Choose a gas boiler brand Junkers. Models of gas boilers Junkers - from economical to premium Hydraulic scheme of the gas boiler Junkers Evrolaine

Requirements for heating gas devices are high, since devices of this kind are purchased for long operation. The products of the Junkers brand always answered the most stringent requirements in this area and rightly enjoy tremendous success.

Gas Individual boilers Junkers are distinguished by traditional german quality components, rich model near, wide opportunities and inspire the unconditional confidence of hundreds of thousands of buyers around the world.

A bit of history

Junkers (Junkers) was established in 1895 for industrial production of gas devices for individual consumers. Production was located in the city of Düsaau. The company name appeared thanks to the name of the German industrial engineer Hugo Junkers, the famous inventor of the XIX century in the area of \u200b\u200bthermal techniques, having almost two hundred inventive patents.

By 1904, the company mastered the production gas water heaters and other equipment. The use of advanced technologies made it possible to develop a gas supply management system depending on the flow rate hot water.

In 1932, due to the global crisis, the Junkers management sells his concern Bosch, which continued the development of the concern and its production. New plants were opened, improved quality control of products, continued the development of new technologies, for example, embodied the idea of \u200b\u200bpiezorocal flame for columns. After 10 years, heating boilers were launched in production attachment. And in 1985, mass production of gas boilers with an eco-friendly system of pure combustion began. The company produces household gas devicesin which the combustion chamber is closed and there is no need to connect the chimney.

Today, Bosch Thermotechnik is one of major producers devices gas heating in Europe.

The product range of the Junkers brand includes gas outdoor and wall boilers, solid fuel boilers, columns for water heating.

Additional elements and spare parts for aggregates of this brand are inexpensive, and in quality are superior to competitors. The company establishes a 25-year warranty period for its products.

Consider several series of products of this brand.

Junkers Ceraclass.

The line of wall boilers is represented by models with Junkers Ceraclass ZS indexes, ZW of various performance and design features.

They are intended for mounting heating in apartments or houses are not very large square, up to 150 square meters.

ZS boilers have one contour and are intended only for the heating of premises. You can connect an external drive of the boiler type to this boiler.

ZW boiler having 2 contour, except for the heating function, will provide your hot water.
Boilers are equipped with burner both open and closed typeAll models are equipped with an electric auto-shirt, a three-step pump, the presence sensors or absence of traction are protected from overheating. It is possible to connect the thermal sensors indoors, which will ensure automatic support for the desired temperature in all rooms. The automatic electronic control system is equipped with a liquid crystal display showing the temperature of the heating circuit and the current operation mode.

Instructions for Bosch Junkers Ceraclass:

Boilers Junkers Ceraclass Comfort

This series includes models with ZWE index of various modifications. These are boilers with two circuits, requiring chimney mounting. They are equipped with an electric vehicle, a diagnostic program. possible faults. Boilers are equipped with a digital liquid crystal indicator, which shows the value of the current temperature, the boiler mode and the presence of errors. Energy-saving water pumps are built into heating, automated control and control of the flame is implemented. gas burner and thrust, the device is protected from overheating.

Instructions for Bosch junkers units of this line:

Junkers Ceraclass Excellens.

This series is represented by heating units with ZSC, ZWC indexes. Their power allows you to damn the premises of a large area. They can be connected to chains and increase the heating area even more. Individual gas boilers Junkers Ceraclass Excellence are designed to connect to a smart home. They allow separately adjust the temperature in various circuits, for example in warm floors and radiators. They can be controlled remotely via the Internet. Security support 9 special sensors that report all failures, errors and faults.


Heat exchangers of gas boilers Junkers of this series are fully made of copper materialWhat increases heat exchange and device reliability. This part of the boiler contains more special plates than that of competitors, so water heats up more efficiently. Modern system Recycling provides the possibility of instilling hot water in any crane, regardless of the distance to the boiler.

