If earlier in the heating equipment above all the reliability was valid, then the ability to work in automatic mode is waiting for it today.

English Holding Baxi Group, a well-known producer of gas boilers, takes into account these requirements: the aggregates produced by them due to high quality we use with good demand.

Our article will assist our advantages, the theme of which is the bucky gas boiler: instructions for use.

According to its device, TM buckci aggregates are not much different from other gas boilers. They consist of several components.

Gas Melting Device

The composition of this node includes several elements:

  1. Gas-burner: In the most accessible models, a burner is installed with a constant power, in more expensive - with stepped adjustment. To maintain a constant temperature in the room, the automation system accounts for such burners to periodically extinguish, and then upload again. In the most expensive boaches, modulation burners are installed, the power of which is adjustable smoothly. Such burners work constantly and in the very optimal mode, Therefore, the set temperature is supported with high accuracy.
  2. Combined gas valve: Allows or blocks the gas supply to the burner depending on the automation devices signals.
  3. Ignition unit: Consists of an electronic circuit and electrode. The network voltage incoming on it This block converts high frequency to high-voltage pulses, which are supplied to the electrode. As a result, a spark flashes between the electrode and burner (in some models - between the two electrodes), gas-air mixture on the burner.

Camera combustion at boilers TM bucki is closed, that is, the air is closed to it from the street. An exception is the model LUNA-3 Comfort 240i, which has an open camera.

The pipe for connecting the gas supply line is located in the middle between nozzles to connect the heating system.

Heat Exchanger

In their aggregates, the company establishes both steel and copper heat exchangers.

The second due to high thermal conductivity are more efficient.

The successful design of the heat exchanger allows you to absorb 90.8% of the heat combustion generated in the cell (some efficiency models are slightly less than - 88.7%).

In addition to the main heat exchanger in the buxi heater, another one, intended for the preparation of hot water, can be located. Such boilers are called double-circuit. Some models, for example, buxi EcoFof 24, can warm the water in an external boiler.

At the entrance to the heat exchanger, a grid filter is installed.

Expansion tank

In different models, the volume of this element can be 8 or 10 liters.

Russian manufacturers heating equipment Much advanced as their equipment. Among popular firms - Condord. Users and review of characteristics, read carefully.

The home heating scheme with a gas boiler is presented.

Video on the topic

Wall mounted gas boilers Baxi. Literally flooded the Russian market of heating equipment over the past decade. This is not surprising. When a potential buyer is a choice: to buy an inexpensive boiler, but the unfinished and domestic, or reliable, but dear production of Germany, then often the choice is made in favor of Italian gas boilers.

As a rule, they are distinguished by a fairly successful ratio of "price-quality" and a developed network maintenanceEasy to find spare parts. Consider the most popular Baxi gas boilers in Russia, which we often have to read on specialized forums, Internet blogs or on the company's official website.

In detail we will analyze the main models, types, device, technical characteristics of wall-mounted (attached) single-circuit and double gas boys, I will identify their main advantages and disadvantages, and we will also understand what they differ in each other according to the instruction manual.

The main models of wall gas boilers of the company BAXI

The following models of wall gas boilers from BAXI are presented in our market:

Baxi Main. Four and (fourth and fifth generation of boilers);
- Baxi Four TECH and BAXI ECO 4S;
- and its more compact analogue of Baxi Eco Compact;
- Baxi Luna-3 and Luna-3 Comfort with a remote control panel;
- Baxi Nuvola-3 with a built-in cumulative boiler.

Wall mounted gas boilers Bakci differ in the type of combustion products and come:

1. Turbated gas boilers BAXI with closed chamber Combustion

A special fan (turbine) is installed in the boiler with which combustion products from the boiler in the atmosphere are deleted forcibly. To do this, you will need to additionally buy, or pipe system for separate smoke removal And air inflows.

The coaxial type of chimney by the type "Pipe in a pipe" is installed by one end (through the knee) on the boiler, and the other end through the wall goes to the street. It is very convenient, because There is no need to specifically burn chimney through the roof.

Gas boiler BAXI MAIN FOUR 240 FI


Such models in Baxi are indicated by the article "F" or "Fi". For example, hinged double-circuit gas boilers BAXI MAIN FOUR 18 F, BAXI ECO 4S 24F or BAXI ECO FOUR 24 F. Figures indicate us to boiler power, i.e. 18 or 24 kW.

2. Baxi atmospheric boilers with an open combustion chamber

If your private house already has a chimney with a diameter of at least 130 mm, then you can buy a boiler with an open camera, the emission of combustion products of which is due to natural traction. Such boilers are often called "atmospheric."

