Boilers Entropros. TT100 thermal engineer Comes in various configuration. You can purchase a boiler in a minimum configuration and maximum. TT100 boilers in the maximum configuration are supplied with automation, pumping groups, shut-off reinforcement, set of sensors, burner and other equipment. The price of the TT100 boiler and the size of the discount is consistent additionally, at the preparation and discussion of the commercial offer.

In order to buy the TT100 boiler, you must send an email request or by fax that are listed in the section "Contacts"

Request price

Description

Boilers TT 100 thermal engineer are produced serially in the range of rated power from 1000 kW to 5000 kW. The thermal engineer TT 100 is a three-way steel low-temperature hydrochi-tube-smoke boilers, equipped with a hollow under rise. Boilers are designed for the production of heat hot water With the maximum temperature of 115 ° C with a permissible operating pressure of 0.6 MPa. Boilers are used for work only in closed systems Heat supply. Preferred spheres of application of boilers Thermothechnic TT 100 are large systems of heating and ventilation, hot water supply industrial, administrative, communal and other objects, ensuring the thermal energy of technological equipment of industries. Boilers are certified by the GOST system and are allowed for the use of Rostechnadzor of the Russian Federation.

Features

The TT 100 boiler is designed as a gas-pipe-smoke type boiler. The combustion chamber and the housing of the boiler have a cylindrical shape. The convective surfaces of heating are formed by smokery pipes of the second and third stroke, located symmetrically around the combustion chamber. The two-, three-row scheme for the arrangement of the smoke-step pipes of the second stroke increases the area and the intensity of heat exchange. Fully washed with water The first swivel camera is formed by the rear tube board and a torusferic bottom. The second rotary chamber is formed by an anterior tube board and a specially formed lining of the front door of the boiler. The front cap can be completely folded, or to open with a burner installed on it, if desired, right or left. With an open front lid, convenient access to the combustion chamber and smoke trumpets maintenance And cleaning the boiler. Inspection and cleaning the first rotary chamber can be made through the combustion chamber. For the inspection of smokery pipes from the water space in the upper part of the boiler housing, observation hatch is provided. Cleaning the flue gases is made through the hatch in the vary flue gas chamber of the boiler. Pipes of the entrance and water outlet, as well as the nozzle of the emergency line are located on top of the boiler. Boilers TT-100 with a capacity of 2000 kW and more have two emergency line noise. In the nozzles and water outlet, the fittings for the temperature sensors are welded. Under the water input nozzle, a water-controlled element is mounted for smooth mixing cold reverse water With warm boiler. For mounting the burner on the front cover there is a burner stove. Visual control of the flame in the combustion chamber is carried out through the observation eye. The nozzle of the flue gases is located at the top of the rear wall of the boiler. For a uniform distribution of the weight load, the boiler has a frame base from a chapellor. The solid covering heat insulation of the boiler consists of mineral wool mats with a thickness of 100 mm. Outside, the boiler housing will be covered with a protective casing of aluminum sheet. For the transportation of the boiler, shots welded to the upper part of the case are symmetrically relative to the center of the masses of the boiler.

Specifications

Indicators TT-100 TT-100 TT-100 TT-100 TT-100 TT-100 TT-100 TT-100 TT-100
Thermal power, kW 1000 1500 2000 2500 3000 3500 4200 5000 7500
Water pressure, MPa 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6
Water temperature at the outlet, ° С Up to 115. Up to 115. Up to 115. Up to 115. Up to 115. Up to 115. Up to 115. Up to 115. Up to 115.
Estimated fuel gas / Diesel / Mazut gas / Diesel / Mazut gas / Diesel / Mazut gas / Diesel / Mazut gas / Diesel / Mazut gas / Diesel / Mazut gas / Diesel / Mazut gas / Diesel / Mazut gas / Diesel / Mazut
Efficiency,% From 92. From 92. From 92. From 92. From 92. From 92. From 92. From 92. From 92.
Dimensions (LXBXH), m 2.89x1.54 x 1,77 3.0 x 1,54 x 1,77 3.5 x 1.74 x 2.07 3.75x1.74x2.07 4.1x1.94x2.23 4.56x1.94x2.23 4.96x2.1x2,4 5.13х2,2х2,48. designed
Mass of the boiler, kg 2790 2950 5240 5500 6900 7900 9900 12000 designed