Instructions for Bosch junkers of these models:

Condensation boilers

Includes brands of Junkers CeraPur Smart, CeraPur Comfort, CeraPur ACU, CERASMART MODUL - condensing gas boilers of different walls of wall or outdoor performance.

Boilers of this series are equipped with three-stage pumps, the possibility of controlling the heating of hot water and the intensity of heating, and troubleshooting indicator automatic system Control. The device with ZW23 index contains a heat exchanger from of stainless steelWhat allows you to provide high performance when water heating. Competently designed body design makes it possible to harmoniously place the boiler in the kitchen. The device is equipped with an electronic controlled burner ignition and malfunction diagnostic system. maybe additional connection Temperature sensor in the room. The ZW index boilers perform the functions of heating and hot water supply, and ZS is only heating.

Junkers eurostar

Boilers of this wall-mounted model, with a two-stage pump, regulators of the heating intensity and water heating temperature. Be sure to present an autoelectronic control program and digital malfunction diagnostics. Comfort mode minimizes water heating time. The boiler can operate in two hot water supply modes - in economical or comfortable. Devices with ZWE index and DHW, ZSE - heating.

Euromaxx.

These gas boilers are equipped with a circulation type pump, they have cranes to feed the heating circuit, the water consumption limiter is built. It is possible to select the desired temperature of water heating and heating intensity. Automation controls the flame, pressure in the heating circuit. EUROMAXX series boilers are protected from freezing, have a reverse thrust control. Manifunted multifunctional bosch system Heatronic.

Will the repair take?

The main fault of the Bosch junkers boilers is the failure of the control module. Boards in these devices are very capricious. It is quite difficult to repair them and often it has to acquire a new one that is extremely expensive.

To protect yourself from such problems, it is necessary to install a boiler voltage stabilizer, an insulating gas and grounding clutch.

In addition, problems are possible with the launch when the flame is on after the electrical location, it burns 3-5 seconds, then goes out and so several times. If the flame lights up, then it is not strong as usual. The hull of the boiler is heated, and the water temperature does not rise above 45 C. This malfunction can be eliminated by high-quality cleaning the combustion chamber and burner. After that, the fault is usually disappeared and the boiler works fine.

Record posted on 11/05/2014 by the author.

Instructions for installation, operation and maintenance of gas boilers EUROLINE ZS 23-1 AE 23, ZS 23-1 AE 31, ZW 23-1 AE 23, ZW 23-1 AE 31. Language: RU | PDF 1006.80 KB.

Installation instructions, setup, re-equipment of the discharge system flue gases For installations of gas heating ZW / ZS 23 AE. Language: RU | PDF 359.33 Kb.

Instructions for installation, operation and maintenance of gas boilers EUROLINE ZS 23-1 KE 23, ZS 23-1 Ke 31, ZW 23-1 Ke 23, ZW 23-1 Ke 31. Language: RU | PDF 761.04 KB.

Instructions for installation, operation and maintenance of gas boilers Euromaxx zws 24-1 MFK 23, ZWS 24-1 MFK 31, ZWS 28-1 MFK 23, ZWS 28-1 MFK 31, ZWS 24-1 MFA 23, ZWS 24-1 MFA 31, ZWS 28-1 MFA 23, ZWS 28-1 MFA 31. Language: RU | PDF 4.60 MB.

Installation, operation and maintenance instructions for wall gas ZWE 24 / 28-4 MFA ..., ZSE 24 / 28-4 MFA independent of indoor air. Language: RU | PDF 1.28 MB.

Installation, operation and maintenance instructions for wall gas boiler EUROSTAR ZWE 24-4 MFK 21/23, ZSE 24-4 MFK 21/23, for connecting to chimney. Language: RU | PDF 314.47 Kb.