On the Baxi boilers themselves, the diameter of the chimney is 121-122 mm, so the aluminum corrugation is suitable for them with a diameter of 125 mm, capable of to withstand temperatures up to 400 degrees Celsius, which can be stretched up to three meters. Or you can use chimney pipes from of stainless steel same diameter. True, this variant of the chimney will cost somewhat more expensive.

In these models there is no turbine, and in the marking of the boacy boiler there is a article "I", or it is not affordable at all. For example, "BAXI ECO FOUR 24I" or "BAXI FOUR TECH 24".

Baxi wall gas boilers are available in two versions:

1. Single-mounted.

This type of boilers provides only heating of the coolant in the heating system. In these boilers there is only one main heat exchanger. This type of boilers is not very popular, because its value is slightly lower than on double-circuit models.

In turn, a wall-mounted double gas boiler can always be applied only for heating, and the second outline for the DHS does not connect at all.

You can simply buy a double bucksy gas boiler, even in the absence of running water to the perspective. After all, it is possible after some time you will come in handy and the second circuit of this boiler, and you do not have to buy a new device.

2. Double-circuit.

Such boilers enjoy the greatest popularity of buyers, as they say and numerous reviews for Gas boilers BAXI. They are able to work and, like a heating unit, and as a flow gas column. Moreover, during the use of flowing hot shopping water, heating the heating contour does not turn on automatically, unlike many brands of floor gas boilers.

Dual-circuit wall gas boilers have two separate heat exchanger, or one bit farm to heat both contours in one monolithic block. Boilers this type have the greatest demand from potential buyers. Having bought such a boiler, we get in the "one bottle" and a boiler for heating, and for hot water supply.

Features of the device of two-circuit gas boilers BAXI: Instruction

BAXI ECO 4S 24F double-circuit boiler


1. All models are equipped with two separate heat exchangers (except for the Main Four and Main series boilers) for water heating in the heating system and the economic, flowing for hot water supply. The main heat exchanger is made of high-quality copper, secondary for DHW - from a stainless steel.

2. All boilers are equipped with a circulation pump of German manufacturers, or Grundfos, or Wilo. This pump is able to raise the water post in heating system up to 6 meters, which is quite enough for two-storey house or cottage. Built-in pumps for circulation pumps are quite economical and equipped.

3. For maintaining required pressure In the heating system, Boqui boilers have built-in membrane expansion tank 6-10 liters volume. No further buy another one if the total water volume in the system does not exceed 100-150 liters. This individual volume can be founded independently by calculating the total number of radiators sections, the length of the pipe or when filling out the system.

4. Baxi boilers are equipped with a Honeywell gas valve, gas-burner It has flame dividers from stainless steel. All models automatically maintain the temperature of the water in the heating system and in the DHW circuit due to the smooth electronic modulation of the burner.

The boiler security group includes:

- automatic air vent;
- Safety valve with pressure gauge.

Consider the device two-kinning gas boiler Using the example of the model "BAXI ECO FOUR 24F" according to the scheme:

Baxi two-door gas boiler device


1 - hydraulic press service

2 - three-way valve

3 - Motor of the three-way valve

4,22 — safety valves on 3 bars

5 - Honeywell Gas Valve

6 - gas supply tube in the burner

7 - water temperature sensor in the system

8 - flame spark plug

9 - overheating protection sensor (thermostat)

10 - the main heat exchanger

11 - smoke cap

12 - Turbine for emissions of combustion products

13 - Venturi Tube

14,15 - Points. and detention. Pressure

16 - Traction Control Sensor

17 - Gas burner

18 - expansion membrane tank

19 - Circulating Pump

20,21 - drain valve and pressure gauge
23 - Crane for feeding the heating system
24,25 - Temperature Sensors Contour DHW

In addition, an electronic board is built in wall boilers, so-called Brains of the boiler, various sensors: duct, circuit temperature DHW and heating, as well as traction and flame sensors. There is a system for protecting the boiler from freezing and blocking the circulation pump. What does not cancel the mandatory purchase for the boiler of this brand.

Bakci gas boilers: differences in models and specifications

As you can see the lineup The boilers have this Italian manufacturer wide enough. Let us now look more detailed every major models, and find out - what they differ from each other and what features have.

Features of models of boilers of the Baxi Main Four series and Baxi Main 5

The predecessor of the boilers of this series was the devices called Baxi Main, which did not have an LCD display and a number of other functions. In general, the word "Main" in English means "main" or "main". Also in our case, the "Main" series boilers are a basic version of the wall gas boiler from Baxi.

The main distinctive feature is the presence of a bitter heat exchanger. This means that the contour of the heating system, and the DHW circuit is heated in one heat exchanger. Water in circuits is not mixed in the circuits, and flowing water is heated precisely due to the contour of heating.