Purpose:

TT100 thermal engineering - smoke-maritime-tube low-temperature three-way hydroelectric water boilers of different power (from 1000 to 15000 kW). Purpose: Production of heat hot water with parameters: Maximum excess operating pressure - 0.6 MPa, the maximum temperature is 115 ° C. Boilers operate on a liquid and gaseous hydrocarbon fuel.

Competently thought-out fastening of heat pipe in combination with a large volume of boiler water and high strength guarantee long term Boiler service thermal engineer TT100. Due to the low heat change of the firebox, the boiler is compliance with environmental requirements. The operational efficiency of boilers The thermal engineer TT100 contributes to the high efficiency and small hydraulic resistance.

The priority spheres of the use of TT100 boilers are large heating and ventilation systems, as well as hot water supply of various utility and production facilities.


Technical description:

Boilers Thermothechik TT100 is used for the production of heat hot water exclusively in closed heat supply systems.

Design

  • Gas boilers The thermal engineer TT 100 is structurally performed as three-way gas-tube boilers.
  • The housing of the boiler and the heat pipe of the cylindrical shape form a combustion chamber. Convective surfaces of heating (smokery pipes of the second and third stroke), asymmetrically arranged around the combustion chamber. Due to the 2x and 3x nuclear laugh, the placement of the smoke-step pipes of the second stroke is ensured by the high intensity of heat exchange.
  • The design of the front cap of the boiler allows it to be completely opened with a mounted burner in any direction. The open front door provides easy access to the smokery pipes and the combustion chamber during the cleaning and maintenance of the boiler. At the bottom of the cover installed auxiliary guides, which facilitates the closure of the door.
  • Looking hatch, located in the upper part of the housing from the coolant, allows you to inspect the smokery pipes.
  • The most optimal mode of functioning of the boiler in the entire heat-producing range is facilitated by a large amount of water in the boiler and a wide interbag space.
  • On the front door there is a burner plate for mounting the burner. Visual flame control in the combustion chamber is implemented through the observation eye.
  • A durable frame base provides a uniform distribution of the weight load of the boiler.
  • Laminated mineral wool mats thick 100mm form highly efficient solid heat insulation of the boiler. Outside the boiler is lined with a corrugated aluminum coating.
  • Transportation and movement of the boiler during installation and loading and unloading work is facilitated by the presence of lifting loops on the housing installed symmetrically relative to the center of mass.
Characteristics:
Size of the boiler 1000 1500 2000 2500 3000 3500
1000 1500 2000 2500 3000 3500
Efficiency at least,%92
115
60
0,6
190
Hydra Resistance, kpa2,9 6,6 5,3 8,3 3,8 5,2
0,29 0,65 0,42 0,65 0,71 1,0
Water volume of boiler, m31,76 1,86 2,8 3,0 4,1 4,6
57 86 115 143 172 200
2980 3260 4680 5100 6960 7480
Flue gas yield, mm300 300 500 500 500 500
Log in / out of water, mm125 125 150 150 200 200
Safety valve, mm50 50 65 65 65 65
G 1/2-B
G 3/4-B
G 1/2-B
Drain of boiler water, mm40 50
Condensate removal, mmG 1-B
TAGONORODER, MM.G 1/2-B
Size of the boiler 4200 5000 6500 8000 10000 12000 15000
Nominal heat production, kW4200 5000 6500 8000 10000 12000 15000
Efficiency at least,%92
Max. Water temperature at exit, hail115
Min. Temperature of water at the entrance, hail60 70
Max. Excessive water pressure, MPa0,6
The temperature of the outgoing gases, no more than hail.190
Hydra Resistance, kpa6,4 3,7 2,4 3,7 7,8 3,3 4,1
Aerodines. Resistance, kpa0,84 1,2 11 12 14,4 14 17
Water volume of boiler, m35,4 6,4 7,7 9,6 12,1 15,5 20
Water consumption Nominal, m3 / h240 287 386 475 594 713 891
Mass of dry boiler no more than kg9400 10440 14000 16000 20000 24000 32000
Flue gas yield, mm650 650 800 800 900 1000 1100
Log in / out of water, mm200 250 250 300 300 350 400
Safety valve, mm80 80 100 100 125 125 125
Water temperature sensor at the entrance, mmG 1/2-B
Water temperature sensor at the outlet, mmG 3/4-B
Flue gases temperature sensor, mmG 1/2-B
Drain of boiler water, mm50
Condensate removal, mmG 1-B
TAGONORODER, MM.G 1/2-B