Instructions for safety, commissioning, recommendations for saving energy boilers of wall gas EUROSTAR ZWE 24-4 MFK 21/23, ZSE 24-4 MFK 21/23, ZWE 24 / 28-4 MFA, ZSE 24 / 28-4 MFA . Language: RU | PDF 314.47 Kb.

Installation, operation and maintenance instructions for wall-mounted gas boilers EUROSTAR ZE / ZWE 24-3 MFA, ZE / ZWE 24-3 MFA. Language: RU | PDF 1.22 MB.

Installation, operation and maintenance instructions for wall-mounted gas boilers EUROSTAR ZSE / ZWE 24-3 MFK. Language: RU | PDF 940.48 Kb.

Instructions for installation, operation and maintenance of wall-mounted gas boilers EUROSTAR ZE / ZWE 24-3 MFK ... Language: RU | PDF 460.77 KB.

Gas wall boilers Junkers series Ceraclass: ZS 14 - 2 DH AE 23, ZS 14 - 2 DH AE 31, ZW 14 - 2 DH AE 23, ZW 14 - 2 DH AE 31. Installation and operation instructions. Language: RU | PDF 3.75 MB.

Gas wall boilers Junkers series Ceraclass Excellence: ZSC 24 - 3 MFK, ZSC 28 - 3 MFK, ZWC 24 - 3 MFK, ZWC 28 - 3 MFK. Installation and maintenance instructions. Language: RU | PDF 4.84 MB.

Gas Wall Mounted Boilers Junkers Ceraclass Excellence Series: ZSC 24 - 3 MFA, ZSC 28 - 3 MFA, ZSC 35 - 3 MFA, ZWC 24 - 3 MFA, ZWC 28 - 3 MFA, ZWC 35 - 3 MFA with Air Fence for Combustion Outdoor . Passport. Installation and operation instructions. Language: RU | PDF 5.44 MB.

Gas Wall Mounted Boilers Junkers Ceraclass Comfort Series: ZWE 24 - 5 MFK. Passport. Installation and operation instructions. Language: RU | PDF 1.96 MB.

Gas wallpapers Junkers series Ceraclass Comfort: ZWE 24 - 5 MFA, ZWE 28 - 5 MFA with air fence for combustion outdoors. Passport. Installation and operation instructions. Language: RU | PDF 2.05 MB.

Gas wall boilers Junkers Ceraclass Smart series: ZWA 24 - 2 K 23, ZSA 24 - 2 K 23. Installation and maintenance instructions. Language: RU | PDF 3.78 MB.

Gas wall mounted boilers Junkers Ceraclass Smart series: ZWA 24 - 2 A 23, ZSA 24 - 2 A 23. Installation and maintenance instructions. Language: RU | PDF 3.61 MB.

Gas wallpapers Junkers series Ceraclass: ZS 14 - 2 DH KE 23, ZS 14 - 2 DH KE 31, ZW 14 - 2 DH KE 23, ZW 14 - 2 DH KE 31. Installation and operation instructions. Language: RU | PDF 3.75 MB.

Boiler "Junkers" is subject to faults as well as another technique. The manufacturer simplified the search for the cause of the problem, developing a self-diagnosis system. Any malfunction is displayed on the display of the error code. You can only find out the code value, after which you will repair the technique, or call the master of the master.

Device and operation of gas boilers Junkers

The boilers of the brand "Junkers" are presented in two versions: classic and condensation.

The series of classical aggregates includes CeraClass Comfort, Ceraclass Exelless, Junolain Junkers (EUROLINE). This is single-mounted I. double-circuit modelsMounted on the wall. Open and closed cameras can be connected to the main chimney or remove the gases through the hole in the wall.

The design is equipped with a copper heat exchanger and circulating pump that injected fluid into the heating system. There is also a plate radiator for water heating.

CERAPUR SMART, COMFORT, ACU is condensation boilers. This system provides economical fuel consumption due to the use of steam. Wall and floor vehicles are equipped with condensate collections. The principle of operation of the system is shown in the picture:

The output of combustion products occurs through coaxial chimney. Some models have remote control.