The fifth generation boiler attracts its compact sizes, but is released only with a closed combustion chamber, unlike the fourth-generation boiler. Can be applied to the heating of a private house or an apartment with an area of \u200b\u200bup to 200-240 m2, have a model range of 14, 18 and 24 kW.

TECHNICAL SPECIFICATIONS BAXI MAIN 5


Features of the boilers of boilers BAXI ECO FOUR and BAXI ECO COMPACT

The main feature of these models is the presence of an additional lamellar secondary stainless steel heat exchanger for heating the DHW contour.

The main (primary) - heats the water only in the heating circuit, and the secondary operates regardless of it, using the coolant from the heating circuit to heat the flow water. Thus, the load on the main heat exchanger is noticeably reduced. Thereby, the service life of both it is increasing, and the gas boiler itself.

Model Baxi Eco Compact. Already in his name indicates us for their small dimensions, due to the best line of internal elements, compared to the same boilers of the fourth series. In addition, they are equipped with a new electronic board. The "ancestors" of the Eco Four series boilers are wall-mounted gas boilers of the third series BAXI ECO 3 Compact.

TECHNICAL SPECIFICATIONS BAXI ECO FOUR


Features of gas boiler models BAXI FOUR TECH

The boilers series are the redundant version of the boilers of the Eco Four series. They are also equipped with two separate heat exchangers made of copper and stainless steel. Them a distinctive feature It is that the hydraulic part (water supply tubes) is not made out of copper, as in Eco Four, and from plastic.

Due to this, the manufacturer managed to reduce the price of wall double-circuit gas boilers with two heat exchangers, and part of the buyers it appreciated: because the boilers of this series also found their firm place in the market. This was especially noticeable due to the ruble collapse in relation to the dollar and euro rate.

Specifications Baxi Four Tech


Additional features and boiler operation

All models are equipped with a digital control panel on which you can set the boiler mode, the temperature of the water in the heating system and the DHW, adjust the warm floors in the temperature range of 35-45 degrees. There is also the ability to adjust the work of the boiler depending on the weather outside the window, thanks to weather-dependent automation, connecting a special outdoor temperature sensor.

Or buy baxi and set the air temperature indoors.
But, unfortunately, these accessories are not included in the package and are purchased separately.
The exception is only the LUNA-3 Comfort model with a remote control panel.

In addition, the display shows errors when operating the BAXI boiler under certain codes, for example, "E 06" - the temperature sensor of the DHW is defective, etc.

Benefits of wall-mounted gas boilers BAXI

- Wide lineup;
- Many service centers in Russia and CIS countries;
- the presence of spare parts from official representatives (dealers);
- acceptable cost.

Disadvantages of boilers Baxi.

- weak electronics (in particular, e-board);
- high sensitivity to poor quality running water;
- Not "native" spare parts.

RESULTS
Today we disassembled wall in detail gas boilers Baxi., considered the advantages, disadvantages of models, their technical characteristics, according to the instruction manual. Also compared what the basic models of this brand of boilers are distinguished and they have made their own review.

Recommend or discourage from buying I will not, choose by you. Read Baxi Gas Boilers Reviews and analyze. I will only say that the ratio of price-quality for boys boilers is quite good, even despite the most severe competition in the heating equipment market. Watch your video review.

Among the many suggestions of climate machinery for the house, a new name has appeared relatively recently. If the instruction manual is the buxi gas boiler famous manufacturer From Italy, it seems that the equipment does not differ from competitors. However, products are presented in the product line, characterized by both the algorithms of the work and the possibility of implementing complex solutions for home heating.

Features of these systems

All buxi gas boilers have a number of features that greatly improve the user characteristics of the device. The advantages of the equipment can be described as a short list.

  1. The flame is always adjustable. The boiler does not just carry out a tag - the launch is made in two stages. At first, the burner warms the combustion chamber, operating at minimum power for about 60 seconds, then proceeds to the level specified by the electronic adjustment unit.
  2. If temperature control sensors are used, the automation supports only the required flame level. This provides more smooth operation, reduces the number of switching cycles of modes. As a result, the boiler serves longer thanks to the smaller wear of the nozzles, the walls of the combustion chamber, superchargers, coils.
  3. Postcirculation system, controlled by signals external sensorsIt is capable of significantly reduced fuel consumption and electricity. The boiler will continue circulating the coolant after turning off the burner, until the signal of the temperature balance is arrived.
  4. Boqui boilers maintain double temperature control. It is possible to manage the operation of automation not only with the help of sensors installed indoors, but also located on the street. This makes it possible to maintain the optimal balance of humidity and the best climatic conditions in the rooms.
  5. The equipment is compact compared to competitors, weighs little. Connecting buxi gas boilers as convenient as possible, carried out by standard schemes both for wall and outdoor models. This makes it possible to minimize the malfunction of buxic gas boilers arising from the wrong operating conditions. You can use equipment with any options for organizing strapping.