Documentation:

TT TT 100.- Three-way steel low-temperature hydrochruph-smoke-chimal boilers equipped with a supercharge furnace. Boilers are designed to produce heat hot water with a maximum temperature of 115 ° C with a permissible operating pressure of 0.6 MPa. Boilers are used for work only in closed heat supply systems.

Application:Preferred areas of application of boilers in St. Petersburg are large heating and ventilation systems, hot water supply industrial, administrative, utility and other objects, providing thermal energy of technological equipment of production.

Constructive features:

Gas boilers The thermal engineer TT 100 is designed as a three-way gas-tube boiler.

Camera combustion - heat pipe and boiler housing have a cylindrical shape. The convective surfaces of heating are formed by smokery pipes of the second and third stroke, located axisymmetrically around the combustion chamber. The two-, three-row diagram of the arrangement of the second-running pipes provides a high heat exchange intensity.

The front cap of the boiler can be completely opened with a burner installed in any direction. With an open front door, it provides convenient access to the combustion chamber and smoke trumpets when maintaining and cleaning the boiler. At the bottom of the lid, auxiliary guides are provided that facilitate the process of closing the door.

For the inspection of smokehead pipes from the coolant in the upper part of the boiler housing, observation hatch is provided.

Wide intercoux space and a large amount of water in the boiler provide the most optimal mode Boiler operations in the entire range of heat production.

To mount the burner on the front door there is a burner stove. Visual control of the flame in the combustion chamber is carried out through the observation eye.

For a uniform distribution of the weight load, the boiler has a solid frame base.

The solid highly efficient heat insulation of the boiler consists of laminated mineral wool mats with a thickness of 100 mm. The surface of the boiler is lined with a corrugated aluminum coating, providing spectacular appearance Throughout the service life.

To move the boiler during installation and loading and unloading work on the housing of the boiler, lifting loops are provided, installed symmetrically relative to the center of the masses of the boiler.

Two- and three-row scheme for the arrangement of smokery pipes (as well as the use of heat-resistant intensifiers in last prosecution flue gases in boilers with a capacity of 1 to 2.5 MW) increases the intensity of heat exchange, and, consequently, the coefficient useful action boiler.

Technical characteristics of boilers TT - 100 (1000-5000 kW)

1000 1500 2000 2500 3000 3500 4200 5000

Type of fuel


Propane-butane according to GOST 20448-90
0,6
115
60
57 86 115 143 172 200 240 287
2,9 6,6 5,3 8,3 3,8 5,2 6,4 3,7

Flue gases, kg / s

0,45 0,68 0,90 1,13 1,35 1,58 1,90 2,25
0,29 0,65 0,42 0,65 0,71 1,0 0,84 1,2

The volume of the furnace, m3

0,692 0,793 1,390 1,500 2,260 2,520 3,440 4,270

Water volume of boiler, m3

1,76 1,86 2,80 3,0 4,10 4,60 5,4 6,4
2980 3260 4680 5100 6960 7480 9400 10440

Overall dimensions SHHDHV, mm

1631x
2576x
1768
1631
x2667x1768.
1827x
3134x
2043
1827x
3384x
2043
2022x
3744x
2228
2001x
4144x
2228
2126x
44490x.
2400