Fault codes

Deciphering values \u200b\u200byou can find in the instructions and our table.

Error code (flash LED indicator) Value Ways of elimination
"Junkers Evrolaine"
45 (alternate glow diode 90). Bad thrust. For closed models:
  • Verification of fan performance.
  • Diagnostics of the pressure switch.

For atmospheric cameras:

  • Checking for thrust. Cleaning the chimney mine.
  • Inspection of the thrust sensor, replacement when breakdown.
60 Malfunction of the electronic module. Perhaps burned ignition resistor or other element. The diagnostics of the electronic part is required.
75 Damage to the main module. Damage to the circuit of the ignition, ionization. Humidity on the board is removed by drying the item.
90 Problems with temperature limiter. Check and replacement:
  • Hot water sensor.
  • Thermostat.
  • Control boards.
  • Inspection of the duct for a blockage.
Junkers Eurostar, Junkers Ceraclass
AA The feed temperature in the heating system exceeds the norm. Low water current. What to do:
  • Clean the heat exchanger plates from dust brushed. Internal parts are cleaned from scale with a special solution.
  • Diagnostics of the humus service.
  • When a thermal sensor malfunction, install a new item.
A4. Bad burning products. Hacking gases from the camera interferes with something, clean the system.
A7. Damage to the hot water temperature sensor. Check the details, its contacts and put a new item if necessary.
A8. The connection of the regulator is broken. Replacing the regulator.
A9. The temperature sensor is incorrectly installed. Set the sensor correctly.
AD No connection with a thermal sensor boiler. Inspection of contacts, connections, wiring. Diagnosis of sensors.
C4. Broken pressure switch. The inspection of the switch, wiring, the integrity of the tubes is performed.
C6. Felt breakdown. The fan in the closed cameras is responsible for the removal and injection of air. It is necessary to find out the cause of the breakdown and carry out repairs.
SS No connection is defined with an external thermometer. Tighten the contacts, make sure the integrity of the wiring and state of thermometer is integrity.
Ce In the system, the heating decreased pressure. Measure the indicators and the result of water if necessary.
CF. Cleared pressure sensor. Similar activities CE.
E2. The sensor that determines the water temperature during submission is damaged. Make sure the wires are not damaged and the contacts are closed.
Error E9. Worked the heat exchanger thermostat or flue gases. Inspection is performed:
  • thermostat;
  • control board;
  • pump.

Cleaning the chimney shaft.

EA The flame in the burner is not determined.
  • Open the gas valve.
  • Find out whether the fuel flow relays works.
  • Eliminate radiator zoom, condensation siphon.
  • Check for thrust in the chimney.
F1.
F7. The device is disabled, but the flame is determined. Restarting the system.
FA. The gas is disabled, but the system shows the presence of a flame. Actions are similar to F7.
FD. Randomly press the "Reset" key. Press again.
"Junkers" with board S4962
E01 / E02. The boiler does not recognize the flame; An indication of its presence when the fuel is blocked.
E03 Overheat. Contacts with overheating sensor broke. Diagnosis of elements.
E04 The press space chain closed to ignition.
E05 The press service does not work. The fan does not rotate. Check chain, fan and press space.
E06 The chain of the air sensor does not closes, for 5 attempts to ignite. Act according to E05.
E07 The fan protection turned on.
E08. Incorrect operation of the ionization scheme. Diagnosis and repair.
E09 Incorrect operation of the GC scheme.
E10. Error EEPROM memory. Installing a new module.
E30 (wiring violation); E31; E32 Thermostat NTC CH Heating. Check and repair chains.
Sensor GVS NTC DHW.
NTC FLUE flue gas sensor.
E33 Overheating in the heating. Cleaning the heat exchanger from scale, adjusting the temperature on the panel.
E34 / E35 Insufficient voltage in the network. Wait until the feed is restored.
E37 Overheating of combustion products. Spend the sensor, passability of the removal paths.