Another advantage that is somewhat implicitable for the buyer is the orientation of the Baksy aggregates for integrated use. For example, the instruction on the use of the bucksy gas boiler clear makes it clear that in the event of a strapping using boilers from the same company, the best results will be obtained.

Also, the ruler "Gas boiler with boacy boiler" provides a direct connection of electronic control circuits to create a flexible control system. If we talk about the shortcomings of the boilers of this brand, the following items can be noted.

  1. High price. Compared to the nearest competitors in the market, the equipment has 2-2.5 times a higher price. This is easily explained by the technological work, as well as the best indicators of combustion chambers, climate maintenance stability in the room.
  2. Outdoor boilers are very sensitive to installation. Incorrect installation or location can cause various deviations, among which - increased noiseIgnition with cotton and others. On the main parameters of the work, it almost does not affect, but is concerned.

The high price in the eyes of potential buyers is a key factor that Bakcy's name has not yet been widely known in the post-Soviet markets.

Constructions and execution


In the proposed rules, you can find almost any models. The bucky gas boiler device implies the use of all three main engineering solutions:

  • with an open combustion chamber;
  • with a coercive superior and closed combustion chamber;
  • with a condensation system.

Among equipment suitable for heating an apartment or small house, There is a huge number of wall gas boilers. Presented both single-circuit and double-circuit models. As part of boilers, which provide for outdoor accommodation, a lot of models implying joint strapping with a boiler. You can implement any of the basic schemes:

  • connecting a double-circuit boiler to work with a boiler in the role of buffer of the heating system;
  • using a boiler to ensure the work of a hot water system through a three-way AVK air boiler valve;
  • connecting a heater through an additional control system to implement the capabilities of the maximum speed of selection of hot water from the system;
  • the use of a boiler as a heat accumulator, both for the heating system and hot water supply.

Some characteristics of equipment suitable for heating apartments.

Most interesting for residents apartment houses, as well as hosts of small cottages and private houses wall boilers Series Main, Eco Compact, Fourtech. These boilers have compact sizes, have no special installation requirements, allow connecting to any embossed options, and their performance is sufficient to meet the needs of most users.

To illustrate it, you need to compare devices running on different principles. For a small room for evaluating sizes and thermal power indicators, the FourTech series boilers are perfect.

Model BAXI FOURTECH 24. BAXI FOURTECH 24 F
Type of combustion chamber Open, atmospheric Closed, supercharger
Useful return of heat, kW 24 24
Minimum performance, kW 9,3 9,3
Efficiency at maximum performance 91,20 92,93
Efficiency at the power level of 30% 89,3 90,37
Gas consumption, cubic meters / h 2,78 2,73
Dimensions overall in mm 730x400x299. 730x400x299.
Mass, kg. 29 33

As can be seen technical characteristicsWith very compact sizes of the device and low weight, a good impact of thermal energy is ensured. For comparison, the nearest competitors from Vaillant, equal in power, have large dimensions and weight higher by a third. Also immediately noticeably the dignity of the unit with a closed combustion chamber. He is below gas consumption on all power indicators, as well as the best coefficient useful action. When working with a boiler, financial investments will pay much faster.

Malfunctions and methods for their solution

If we talk about problems, it is worth noting that the electronic control systems maximize security. The technical solutions embedded in a special algorithm of work allow you to raise the level of reliability even higher.


However, some failures still happen. Separate malfunctions and methods for their solution are provided in the instructions for the use of buxi gas boiler. Typical problems can be defined by the fault code on the indicator.



Buckuck gas boilers - reliable equipment, the level of user characteristics of which is quite responsible for a high price. Thoughtful modes of operation guarantee long service, And the use of strapping with boilers and joint management can ensure excellent economic efficiency of the heating system as a whole. Boqui boilers, thanks to the possibility of equipping by sensors and thermostats, can work without human intervention, providing excellent temperature regime.

Tariff growth and the inaccessibility of centralized resource highways in remote areas contribute to the development of autonomous systems for providing private houses with heat and hot water.

Most successful options Boilers are recognized to heat hot water, nutrition and circulation of the coolant in heating circuits or warm floor systems.

There are many firms engaged in the production of heat engineering equipment, which develop and improve the design of heating units.

Most effective and economical are considered gas plantswhich are noticeably dominated over other types of heating boilers.

The most important operational procedure is the setting that will be considered on the example of the Gas boilers of the Italian company BAXI.