2248x
4674x
2370

Technical characteristics of boilers TT - 100 (6500-15000 kW)

Nominal thermal power, kw 6500 8000 10000 12000 15000
Type of fuel Natural gas low pressure According to GOST 5542-87
Propane-butane according to GOST 20448-90
Light fuel according to GOST 305-82
Maximum overpressure of water, MPa 0,6
Maximum water temperature at the outlet of the boiler, 0s 115
Minimum water temperature at the entrance to the boiler, 0s 60
Water consumption Nominal for ΔT \u003d 15K, m3 / h 384 474 591 710 888
Hydraulic resistance of the water tract at the flow rate of the coolant for ΔT \u003d 15k, kPa 6,7 5,6 8,9 5,5 6,1
Flue gases, kg / s 2,88 3,55 4,44 5,32 6,66
Aerodynamic resistance of the gas tract for maximum power, kPa 1,06 1,14 1,44 1,4 1,74
The volume of the furnace, m3 5,240 6,566 8,450 10,870 13,870
Water volume of boiler, m3 7,4 9,6 12,1 15,5 20
Mass of dry boiler, (tolerance of mass 4.5%), kg 13600 16000 19100 22100 28400
Overall dimensions SHHDHV, mm 2360x
5042x
2655
2500x
5373x
2706
2640x
5945x
2859
2823x
6465x
3060
3040x
7015x
3262

Boilers are certified by the GOST system and are allowed to use Rostekhnadzor RF
The warranty period under the observance of the conditions for transportation, storage, installation and operation is 36 months from the date of commissioning, but not more than 42 months from the date of shipment from the manufacturer.

The regulatory life of the boiler is 20 years (subject to the requirements and conditions of installation and operation guide).

The metal water heating boiler TT100 is predominantly used in such spheres as:

  • large heating and ventilation systems
  • roast industrial water supply
  • administrative
  • municipal and other objects
  • supply solar energy Scientific and technical equipment of production

Termotechnik gas boilers TT 100 are created as a three-way gas-tube boiler.

Most users independent Systems The management does not deserved do not trust the technique of domestic production. Domestic technicians consider not able to make the required tasks and avoid when choosing all the devices where the manufacturer is the Russian Federation. Gas boilers The Termothechik does not claim serious competition with Czech, German, Italian and other European models, but in the work they show themselves to pretty high levelAnd the cost of them at times is a budget.

The main advantages of gas boilers

The main advantage of all national products is the budget value, easily infamous spare parts for repair and readiness for work in difficult conditions that can withstand not any gas imported boiler. Among the main advantages of boilers on gas from cast iron are distinguished:

  • Gradual reduction or power increase
  • Pretty simple and understandable management
  • Hot water preparation process
  • Increased security
  • Minimum heat loss
  • A small level of thermal loss
  • Simple service
  • Durability of the aggregate

Principle of operation

Coppers Thermal technology on gas are standard devices that do not have any unique design parameters. On the burner B. working chamber Continuous methane feed is performed, burning and giving thermal energy. Next to the burner is a heat exchanger, where the transfer to the coolant temperature is performed. Then the heat exchanger is constantly circulating through the system, in order not to be cooled by the batteries, while maintaining a suitable microclimate.

Computerized automation is responsible for the control process and removes readings from control sensors, depending on the information received, which manages further actions. The operating parameters cannot be compared with well-known world-class manufacturers, but for the domestic market they are located at a sufficient high level. Gas boiler from cast iron is suitable solution creating all existing heating systems Housing, as its use refers to connecting the already specified cycle. Usually, the gas boiler from the cast iron is connected to the old heating system indoors, due to an increase in reliability and increasing power.