To avoid premature breakdowns, experts recommend:

  • Carry out the maintenance of the boiler at least once a year;
  • Install cleaning filters for water;
  • Clean knots from dust, soot, scale;
  • Control the permeability of the combustion products removal;
  • Do not install the heating temperature above 60 degrees.

Be careful to your technique. Do not tighten with the repair: if you noticed the signs of problems, try to eliminate it. Or contact the service center.


German company Junkers One of the first to develop and implemented a gas pressure control system depending on the flow of water, as well as the function of eco-friendly gas burning.

The assortment of Junkers presents installations with a closed and open furnace chamber, in an outdoor and wall-mounted version, with one and two contours. All gas boilers brand Junkers are granted a 25-year warranty.

Condensation equipment

Junkers has a mounted condensation boiler closed Camera combustion. Depending on the configuration, it can be installed for the heating of rooms up to 500 square meters. m. manufactured in three basic equipment:


Condensation models have a small gas consumption, which reduces the cost of heating by 30-40%.

Wall-mounted equipment (atmospheric)

Hinged single-circuit and dual-circuit gas boilers of heating Junkers, with an open combustion chamber (atmospheric) are presented with a series of Ceraclass, in which two main modifications are: Comfort and Excellens.
  • Comfort - The boiler device allows you to reduce the number of possible faults and increase the service life. A self-diagnosis program has been installed, information about problems in work and faults is issued on the LCD display.
    In the basic configuration, Comfort is all the necessary equipment: circulation pump, Gas burner control, sensors and devices that protect against overheating.
  • Excellens - The modification includes as wall-mounted single-mounted gas heating boilers Junkers brands and dual-circuit counterparts. Have high performance. Can connect to the system smart House. The possibility of connecting several heating systems At the same time.

Outdoor boilers

Outdoor gas boilers Junkers are designed for household and industrial applications. The maximum performance reaches 56 kW, which is sufficient to maintain a comfortable room in the room to 500-600 m².

The connection of two floor gas heating cats Junkers to one network (cascade) is allowed. If necessary, you can install an indirect heating boiler.

The advantage of models of floor boilers of heating Junkers is that their heat exchanger is made of refractory cast iron. This made it possible to increase the coefficient of heat transfer, as well as the operating deadlines.

In floor units, according to the manufacturer's assurance, antifreeze can be used for boilers. This increases the heat transfer in heating several times, and also prevents the heating system from defrosting.

Output and commissioning

Connecting the boiler does not require the installation of additional circulation equipment. The design includes a pump, expansion tank, Sensitive automation and control unit. All models can additionally be equipped with room temperature sensors.

Installation of water treatment is required. Interior design The heat exchanger is sensitive to the effects of the aggressive medium, so before entering the supply of the heating system to the boiler, the coarse and fine filters are installed.

Maintenance of the boiler is simply carried out, thanks to the front removable panel, which opens access to important nodes. Cleaning the heat exchanger is carried out at the beginning and end heating season. Fault diagnostics are carried out in automatic mode, the results are displayed on the display.

Advantages and disadvantages of choosing boiler Junkers

According to consumer reviews, several factors affect the quality of work of the boiler: technical conditions operation, correctly exhibited settings and disadvantages in the design. The most difficult and expensive breakdown is the failure of the control module. Replacing the board will cost a third of the cost of the boiler.

Another common problem occurs as a consequence of poor boiler service. The principle of equipment operation is based on the use of sensors that prevent overheating of the coolant. So, the automation works in the presence of large number Says in the furnace. The water heating temperature in this case does not rise above 45 ° C.

The rest of the boilers, Junkers work, as it should german equipment - with accuracy, performance and reliability. Junkers is good decision For those who primarily appreciate quality and pay for it.