Mounting the boiler consists of several stages:

  1. Installation of the water filter on the pipeline, bringing water to gVS system. It is necessary to deliver cutting valves on both sides, ensuring the possibility of dismantling the filter for maintenance, repair or replacement.
  2. Placing an aggregate in a reserved place. Outdoor devices are simply placed at the desired point of the room, the wall boilers are hung on the surface of durable walls. Does fastening on plasterboard partitions or other structures that do not have sufficient carrier ability. Fastening to the wall is made on special brackets (sleds), which are included in the package.
  3. All undermining pipelines are joined - gas, heat carrier direct and reverse line, DHW. The coaxial chimney is installed and attached (some models are equipped with double chimney vertical type). Immediately checks the availability and quality of thrust.

The final step is to connect the boiler to the power supply network. For this, a separate outlet is needed, the power of other devices from it is prohibited by the rules of operation.

User's manual

It is primarily necessary to wash or clean the heating circuit and chimney. Any contamination is capable of violating the nominal mode of operation, which will cause accelerated wear of certain nodes and failure the entire system.

Connecting the boiler must be performed by specialists from an authorized service center, they also perform the primary setting of the installation.

Boilers pass pre-sale preparation And come to the trading network completely ready for launch. This means that no additional actions are required.

This is the application of the manufacturer, but in practice almost always has to adjust the settings in accordance with the existing technological or technical Conditions. Basically, the setting consists in determining the minimum and maximum gas pressure and the temperature range, which determines the inclusion and disabling the boiler.

NOTE!

All settings must be performed by employees of service organizations. The warranty period begins from the moment of launch, and independent inclusion may be regarded as a violation of the contract with service centerAs a result, the repair will be denied.

How to turn it on

Connecting the boiler to the power supply network is made only after the addition of all pipelines supplying water, OV and gas.

It is necessary to carefully check the correctness of the connections, special attention Pay gas pipeline.

Check with soap solution Lack of leaks, when deficiencies are found, immediately fix them on their own or with the involvement of specialists of the corresponding profile. After that, the boiler can be filled with water, opening the fuel tap.

Pressure should be from 0.7 to 1 mbar. When the pressure reaches the desired value, you can start the boiler.

First start

After connecting all communications and power supply, you can turn on the boiler.

Procedure:

  • Open gas crane.
  • Install heating and gWS feed (or only DHW). These modes correspond to the designation "Winter" and "Summer".
  • Install the desired temperature by pressing the "+" or "-" buttons.

After that, there will be a launch of the burner and the boiler will start working. Often, after the first launch, the error and the boiler immediately pops up on the display.

This is due to the air remaining in the pipelines. By pressing the "R" button and hold it for a few seconds, the error and restart of the unit are reset. Until complete air removal, several repetitions of such a situation may occur.

Air can be released faster if you open access to the pump and weaken the screw. The procedure is performed when the power is turned off. The air will be released from under the pump cover, as soon as the water goes, the screw immediately delays and the equipment starts again.

How often should it turn on?

The inclusion frequency of the boiler depends on several factors:

  • The power of the unit.
  • The correctness of the boiler settings.
  • The presence of a room thermostat.

With excessive power, the installation quickly heats up and turns off. Circulation pump Provides the receipt of new portions of the cooled coolant, the temperature sensor triggers and starts the boiler again.

Power can be reduced by programmate. It is also necessary to reconfigure the boiler, in particular - to increase the parameter F11 (waiting time before repeated) to a maximum that is 10 minutes.

The use of the thermostat can significantly increase the time between the launch of the unit, since the air cools and heats up much slower.

Temperature adjustment

To add or drop the temperature on the right and left of the display, there are "+" and "-" buttons (on older models there is a special regulator, turning clockwise The temperature rises and vice versa).

If a room thermostat is used, the adjustment is made from it, and only limit values \u200b\u200bare installed on the boiler.

When tuning the temperature, you should not change the parameters of jumps to large values. It is necessary to change the mode smoothly, give some time to overcome the inertia of the system. This will mitigate the transition to another mode and extend the service life of the boiler.

Pressure setup

To raise the pressure, the feed crane is used, and in order to drop the pressure - the trigger valve.

The optimal value is the range of 0.7-1 mbar. Usually boilers Baxi independently support the desired valueBut sometimes there are failures. If a constant drop is observed, which does not disappear after feeding the system, it means somewhere the leakage occurs.

This can mean either leakage of pipelines or radiators, a system of underfloor or other external elements.

Often the problem arises due to a trigger malfunction. An abnormal increase in pressure may be due to a malfunction or an open tap of feeding or damage to the expansion tank membrane.

Optimal mode of operation

The optimal mode of the boiler is described in detail in the user manual.

His parameters:

  • Temperature s - 70-75 °.
  • Water pressure is 0.7-1 mbar.
  • The parameters F08 and F10 are configured according to the minimum and maximum value.

The setting is performed during commissioning, additional adjustments are performed periodically during the annual maintenance or after repair work.

Self-Diagnosis

Self-diagnosis is an automatic continuous process that runs immediately when the boiler is first turned on.

It does not require any special actions and passes constantly in the background. Any error is immediately recorded by the corresponding sensor, which displays it to the display, and the control board blocks the operation of the unit. To reset the error and restart the boiler, click the "R" button and hold it for a few seconds.

Basic error codes and their decoding

Baxi (buxi) boiler errors are certain deviations from the nominal mode of operation, which are fixed by the sensors and are issued on the unit in the form of a numeric code with the letter E (ERROR).

Consider them carefully:

Error code Type of malfunction Decision
E01-02 Lack of heat carrier in the system (failure of the duct sensor) System feeding, sensor replacement
E03 No flame Practitioners nozzles, gas supply, repair system
E04 False evidence of the presence of a flame (breaking spark on the sensor) Removal of water drops from fees, insulation or sensor replacement
E05 Open temperature sensor Restoration of contact
E06 CZ temperature sensor Replacing the sensor
E07 DHW Temperature Sensor Open Restoration of contact
E08. KZ DHW temperature sensor Replacing the sensor
E09 Failure fan Repair or Replacement Device
E10. Failure to work smoke Cleaning the chimney, restoring the working state of the smoke
E13 Kz duct sensor Replacing the sensor
E15 Malfunction or refusal of control board Repair or Replacing the Board
E16 Exceeding permissible temperature Heating boiler Cleaning the heat exchanger from scale, feeding the system with water
E18 Overheating sensor smoke removal Repair or sensor replacement
E27 KZ or air pressure slope Replacing the sensor

Useful video

Read more in detail how to connect, configure and run this boiler you can in this video:

Conclusion

Carefulness and quality settings of boacies boils ensure the efficiency and durability of the equipment and the entire heating system as a whole.

The boiler operation largely depends on the gas supply mode and the specified temperature range, which, in turn, are selected on the basis of the climatic characteristics of the region and the size of the heat loss.

The main condition is the accuracy of the execution of adjustments, the absence of frequent and unskilled interference with the operation of the unit.

Competently completed setting to ensure the durability of the equipment and a comfortable microclimate indoor.

In contact with

Dynamic development construction technologies Allows many of our citizens to acquire own home Outside the city. Enjoy a small cottage or cottage becomes the norm. To live away from a noisy megalopolis, enjoy clean air and peace - that's what attracts people.

IN country house, dacha or cottage is usually missing central heating and the supply of hot water. This makes it impossible to constantly comfortable stay in such a house in winter. Without full heating in the cold time, the decision will be autonomous system Heating.

Independent heating system

Autonomous heating does not depend on heat networks. And this is perhaps the main dignity. You can adjust the temperature in the room yourself, and if necessary, turn off the heating at all. On average for 5 years equipment for autonomous heating Fully pays off.

Comfort, efficiency and reliability of housing is dependent on the choice of boiler. If your home is in a gasified area, it makes sense to acquire a gas boiler.

Types of boilers

Provide hot water The house is designed by a flow gas heater. He was installed earlier in apartment house. Now the models are improved and equipped with a gas control system and ignition.

Single-mounted gas boiler uses a small area for heating housing. It is simple, powerful, but its operation has its own characteristics:

  • the need to connect to chimney;
  • use for combustion of indoor indoor air (open combustion chamber);
  • the need for additional ventilation of the room.

The boiler with an open combustion chamber requires increased caution and strict adherence to fire and sanitary requirements. Among one-contacts there are boilers with a closed combustion chamber, but they are more expensive.

A double-circuit gas boiler is capable not only to heat the room, but also heat the water. One contour works for water heated, and the second is for heating.

Wall gas boilers "Baksy"

Construction and design of Italian gas boilers meet the needs modern heating. Gas boiler "Baksy Moon" can be positioned on any free place walls. He does not require a special premises for accommodation - everything that he needs for work is already provided for in the inner structure.

Mandatory certification for compliance with the safety requirements are all wall gas boilers "Baksy". Consumer reviews most often confirm the simplicity of boiler management and its safety.

The aggregates are equipped with a special system of control, which is capable of diagnosing system operation itself and take into account weather conditions. If there is a gas pressure drop in the main entrance, it will not affect the operation of the gas boiler.

Assortment of wall gas boilers "Buckuck"

  • Gas single-mounted boiler - only for heating at home.
  • Household wall gas boiler with two contours; Purpose - heating and hot water supply.
  • Turbated boiler with two contours. Special equipment Increases the rate of internal processes - for heating and hot water supply.
  • The gas wall uses the released steam energy until it is transition to water.

Wall boilers with one contour

Single-mounted gas boilers are designed for heating at the house. Wall-mounted "Baksy" decided to make more functional and installed special taps for installing an additional boiler. It is possible to heat the water for household needs.

Single-mounted boilers are pretty simple. The burner, which sets up gas, placed inside a safe thermal shell. The heat that accumulates in the combustion chamber, through the heat exchanger is transmitted to the heating circuit.

Material for the manufacture of the heat exchanger is copper, cast iron or steel. This type of boilers is designed for a small power - from 14 to 31 kW. Wall-mounted Baxi Small in size, manufactured with a closed or open camera.

Double-circuit wall gas boilers

The design of the boiler provides for the presence of a heat exchanger that is connected to the heating system. Water heating occurs once in a closed cycle. On the heat exchanger, you only need to maintain the required temperature.

The heat exchanger that is connected to the water heating system, the secondary, and the new portion arrives in it periodically cold water, so he is forced to work constantly for heating.

Types of heat exchangers on "Baksy" boilers:

  • Lamellar. A long curved steel tube is attacked to protect the design from high temperature, a special protective layer was applied to it.
  • Biometric. Another pipe smaller diameter is inserted inside the pipe. In the outer water flows for heating, water for household needs is moving along the inner.

Gas boiler Baxi Luna 3 Comfort

Perhaps the most popular and perfect is a double-circuit gas wall-mounted boiler "Baksy". Reviews, in any case, it is that. The model is considered successful and reliable. There are several reasons for this:

  • Installed weather-dependent automatic system.
  • Temperature regime for heating radiators (30-85 ° C) and separately - for water heating floor (30-45 ° C).
  • Self-diagnosis with the memory of recent problems and failures in work.
  • The liquid crystal display reflects all the necessary operating parameters.
  • An anti-corrosion coating is applied to the heat exchanger.

Wall double-circuit turbine boilers

The use of such boilers provides significant blue fuel savings. Turbocads are built into the system, and this allows you to get the necessary amount of heat at a lower gas consumption. The fan is additionally installed in the boiler, which injected the air from the street.

Cold air falls along a pipe built into another, larger diameterwhich works on the output of combustion products. The design is completely sealed and eliminates the hitting of harmful toxins and gary inside the room.

Condensation wall boilers

The principle of their work is based on the laws of physics. Usually in the chamber of the boiler burns gas, and combustion products are outward. In a condensation, a slightly different procedure.

When combustion, carbon is formed its dioxide and water vapor. The installed heat exchanger cools the steam, and the energy separated uses to heat the contours. Its efficiency significantly exceeds the indicators of simple gas boilers.

Advantages of wall-mounted boilers for consumer reviews

  • Boats "Buckuck" with two contours with all their small size are able to cope with the heating of the room and the heating of the water in uninterrupted mode.
  • Water heating occurs in protocal mode, and not in a boiler room. It is much more convenient and economically.
  • The boiler is fully working in automatic mode. The user does not need to spend time to control the workflow of the boiler.
  • By choosing a wall gas boiler "Baksy", you do not need to buy related equipment. All that is necessary for the autonomous work of the boiler is provided by its design.
  • The size of the unit is minimal. It does not take a lot of space, so it is more often installed in the kitchen, where it coincides with the size of the wall cabinets.
  • If the Gas boiler "Baksy" is correctly installed, the error in its work is almost excluded. It is reliable, effective, safe and relatively inexpensive.

The main characteristics of the wall gas boilers "Baksy"

  • Permanent flame modulation occurs. It increases efficiency and saves gas.
  • In winter, when low temperatures, with a decrease in gas pressure up to 5 mbar, the device works smoothly.
  • Enough to change the gyps and re-set the gas - and it will go with natural Gas on liquefied.
  • Stainless steel used for burner material, and this significantly increased their service life.
  • Installed filter at the inlet for cold water.
  • You can install a room thermostat or modes programmer.
  • Limit pressure in the heating system - 3 bar, in the DHW circuit - 8 bar.

Gas floor boilers "Baksy"

A large range and optimal consumer properties are distinguished by buxi gas boilers. Reviews of owners who have installed outdoor option Boilers, testify to their uninterrupted performance. And this is due to excellent quality their execution.

Gas flooring boilers "Baksy" have a built-in self-diagnostic electronic system, which controls the operating parameters and, if necessary, adjusts them in the event of a pressure drop in the highway.

Fully autonomous, without any intervention, the bucky gas boiler works. Errors in the operation of the boiler or a decrease in pressure in the pipeline lead to the operational shutdown of gas supply to the burner.

Outdoor boilers are produced in several versions. You can pick up your homes, cottages or production premiseswhere it is necessary to maintain a constant temperature, the most suitable gas floor boiler "Baksy". Owners say that errors are practically excluded when connected, the models are extremely simple. Specialists in installing aggregates will argue them for the needs of the homeowner.

Assortment of outdoor gas boilers "Baksy":

  • Single-mounted boilers.
  • Double-circuit boilers.
  • Atmospheric boilers.
  • Condensation boilers.

Condensation Gas boilers "Baksy"

The principle of operation is the same as the wall boilers. The heat exchanger undergoes the process of reverse transformation of the dispersed part into the liquid. In the transition, the release of additional energy occurs, which at times increases the energy intensity of the boiler.

Atmospheric floor boilers with one contour

In the gas boiler "Baksy" for the ignition of the burner is provided by a separate source. The aggregates are used in different conditions. To increase the safety of the aggregate, made an atmospheric gas boiler "Baksy". The instruction prescribes to install it in a place where it is possible to connect the chimney, a gas pipe, heating and water supply systems.

IN atmospheric boilers Thermocouple controls uninterrupted work Products. The dependence of the boiler from energy carriers is excluded, and if the burner flame went out, the intake valve is closed. Such a device was able to improve the safety of the gas boiler operation.

Atmospheric floor boilers with two contours

Gas flooring boilers, having two independent contours, warm the house and prepare hot water. Thermal energywhich is generated is spent on maintaining the already obtained heat transfer regime. The periodic flow of cold portions of water makes the boiler constantly work for heating.

Gas boiler "Bacci Slim"

Copper gas "bucky Slim" Compact, independent of electricity. Made from cast iron, has an atmospheric burner and automation that will protect the use of the unit, breaking the gas valve. In the model line boiler, the gas "bucki slim" is represented by the 5th species. They differ in power.

Problems are possible, which are out of order of the bucky gas boiler. Installation instructions should always be observed.

There may be problems with the boiler when installing an incorrectly selected chimney. Profile experts insist on the installation of a coaxcal chimney, which also produces Baksy firm.

However, if you already have a proven reliable chimney, and you have no doubt about it, it is possible to connect to it. This will somewhat save the cash holder.

Easy to serve gas boilers "Buckucky Slim." User feedback indicate that if you need to clean any compartment of the unit, it can be done independently without resorting to the services of professionals.

You can easily customize the bucky gas boiler. Managing instructions are simple, and the information liquid crystal board will give an exhaustive picture of the settings. Power consumer can set himself, it is necessary to set the right program and set the necessary minimum and maximum values.

A self-diagnostic system is built into the bucky gas boiler. He himself can not only reveal the breakdown, but also eliminate in a short time. The display shows all information to adjust and set pressure in the system and the water temperature.

Safe and reliable gas boilers "Baksy". Consumer reviews

Any technique is subject to breakdowns, but everything compares in percentage ratio. Judging by the reviews of the owners, Gas boilers "Baksy" have the quality, ease of control, fully automated and do not require complex maintenance.

Complaints if they arise, then the breakdowns are insignificant and they do not always occur due to the poor performance of the boiler itself. It is necessary to monitor the chimney so that it is possible to scale on the heat exchanger possible, but this can also be quickly corrected.

Instructions for choosing a bucky gas boiler "

  • Be sure to ask the warranty period that is issued when buying a boiler.
  • The wall boiler with a capacity of 11-42 kW is suitable for heating at home with an area of \u200b\u200bup to 400 square meters. m. For the price it will be almost half cheaper than the outdoor. This is due to the design of the boiler.
  • If the cottage is allowed, and the boiler can be installed in a separate room, the choice can be stopped on boilers with an open combustion chamber.
  • Closed boiler combustion chamber is designed for residential rooms. Oxygen fence occurs through a coxic chimney. Forced or additional ventilation is not required.
  • The turbocharged gas boiler is environmentally friendly and economical, it can be installed in closed rooms.
  • If the house is planned to regularly use a bath, a bidet, a kitchen sink - a choice for a boiler with two contours.
  • If the project is more than one bathroom, then a single-mounted boiler is needed and an additional boiler installation.
  • Outdoor boilers have a greater margin of safety, they are more durable, more powerful and more productive. To install such a boiler, a special room will be required.
  • Due to the long service life, it is necessary to approach the installation of the boiler itself more responsibly.

Italian gas boilers "Baksy" reviews with positive estimates from users get regularly. They have proven themselves in the market safe, productive and environmentally friendly, possess modern design and high-tech automatics, fully justify the expectations of buyers and do not disappoint the demanding users.